Eliminating transseptal sheath exchange for pulsed field ablation procedures using a direct over-the-needle transseptal access with the Faradrive sheath
AIMS: Pulsed field ablation (PFA) for pulmonary vein isolation (PVI) combines the benefits of high procedural efficacy and safety. Transseptal puncture (TSP) to obtain left atrial (LA) access during PVI remains an important source of complications during LA procedures. For PFA procedures, TSP is gen...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10105838/ https://www.ncbi.nlm.nih.gov/pubmed/36892147 http://dx.doi.org/10.1093/europace/euad060 |
_version_ | 1785026295998971904 |
---|---|
author | Kueffer, Thomas Madaffari, Antonio Thalmann, Gregor Mühl, Aline Galuszka, Oskar Baldinger, Samuel Seiler, Jens Tanner, Hildegard Kobza, Richard Roten, Laurent Berte, Benjamin Reichlin, Tobias |
author_facet | Kueffer, Thomas Madaffari, Antonio Thalmann, Gregor Mühl, Aline Galuszka, Oskar Baldinger, Samuel Seiler, Jens Tanner, Hildegard Kobza, Richard Roten, Laurent Berte, Benjamin Reichlin, Tobias |
author_sort | Kueffer, Thomas |
collection | PubMed |
description | AIMS: Pulsed field ablation (PFA) for pulmonary vein isolation (PVI) combines the benefits of high procedural efficacy and safety. Transseptal puncture (TSP) to obtain left atrial (LA) access during PVI remains an important source of complications during LA procedures. For PFA procedures, TSP is generally performed using a standard transseptal sheath that is then exchanged over the wire for a dedicated PFA sheath, which might be a potential source for air embolism. We aimed to prospectively evaluate the feasibility and safety of a simplified workflow using the PFA sheath (Faradrive, Boston Scientific) directly for TSP. METHODS AND RESULTS: We prospectively enrolled 100 patients undergoing PVI using PFA at two centres. TSP was performed using the PFA sheath and a standard 98 cm transseptal needle under fluoroscopic guidance. TSP via the PFA sheath was successfully performed in all patients and no complications occurred. The median time from the first groin puncture to the completed LA access was 12 min (IQR 8–16 min). CONCLUSION: An over-the-needle TSP directly with the PFA sheath proved feasible and safe in our study. This simplified workflow has the potential to reduce the risk of air embolism, to shorten procedure time, and to reduce cost. |
format | Online Article Text |
id | pubmed-10105838 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-101058382023-04-17 Eliminating transseptal sheath exchange for pulsed field ablation procedures using a direct over-the-needle transseptal access with the Faradrive sheath Kueffer, Thomas Madaffari, Antonio Thalmann, Gregor Mühl, Aline Galuszka, Oskar Baldinger, Samuel Seiler, Jens Tanner, Hildegard Kobza, Richard Roten, Laurent Berte, Benjamin Reichlin, Tobias Europace Technical Issues AIMS: Pulsed field ablation (PFA) for pulmonary vein isolation (PVI) combines the benefits of high procedural efficacy and safety. Transseptal puncture (TSP) to obtain left atrial (LA) access during PVI remains an important source of complications during LA procedures. For PFA procedures, TSP is generally performed using a standard transseptal sheath that is then exchanged over the wire for a dedicated PFA sheath, which might be a potential source for air embolism. We aimed to prospectively evaluate the feasibility and safety of a simplified workflow using the PFA sheath (Faradrive, Boston Scientific) directly for TSP. METHODS AND RESULTS: We prospectively enrolled 100 patients undergoing PVI using PFA at two centres. TSP was performed using the PFA sheath and a standard 98 cm transseptal needle under fluoroscopic guidance. TSP via the PFA sheath was successfully performed in all patients and no complications occurred. The median time from the first groin puncture to the completed LA access was 12 min (IQR 8–16 min). CONCLUSION: An over-the-needle TSP directly with the PFA sheath proved feasible and safe in our study. This simplified workflow has the potential to reduce the risk of air embolism, to shorten procedure time, and to reduce cost. Oxford University Press 2023-03-09 /pmc/articles/PMC10105838/ /pubmed/36892147 http://dx.doi.org/10.1093/europace/euad060 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Technical Issues Kueffer, Thomas Madaffari, Antonio Thalmann, Gregor Mühl, Aline Galuszka, Oskar Baldinger, Samuel Seiler, Jens Tanner, Hildegard Kobza, Richard Roten, Laurent Berte, Benjamin Reichlin, Tobias Eliminating transseptal sheath exchange for pulsed field ablation procedures using a direct over-the-needle transseptal access with the Faradrive sheath |
title | Eliminating transseptal sheath exchange for pulsed field ablation procedures using a direct over-the-needle transseptal access with the Faradrive sheath |
title_full | Eliminating transseptal sheath exchange for pulsed field ablation procedures using a direct over-the-needle transseptal access with the Faradrive sheath |
title_fullStr | Eliminating transseptal sheath exchange for pulsed field ablation procedures using a direct over-the-needle transseptal access with the Faradrive sheath |
title_full_unstemmed | Eliminating transseptal sheath exchange for pulsed field ablation procedures using a direct over-the-needle transseptal access with the Faradrive sheath |
title_short | Eliminating transseptal sheath exchange for pulsed field ablation procedures using a direct over-the-needle transseptal access with the Faradrive sheath |
title_sort | eliminating transseptal sheath exchange for pulsed field ablation procedures using a direct over-the-needle transseptal access with the faradrive sheath |
topic | Technical Issues |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10105838/ https://www.ncbi.nlm.nih.gov/pubmed/36892147 http://dx.doi.org/10.1093/europace/euad060 |
work_keys_str_mv | AT kuefferthomas eliminatingtransseptalsheathexchangeforpulsedfieldablationproceduresusingadirectovertheneedletransseptalaccesswiththefaradrivesheath AT madaffariantonio eliminatingtransseptalsheathexchangeforpulsedfieldablationproceduresusingadirectovertheneedletransseptalaccesswiththefaradrivesheath AT thalmanngregor eliminatingtransseptalsheathexchangeforpulsedfieldablationproceduresusingadirectovertheneedletransseptalaccesswiththefaradrivesheath AT muhlaline eliminatingtransseptalsheathexchangeforpulsedfieldablationproceduresusingadirectovertheneedletransseptalaccesswiththefaradrivesheath AT galuszkaoskar eliminatingtransseptalsheathexchangeforpulsedfieldablationproceduresusingadirectovertheneedletransseptalaccesswiththefaradrivesheath AT baldingersamuel eliminatingtransseptalsheathexchangeforpulsedfieldablationproceduresusingadirectovertheneedletransseptalaccesswiththefaradrivesheath AT seilerjens eliminatingtransseptalsheathexchangeforpulsedfieldablationproceduresusingadirectovertheneedletransseptalaccesswiththefaradrivesheath AT tannerhildegard eliminatingtransseptalsheathexchangeforpulsedfieldablationproceduresusingadirectovertheneedletransseptalaccesswiththefaradrivesheath AT kobzarichard eliminatingtransseptalsheathexchangeforpulsedfieldablationproceduresusingadirectovertheneedletransseptalaccesswiththefaradrivesheath AT rotenlaurent eliminatingtransseptalsheathexchangeforpulsedfieldablationproceduresusingadirectovertheneedletransseptalaccesswiththefaradrivesheath AT bertebenjamin eliminatingtransseptalsheathexchangeforpulsedfieldablationproceduresusingadirectovertheneedletransseptalaccesswiththefaradrivesheath AT reichlintobias eliminatingtransseptalsheathexchangeforpulsedfieldablationproceduresusingadirectovertheneedletransseptalaccesswiththefaradrivesheath |