Consistency of serial ultrasonographic joint tissue measurements by the Joint (tissue)Activity and Damage Exam (JADE) protocol in relation to hemophilic joint health parameters

OBJECTIVES: The Joint (tissue)Activity and Damage Exam (JADE) is a point-of-care (POC) musculoskeletal ultrasound (MSKUS) protocol for non-radiologists to evaluate hemophilic arthopathy. Our aim was to determine the consistency of cross-sectional analyses of direct tissue measurements (JADE protocol...

Descripción completa

Detalles Bibliográficos
Autores principales: Barnes, Richard F. W., Aguero, Peter, Hanacek, Cris, Flores, Andres, Steiner, Bruno, Bailey, Cindy, Quon, Doris V., Kruse-Jarres, Rebecca, von Drygalski, Annette
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10105411/
https://www.ncbi.nlm.nih.gov/pubmed/37061676
http://dx.doi.org/10.1186/s12891-023-06419-5
_version_ 1785026205562437632
author Barnes, Richard F. W.
Aguero, Peter
Hanacek, Cris
Flores, Andres
Steiner, Bruno
Bailey, Cindy
Quon, Doris V.
Kruse-Jarres, Rebecca
von Drygalski, Annette
author_facet Barnes, Richard F. W.
Aguero, Peter
Hanacek, Cris
Flores, Andres
Steiner, Bruno
Bailey, Cindy
Quon, Doris V.
Kruse-Jarres, Rebecca
von Drygalski, Annette
author_sort Barnes, Richard F. W.
collection PubMed
description OBJECTIVES: The Joint (tissue)Activity and Damage Exam (JADE) is a point-of-care (POC) musculoskeletal ultrasound (MSKUS) protocol for non-radiologists to evaluate hemophilic arthopathy. Our aim was to determine the consistency of cross-sectional analyses of direct tissue measurements (JADE protocol) and clinical Hemophilia Joint Health Score [HJHS] and functional joint assessments (arc) at three clinic visits. METHODS: We prospectively studied adults (n = 44) with hemophilia (A or B) of any severity and arthropathy at 3 North American sites. We assessed HJHS, total arc, and JADE parameters (bilateral elbows, ankles, and knees) at study entry, at ≈12–18 months, and at ≈24–36 months, and used MSKUS to evaluate painful episodes between study visits. JADE measurements included osteochondral alterations, cartilage thickness, and soft tissue expansion at sentinel positions. Associations between joint HJHS and total arc with each JADE variable were examined with random intercept models. RESULTS: At each visit increasing HJHS and decreasing total arc were associated in the expected direction with increasing length of OAs and soft tissue expansion in all joints, and decreasing cartilage thickness in the knee. However, HJHS associations with cartilage thickness were U-shaped for elbow and ankle (i.e. cartilage thinning and thickening). Associations between total arc and cartilage thickness followed a similar curve. (Near) normal levels of both joint parameters (HJHS and total arc) were associated with normal ranges of cartilage thickness. JADE views were also helpful to detect hemarthrosis in association with joint pains. CONCLUSIONS: POC MSKUS applying direct tissue measurements using the JADE protocol provided reproducible cross-sectional associations with joint health outcomes on three visits. These findings advance protocol validation and enable iterative adaptations resulting in JADE protocol version 2. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-023-06419-5.
format Online
Article
Text
id pubmed-10105411
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-101054112023-04-16 Consistency of serial ultrasonographic joint tissue measurements by the Joint (tissue)Activity and Damage Exam (JADE) protocol in relation to hemophilic joint health parameters Barnes, Richard F. W. Aguero, Peter Hanacek, Cris Flores, Andres Steiner, Bruno Bailey, Cindy Quon, Doris V. Kruse-Jarres, Rebecca von Drygalski, Annette BMC Musculoskelet Disord Research OBJECTIVES: The Joint (tissue)Activity and Damage Exam (JADE) is a point-of-care (POC) musculoskeletal ultrasound (MSKUS) protocol for non-radiologists to evaluate hemophilic arthopathy. Our aim was to determine the consistency of cross-sectional analyses of direct tissue measurements (JADE protocol) and clinical Hemophilia Joint Health Score [HJHS] and functional joint assessments (arc) at three clinic visits. METHODS: We prospectively studied adults (n = 44) with hemophilia (A or B) of any severity and arthropathy at 3 North American sites. We assessed HJHS, total arc, and JADE parameters (bilateral elbows, ankles, and knees) at study entry, at ≈12–18 months, and at ≈24–36 months, and used MSKUS to evaluate painful episodes between study visits. JADE measurements included osteochondral alterations, cartilage thickness, and soft tissue expansion at sentinel positions. Associations between joint HJHS and total arc with each JADE variable were examined with random intercept models. RESULTS: At each visit increasing HJHS and decreasing total arc were associated in the expected direction with increasing length of OAs and soft tissue expansion in all joints, and decreasing cartilage thickness in the knee. However, HJHS associations with cartilage thickness were U-shaped for elbow and ankle (i.e. cartilage thinning and thickening). Associations between total arc and cartilage thickness followed a similar curve. (Near) normal levels of both joint parameters (HJHS and total arc) were associated with normal ranges of cartilage thickness. JADE views were also helpful to detect hemarthrosis in association with joint pains. CONCLUSIONS: POC MSKUS applying direct tissue measurements using the JADE protocol provided reproducible cross-sectional associations with joint health outcomes on three visits. These findings advance protocol validation and enable iterative adaptations resulting in JADE protocol version 2. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-023-06419-5. BioMed Central 2023-04-15 /pmc/articles/PMC10105411/ /pubmed/37061676 http://dx.doi.org/10.1186/s12891-023-06419-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Barnes, Richard F. W.
Aguero, Peter
Hanacek, Cris
Flores, Andres
Steiner, Bruno
Bailey, Cindy
Quon, Doris V.
Kruse-Jarres, Rebecca
von Drygalski, Annette
Consistency of serial ultrasonographic joint tissue measurements by the Joint (tissue)Activity and Damage Exam (JADE) protocol in relation to hemophilic joint health parameters
title Consistency of serial ultrasonographic joint tissue measurements by the Joint (tissue)Activity and Damage Exam (JADE) protocol in relation to hemophilic joint health parameters
title_full Consistency of serial ultrasonographic joint tissue measurements by the Joint (tissue)Activity and Damage Exam (JADE) protocol in relation to hemophilic joint health parameters
title_fullStr Consistency of serial ultrasonographic joint tissue measurements by the Joint (tissue)Activity and Damage Exam (JADE) protocol in relation to hemophilic joint health parameters
title_full_unstemmed Consistency of serial ultrasonographic joint tissue measurements by the Joint (tissue)Activity and Damage Exam (JADE) protocol in relation to hemophilic joint health parameters
title_short Consistency of serial ultrasonographic joint tissue measurements by the Joint (tissue)Activity and Damage Exam (JADE) protocol in relation to hemophilic joint health parameters
title_sort consistency of serial ultrasonographic joint tissue measurements by the joint (tissue)activity and damage exam (jade) protocol in relation to hemophilic joint health parameters
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10105411/
https://www.ncbi.nlm.nih.gov/pubmed/37061676
http://dx.doi.org/10.1186/s12891-023-06419-5
work_keys_str_mv AT barnesrichardfw consistencyofserialultrasonographicjointtissuemeasurementsbythejointtissueactivityanddamageexamjadeprotocolinrelationtohemophilicjointhealthparameters
AT agueropeter consistencyofserialultrasonographicjointtissuemeasurementsbythejointtissueactivityanddamageexamjadeprotocolinrelationtohemophilicjointhealthparameters
AT hanacekcris consistencyofserialultrasonographicjointtissuemeasurementsbythejointtissueactivityanddamageexamjadeprotocolinrelationtohemophilicjointhealthparameters
AT floresandres consistencyofserialultrasonographicjointtissuemeasurementsbythejointtissueactivityanddamageexamjadeprotocolinrelationtohemophilicjointhealthparameters
AT steinerbruno consistencyofserialultrasonographicjointtissuemeasurementsbythejointtissueactivityanddamageexamjadeprotocolinrelationtohemophilicjointhealthparameters
AT baileycindy consistencyofserialultrasonographicjointtissuemeasurementsbythejointtissueactivityanddamageexamjadeprotocolinrelationtohemophilicjointhealthparameters
AT quondorisv consistencyofserialultrasonographicjointtissuemeasurementsbythejointtissueactivityanddamageexamjadeprotocolinrelationtohemophilicjointhealthparameters
AT krusejarresrebecca consistencyofserialultrasonographicjointtissuemeasurementsbythejointtissueactivityanddamageexamjadeprotocolinrelationtohemophilicjointhealthparameters
AT vondrygalskiannette consistencyofserialultrasonographicjointtissuemeasurementsbythejointtissueactivityanddamageexamjadeprotocolinrelationtohemophilicjointhealthparameters