Cargando…

Comparison between supine and prone patient setup for lumbosacral spinal stereotactic body radiosurgery with CyberKnife

OBJECTIVE: The aim of this study is to analyze which tracking modality is more suitable for stereotactic body radiosurgery of lumbosacral spinal tumors by comparing prone and supine patient treatment setup. METHODS: Eighteen patients with lumbosacral spinal tumors were selected. CT simulation was pe...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Jun, Kong, Xianghui, cheng, Cheng, Wang, Gong, Zhuang, Hongqing, Yang, Ruijie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10106579/
https://www.ncbi.nlm.nih.gov/pubmed/37077832
http://dx.doi.org/10.3389/fonc.2023.959447
_version_ 1785026432713359360
author Li, Jun
Kong, Xianghui
cheng, Cheng
Wang, Gong
Zhuang, Hongqing
Yang, Ruijie
author_facet Li, Jun
Kong, Xianghui
cheng, Cheng
Wang, Gong
Zhuang, Hongqing
Yang, Ruijie
author_sort Li, Jun
collection PubMed
description OBJECTIVE: The aim of this study is to analyze which tracking modality is more suitable for stereotactic body radiosurgery of lumbosacral spinal tumors by comparing prone and supine patient treatment setup. METHODS: Eighteen patients with lumbosacral spinal tumors were selected. CT simulation was performed in the supine position (fixed with a vacuum cushion) and prone position (fixed with a thermoplastic mask and prone plate), respectively. The plans in the supine and prone positions were designed using the xsight spine tracking (XST) and xsight spine prone tracking (XSPT) modalities, respectively. The dose-volume histogram (DVH) parameters, namely, V(100%), D(95%), D(mean), conformity index (CI), and heterogeneity index (HI) in planning target volume (PTV), as well as D(max), D(0.1cc), D(1cc), and D(5cc) in the cauda equina and bowel were recorded. The supine plans were simulation plans and were not used for treatment, which were only used to record the alignment errors. The spinal tracking correction errors (alignment error) and correlation errors of the synchrony respiratory model in the prone position were recorded during the treatment. After treatment, the simulation plan of the supine position was implemented and the spinal tracking correction errors were recorded. The parameters of correction error and DVH parameters for the two positions were analyzed using the paired t-test to compare the difference in positioning accuracy and dose distribution. In addition, the correlation errors of the synchrony respiratory model in the prone position were analyzed to evaluate the prediction accuracy of the synchrony model. RESULTS: For patient setup, the correction error of the supine position in interior/posterior was (0.18 ± 0.16) mm and the prone position was (0.31 ± 0.26) mm (P< 0.05). The correction error of the supine position in inferior/superior was (0.27 ± 0.24) mm, and the prone position was (0.5 ± 0.4) mm (P< 0.05). The average correlation errors of the synchrony model for left/right, inferior/superior, and anterior/posterior in the prone position were (0.21 ± 0.11) mm, (0.41 ± 0.38) mm, and (0.68 ± 0.42) mm, respectively. For the dose distribution, compared with prone plans, the average CI in supine plans was increased by 4.5% (P< 0.05). There was no significant difference in HI, PTV V(100%,) D(95%), and D(mean) between the prone and supine plans. Compared with supine plans, average D(1cc) and D(5cc) for the cauda equina was significantly decreased by 4.7 and 15.3% in the prone plan (P< 0.05). For the bowel, average D(max), D(0.1cc), D(1cc), and D(5cc) were reduced by 8.0, 7.7, 5.2, and 26.6% in prone plans (P< 0.05) compared with supine plans. CONCLUSION: Compared with the supine setup, the prone setup combined with XSPT modality for the lumbosacral spinal stereotactic body radiosurgery can spare the bowel and cauda equina of the middle and low dose irradiation, and decrease the number of beams and monitor units.
format Online
Article
Text
id pubmed-10106579
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-101065792023-04-18 Comparison between supine and prone patient setup for lumbosacral spinal stereotactic body radiosurgery with CyberKnife Li, Jun Kong, Xianghui cheng, Cheng Wang, Gong Zhuang, Hongqing Yang, Ruijie Front Oncol Oncology OBJECTIVE: The aim of this study is to analyze which tracking modality is more suitable for stereotactic body radiosurgery of lumbosacral spinal tumors by comparing prone and supine patient treatment setup. METHODS: Eighteen patients with lumbosacral spinal tumors were selected. CT simulation was performed in the supine position (fixed with a vacuum cushion) and prone position (fixed with a thermoplastic mask and prone plate), respectively. The plans in the supine and prone positions were designed using the xsight spine tracking (XST) and xsight spine prone tracking (XSPT) modalities, respectively. The dose-volume histogram (DVH) parameters, namely, V(100%), D(95%), D(mean), conformity index (CI), and heterogeneity index (HI) in planning target volume (PTV), as well as D(max), D(0.1cc), D(1cc), and D(5cc) in the cauda equina and bowel were recorded. The supine plans were simulation plans and were not used for treatment, which were only used to record the alignment errors. The spinal tracking correction errors (alignment error) and correlation errors of the synchrony respiratory model in the prone position were recorded during the treatment. After treatment, the simulation plan of the supine position was implemented and the spinal tracking correction errors were recorded. The parameters of correction error and DVH parameters for the two positions were analyzed using the paired t-test to compare the difference in positioning accuracy and dose distribution. In addition, the correlation errors of the synchrony respiratory model in the prone position were analyzed to evaluate the prediction accuracy of the synchrony model. RESULTS: For patient setup, the correction error of the supine position in interior/posterior was (0.18 ± 0.16) mm and the prone position was (0.31 ± 0.26) mm (P< 0.05). The correction error of the supine position in inferior/superior was (0.27 ± 0.24) mm, and the prone position was (0.5 ± 0.4) mm (P< 0.05). The average correlation errors of the synchrony model for left/right, inferior/superior, and anterior/posterior in the prone position were (0.21 ± 0.11) mm, (0.41 ± 0.38) mm, and (0.68 ± 0.42) mm, respectively. For the dose distribution, compared with prone plans, the average CI in supine plans was increased by 4.5% (P< 0.05). There was no significant difference in HI, PTV V(100%,) D(95%), and D(mean) between the prone and supine plans. Compared with supine plans, average D(1cc) and D(5cc) for the cauda equina was significantly decreased by 4.7 and 15.3% in the prone plan (P< 0.05). For the bowel, average D(max), D(0.1cc), D(1cc), and D(5cc) were reduced by 8.0, 7.7, 5.2, and 26.6% in prone plans (P< 0.05) compared with supine plans. CONCLUSION: Compared with the supine setup, the prone setup combined with XSPT modality for the lumbosacral spinal stereotactic body radiosurgery can spare the bowel and cauda equina of the middle and low dose irradiation, and decrease the number of beams and monitor units. Frontiers Media S.A. 2023-04-03 /pmc/articles/PMC10106579/ /pubmed/37077832 http://dx.doi.org/10.3389/fonc.2023.959447 Text en Copyright © 2023 Li, Kong, cheng, Wang, Zhuang and Yang https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Li, Jun
Kong, Xianghui
cheng, Cheng
Wang, Gong
Zhuang, Hongqing
Yang, Ruijie
Comparison between supine and prone patient setup for lumbosacral spinal stereotactic body radiosurgery with CyberKnife
title Comparison between supine and prone patient setup for lumbosacral spinal stereotactic body radiosurgery with CyberKnife
title_full Comparison between supine and prone patient setup for lumbosacral spinal stereotactic body radiosurgery with CyberKnife
title_fullStr Comparison between supine and prone patient setup for lumbosacral spinal stereotactic body radiosurgery with CyberKnife
title_full_unstemmed Comparison between supine and prone patient setup for lumbosacral spinal stereotactic body radiosurgery with CyberKnife
title_short Comparison between supine and prone patient setup for lumbosacral spinal stereotactic body radiosurgery with CyberKnife
title_sort comparison between supine and prone patient setup for lumbosacral spinal stereotactic body radiosurgery with cyberknife
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10106579/
https://www.ncbi.nlm.nih.gov/pubmed/37077832
http://dx.doi.org/10.3389/fonc.2023.959447
work_keys_str_mv AT lijun comparisonbetweensupineandpronepatientsetupforlumbosacralspinalstereotacticbodyradiosurgerywithcyberknife
AT kongxianghui comparisonbetweensupineandpronepatientsetupforlumbosacralspinalstereotacticbodyradiosurgerywithcyberknife
AT chengcheng comparisonbetweensupineandpronepatientsetupforlumbosacralspinalstereotacticbodyradiosurgerywithcyberknife
AT wanggong comparisonbetweensupineandpronepatientsetupforlumbosacralspinalstereotacticbodyradiosurgerywithcyberknife
AT zhuanghongqing comparisonbetweensupineandpronepatientsetupforlumbosacralspinalstereotacticbodyradiosurgerywithcyberknife
AT yangruijie comparisonbetweensupineandpronepatientsetupforlumbosacralspinalstereotacticbodyradiosurgerywithcyberknife