Inter-user comparison for quantification of superparamagnetic iron oxides with magnetic particle imaging across two institutions highlights a need for standardized approaches
PURPOSE: Magnetic particle imaging (MPI) is being explored in biological contexts that require accurate and reproducible quantification of superparamagnetic iron oxide nanoparticles (SPIONs). While many groups have focused on improving imager and SPION design to improve resolution and sensitivity, f...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cold Spring Harbor Laboratory
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10104026/ https://www.ncbi.nlm.nih.gov/pubmed/37066180 http://dx.doi.org/10.1101/2023.04.03.535446 |
_version_ | 1785025957473550336 |
---|---|
author | Good, Hayden J. Sehl, Olivia C. Gevaert, Julia J. Yu, Bo Berih, Maryam A. Montero, Sebastian A. Rinaldi-Ramos, Carlos M. Foster, Paula J. |
author_facet | Good, Hayden J. Sehl, Olivia C. Gevaert, Julia J. Yu, Bo Berih, Maryam A. Montero, Sebastian A. Rinaldi-Ramos, Carlos M. Foster, Paula J. |
author_sort | Good, Hayden J. |
collection | PubMed |
description | PURPOSE: Magnetic particle imaging (MPI) is being explored in biological contexts that require accurate and reproducible quantification of superparamagnetic iron oxide nanoparticles (SPIONs). While many groups have focused on improving imager and SPION design to improve resolution and sensitivity, few have focused on improving quantification and reproducibility of MPI. The aim of this study was to compare MPI quantification results by two different systems and the accuracy of SPION quantification performed by multiple users at two institutions. PROCEDURES: Six users (3 from each institute) imaged a known amount of Vivotrax+ (10 μg Fe), diluted in a small (10 μL) or large (500 μL) volume. These samples were imaged with or without calibration standards in the field of view, to create a total of 72 images (6 users × triplicate samples × 2 sample volumes × 2 calibration methods). These images were analyzed by the respective user with two region of interest (ROI) selection methods. Image intensities, Vivotrax+ quantification, and ROI selection was compared across users, within and across institutions. RESULTS: MPI imagers at two different institutes produce significantly different signal intensities, that differ by over 3 times for the same concentration of Vivotrax+. Overall quantification yielded measurements that were within ± 20% from ground truth, however SPION quantification values obtained at each laboratory were significantly different. Results suggest that the use of different imagers had a stronger influence on SPION quantification compared to differences arising from user error. Lastly, calibration conducted from samples in the imaging field of view gave the same quantification results as separately imaged samples. CONCLUSIONS: This study highlights that there are many factors that contribute to the accuracy and reproducibility of MPI quantification, including variation between MPI imagers and users, despite pre-defined experimental set up, image acquisition parameters, and ROI selection analysis. |
format | Online Article Text |
id | pubmed-10104026 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Cold Spring Harbor Laboratory |
record_format | MEDLINE/PubMed |
spelling | pubmed-101040262023-04-15 Inter-user comparison for quantification of superparamagnetic iron oxides with magnetic particle imaging across two institutions highlights a need for standardized approaches Good, Hayden J. Sehl, Olivia C. Gevaert, Julia J. Yu, Bo Berih, Maryam A. Montero, Sebastian A. Rinaldi-Ramos, Carlos M. Foster, Paula J. bioRxiv Article PURPOSE: Magnetic particle imaging (MPI) is being explored in biological contexts that require accurate and reproducible quantification of superparamagnetic iron oxide nanoparticles (SPIONs). While many groups have focused on improving imager and SPION design to improve resolution and sensitivity, few have focused on improving quantification and reproducibility of MPI. The aim of this study was to compare MPI quantification results by two different systems and the accuracy of SPION quantification performed by multiple users at two institutions. PROCEDURES: Six users (3 from each institute) imaged a known amount of Vivotrax+ (10 μg Fe), diluted in a small (10 μL) or large (500 μL) volume. These samples were imaged with or without calibration standards in the field of view, to create a total of 72 images (6 users × triplicate samples × 2 sample volumes × 2 calibration methods). These images were analyzed by the respective user with two region of interest (ROI) selection methods. Image intensities, Vivotrax+ quantification, and ROI selection was compared across users, within and across institutions. RESULTS: MPI imagers at two different institutes produce significantly different signal intensities, that differ by over 3 times for the same concentration of Vivotrax+. Overall quantification yielded measurements that were within ± 20% from ground truth, however SPION quantification values obtained at each laboratory were significantly different. Results suggest that the use of different imagers had a stronger influence on SPION quantification compared to differences arising from user error. Lastly, calibration conducted from samples in the imaging field of view gave the same quantification results as separately imaged samples. CONCLUSIONS: This study highlights that there are many factors that contribute to the accuracy and reproducibility of MPI quantification, including variation between MPI imagers and users, despite pre-defined experimental set up, image acquisition parameters, and ROI selection analysis. Cold Spring Harbor Laboratory 2023-04-05 /pmc/articles/PMC10104026/ /pubmed/37066180 http://dx.doi.org/10.1101/2023.04.03.535446 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which allows reusers to copy and distribute the material in any medium or format in unadapted form only, for noncommercial purposes only, and only so long as attribution is given to the creator. |
spellingShingle | Article Good, Hayden J. Sehl, Olivia C. Gevaert, Julia J. Yu, Bo Berih, Maryam A. Montero, Sebastian A. Rinaldi-Ramos, Carlos M. Foster, Paula J. Inter-user comparison for quantification of superparamagnetic iron oxides with magnetic particle imaging across two institutions highlights a need for standardized approaches |
title | Inter-user comparison for quantification of superparamagnetic iron oxides with magnetic particle imaging across two institutions highlights a need for standardized approaches |
title_full | Inter-user comparison for quantification of superparamagnetic iron oxides with magnetic particle imaging across two institutions highlights a need for standardized approaches |
title_fullStr | Inter-user comparison for quantification of superparamagnetic iron oxides with magnetic particle imaging across two institutions highlights a need for standardized approaches |
title_full_unstemmed | Inter-user comparison for quantification of superparamagnetic iron oxides with magnetic particle imaging across two institutions highlights a need for standardized approaches |
title_short | Inter-user comparison for quantification of superparamagnetic iron oxides with magnetic particle imaging across two institutions highlights a need for standardized approaches |
title_sort | inter-user comparison for quantification of superparamagnetic iron oxides with magnetic particle imaging across two institutions highlights a need for standardized approaches |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10104026/ https://www.ncbi.nlm.nih.gov/pubmed/37066180 http://dx.doi.org/10.1101/2023.04.03.535446 |
work_keys_str_mv | AT goodhaydenj interusercomparisonforquantificationofsuperparamagneticironoxideswithmagneticparticleimagingacrosstwoinstitutionshighlightsaneedforstandardizedapproaches AT sehloliviac interusercomparisonforquantificationofsuperparamagneticironoxideswithmagneticparticleimagingacrosstwoinstitutionshighlightsaneedforstandardizedapproaches AT gevaertjuliaj interusercomparisonforquantificationofsuperparamagneticironoxideswithmagneticparticleimagingacrosstwoinstitutionshighlightsaneedforstandardizedapproaches AT yubo interusercomparisonforquantificationofsuperparamagneticironoxideswithmagneticparticleimagingacrosstwoinstitutionshighlightsaneedforstandardizedapproaches AT berihmaryama interusercomparisonforquantificationofsuperparamagneticironoxideswithmagneticparticleimagingacrosstwoinstitutionshighlightsaneedforstandardizedapproaches AT monterosebastiana interusercomparisonforquantificationofsuperparamagneticironoxideswithmagneticparticleimagingacrosstwoinstitutionshighlightsaneedforstandardizedapproaches AT rinaldiramoscarlosm interusercomparisonforquantificationofsuperparamagneticironoxideswithmagneticparticleimagingacrosstwoinstitutionshighlightsaneedforstandardizedapproaches AT fosterpaulaj interusercomparisonforquantificationofsuperparamagneticironoxideswithmagneticparticleimagingacrosstwoinstitutionshighlightsaneedforstandardizedapproaches |