Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle

BACKGROUND: Left bundle branch pacemakers (LBBPs) can better maintain ventricular electrical synchronization than traditional right ventricular pacing (RVP). Temporary cardiac pacing (TCP) is needed to ensure the safety of the operation in patients undergoing LBBP. Currently, there are two methods o...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Zhenwei, Xu, Qingqing, Huangfu, Ning, Sun, Zewei, Su, Jia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10106659/
https://www.ncbi.nlm.nih.gov/pubmed/36798033
http://dx.doi.org/10.1002/clc.23992
_version_ 1785026452103626752
author Li, Zhenwei
Xu, Qingqing
Huangfu, Ning
Sun, Zewei
Su, Jia
author_facet Li, Zhenwei
Xu, Qingqing
Huangfu, Ning
Sun, Zewei
Su, Jia
author_sort Li, Zhenwei
collection PubMed
description BACKGROUND: Left bundle branch pacemakers (LBBPs) can better maintain ventricular electrical synchronization than traditional right ventricular pacing (RVP). Temporary cardiac pacing (TCP) is needed to ensure the safety of the operation in patients undergoing LBBP. Currently, there are two methods of installing TCP in conventional permanent pacemaker implantation. Hypothesis: To evaluate the safety and efficiency of replacing femoral vein pacing with atrial spiral pacing in the right ventricle for temporary cardiac pacing (TCP) during left bundle branch pacemaker (LBBP) implantation. METHOD: A total of 179 patients who underwent TCP during LBBP were selected for retrospective analysis from April 2019 to 2021 and divided into two groups: the atrial spiral electrode group (n = 76) and the femoral vein electrode group (n = 103). The following were observed: operation time; radiation dose; radiation time; operation expenses; hospitalization time; pacemaker parameters immediately after the operation and at 1 week, 1 month, 3 months, and 6 months after the operation; operation complications and femoral vein puncture point complications were observed in the two groups. RESULTS: Compared to the femoral vein electrode group, the atrial electrode group had significantly lower operation times ([116.86 ± 24.63] versus [128.94 ± 25.27] min, p < 0.05), radiation doses ([805.07 ± 132.94] versus [846.42 ± 87.37] mgy, p < 0.05), and decreased risk of a displaced or dislodged temporary pacing electrode during the operation ([0.00%] versus [4.85%], p < 0.05). The atrial electrode group did not have significant operation costs or material costs associated with femoral vein temporary pacing electrode implantation. In addition, the atrial electrode group did not have an increased risk of pacemaker‐related infections, and the parameters of the pacemaker were unaffected. However, some puncture point complications appeared in the femoral vein electrode group (8 cases of local subcutaneous hematoma, 3 cases of pseudoaneurysms, 3 cases of arteriovenous fistula). CONCLUSION: The replacement of the femoral vein pacing electrode with an atrial spiral pacing electrode in the right ventricle for TCP during LBBP implantation was safe and effective.
format Online
Article
Text
id pubmed-10106659
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-101066592023-04-18 Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle Li, Zhenwei Xu, Qingqing Huangfu, Ning Sun, Zewei Su, Jia Clin Cardiol Clinical Trial BACKGROUND: Left bundle branch pacemakers (LBBPs) can better maintain ventricular electrical synchronization than traditional right ventricular pacing (RVP). Temporary cardiac pacing (TCP) is needed to ensure the safety of the operation in patients undergoing LBBP. Currently, there are two methods of installing TCP in conventional permanent pacemaker implantation. Hypothesis: To evaluate the safety and efficiency of replacing femoral vein pacing with atrial spiral pacing in the right ventricle for temporary cardiac pacing (TCP) during left bundle branch pacemaker (LBBP) implantation. METHOD: A total of 179 patients who underwent TCP during LBBP were selected for retrospective analysis from April 2019 to 2021 and divided into two groups: the atrial spiral electrode group (n = 76) and the femoral vein electrode group (n = 103). The following were observed: operation time; radiation dose; radiation time; operation expenses; hospitalization time; pacemaker parameters immediately after the operation and at 1 week, 1 month, 3 months, and 6 months after the operation; operation complications and femoral vein puncture point complications were observed in the two groups. RESULTS: Compared to the femoral vein electrode group, the atrial electrode group had significantly lower operation times ([116.86 ± 24.63] versus [128.94 ± 25.27] min, p < 0.05), radiation doses ([805.07 ± 132.94] versus [846.42 ± 87.37] mgy, p < 0.05), and decreased risk of a displaced or dislodged temporary pacing electrode during the operation ([0.00%] versus [4.85%], p < 0.05). The atrial electrode group did not have significant operation costs or material costs associated with femoral vein temporary pacing electrode implantation. In addition, the atrial electrode group did not have an increased risk of pacemaker‐related infections, and the parameters of the pacemaker were unaffected. However, some puncture point complications appeared in the femoral vein electrode group (8 cases of local subcutaneous hematoma, 3 cases of pseudoaneurysms, 3 cases of arteriovenous fistula). CONCLUSION: The replacement of the femoral vein pacing electrode with an atrial spiral pacing electrode in the right ventricle for TCP during LBBP implantation was safe and effective. John Wiley and Sons Inc. 2023-02-16 /pmc/articles/PMC10106659/ /pubmed/36798033 http://dx.doi.org/10.1002/clc.23992 Text en © 2023 The Authors. Clinical Cardiology published by Wiley Periodicals, LLC. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Trial
Li, Zhenwei
Xu, Qingqing
Huangfu, Ning
Sun, Zewei
Su, Jia
Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle
title Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle
title_full Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle
title_fullStr Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle
title_full_unstemmed Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle
title_short Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle
title_sort comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle
topic Clinical Trial
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10106659/
https://www.ncbi.nlm.nih.gov/pubmed/36798033
http://dx.doi.org/10.1002/clc.23992
work_keys_str_mv AT lizhenwei comparisonofthesafetyandefficiencyoftemporarycardiacpacingmethodsduringleftbundlebranchpacemakerimplantationfemoralveinpacingversusatrialspiralpacingwithelectrodesplacedattheventricle
AT xuqingqing comparisonofthesafetyandefficiencyoftemporarycardiacpacingmethodsduringleftbundlebranchpacemakerimplantationfemoralveinpacingversusatrialspiralpacingwithelectrodesplacedattheventricle
AT huangfuning comparisonofthesafetyandefficiencyoftemporarycardiacpacingmethodsduringleftbundlebranchpacemakerimplantationfemoralveinpacingversusatrialspiralpacingwithelectrodesplacedattheventricle
AT sunzewei comparisonofthesafetyandefficiencyoftemporarycardiacpacingmethodsduringleftbundlebranchpacemakerimplantationfemoralveinpacingversusatrialspiralpacingwithelectrodesplacedattheventricle
AT sujia comparisonofthesafetyandefficiencyoftemporarycardiacpacingmethodsduringleftbundlebranchpacemakerimplantationfemoralveinpacingversusatrialspiralpacingwithelectrodesplacedattheventricle