Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle
BACKGROUND: Left bundle branch pacemakers (LBBPs) can better maintain ventricular electrical synchronization than traditional right ventricular pacing (RVP). Temporary cardiac pacing (TCP) is needed to ensure the safety of the operation in patients undergoing LBBP. Currently, there are two methods o...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10106659/ https://www.ncbi.nlm.nih.gov/pubmed/36798033 http://dx.doi.org/10.1002/clc.23992 |
_version_ | 1785026452103626752 |
---|---|
author | Li, Zhenwei Xu, Qingqing Huangfu, Ning Sun, Zewei Su, Jia |
author_facet | Li, Zhenwei Xu, Qingqing Huangfu, Ning Sun, Zewei Su, Jia |
author_sort | Li, Zhenwei |
collection | PubMed |
description | BACKGROUND: Left bundle branch pacemakers (LBBPs) can better maintain ventricular electrical synchronization than traditional right ventricular pacing (RVP). Temporary cardiac pacing (TCP) is needed to ensure the safety of the operation in patients undergoing LBBP. Currently, there are two methods of installing TCP in conventional permanent pacemaker implantation. Hypothesis: To evaluate the safety and efficiency of replacing femoral vein pacing with atrial spiral pacing in the right ventricle for temporary cardiac pacing (TCP) during left bundle branch pacemaker (LBBP) implantation. METHOD: A total of 179 patients who underwent TCP during LBBP were selected for retrospective analysis from April 2019 to 2021 and divided into two groups: the atrial spiral electrode group (n = 76) and the femoral vein electrode group (n = 103). The following were observed: operation time; radiation dose; radiation time; operation expenses; hospitalization time; pacemaker parameters immediately after the operation and at 1 week, 1 month, 3 months, and 6 months after the operation; operation complications and femoral vein puncture point complications were observed in the two groups. RESULTS: Compared to the femoral vein electrode group, the atrial electrode group had significantly lower operation times ([116.86 ± 24.63] versus [128.94 ± 25.27] min, p < 0.05), radiation doses ([805.07 ± 132.94] versus [846.42 ± 87.37] mgy, p < 0.05), and decreased risk of a displaced or dislodged temporary pacing electrode during the operation ([0.00%] versus [4.85%], p < 0.05). The atrial electrode group did not have significant operation costs or material costs associated with femoral vein temporary pacing electrode implantation. In addition, the atrial electrode group did not have an increased risk of pacemaker‐related infections, and the parameters of the pacemaker were unaffected. However, some puncture point complications appeared in the femoral vein electrode group (8 cases of local subcutaneous hematoma, 3 cases of pseudoaneurysms, 3 cases of arteriovenous fistula). CONCLUSION: The replacement of the femoral vein pacing electrode with an atrial spiral pacing electrode in the right ventricle for TCP during LBBP implantation was safe and effective. |
format | Online Article Text |
id | pubmed-10106659 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-101066592023-04-18 Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle Li, Zhenwei Xu, Qingqing Huangfu, Ning Sun, Zewei Su, Jia Clin Cardiol Clinical Trial BACKGROUND: Left bundle branch pacemakers (LBBPs) can better maintain ventricular electrical synchronization than traditional right ventricular pacing (RVP). Temporary cardiac pacing (TCP) is needed to ensure the safety of the operation in patients undergoing LBBP. Currently, there are two methods of installing TCP in conventional permanent pacemaker implantation. Hypothesis: To evaluate the safety and efficiency of replacing femoral vein pacing with atrial spiral pacing in the right ventricle for temporary cardiac pacing (TCP) during left bundle branch pacemaker (LBBP) implantation. METHOD: A total of 179 patients who underwent TCP during LBBP were selected for retrospective analysis from April 2019 to 2021 and divided into two groups: the atrial spiral electrode group (n = 76) and the femoral vein electrode group (n = 103). The following were observed: operation time; radiation dose; radiation time; operation expenses; hospitalization time; pacemaker parameters immediately after the operation and at 1 week, 1 month, 3 months, and 6 months after the operation; operation complications and femoral vein puncture point complications were observed in the two groups. RESULTS: Compared to the femoral vein electrode group, the atrial electrode group had significantly lower operation times ([116.86 ± 24.63] versus [128.94 ± 25.27] min, p < 0.05), radiation doses ([805.07 ± 132.94] versus [846.42 ± 87.37] mgy, p < 0.05), and decreased risk of a displaced or dislodged temporary pacing electrode during the operation ([0.00%] versus [4.85%], p < 0.05). The atrial electrode group did not have significant operation costs or material costs associated with femoral vein temporary pacing electrode implantation. In addition, the atrial electrode group did not have an increased risk of pacemaker‐related infections, and the parameters of the pacemaker were unaffected. However, some puncture point complications appeared in the femoral vein electrode group (8 cases of local subcutaneous hematoma, 3 cases of pseudoaneurysms, 3 cases of arteriovenous fistula). CONCLUSION: The replacement of the femoral vein pacing electrode with an atrial spiral pacing electrode in the right ventricle for TCP during LBBP implantation was safe and effective. John Wiley and Sons Inc. 2023-02-16 /pmc/articles/PMC10106659/ /pubmed/36798033 http://dx.doi.org/10.1002/clc.23992 Text en © 2023 The Authors. Clinical Cardiology published by Wiley Periodicals, LLC. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Trial Li, Zhenwei Xu, Qingqing Huangfu, Ning Sun, Zewei Su, Jia Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle |
title | Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle |
title_full | Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle |
title_fullStr | Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle |
title_full_unstemmed | Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle |
title_short | Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle |
title_sort | comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle |
topic | Clinical Trial |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10106659/ https://www.ncbi.nlm.nih.gov/pubmed/36798033 http://dx.doi.org/10.1002/clc.23992 |
work_keys_str_mv | AT lizhenwei comparisonofthesafetyandefficiencyoftemporarycardiacpacingmethodsduringleftbundlebranchpacemakerimplantationfemoralveinpacingversusatrialspiralpacingwithelectrodesplacedattheventricle AT xuqingqing comparisonofthesafetyandefficiencyoftemporarycardiacpacingmethodsduringleftbundlebranchpacemakerimplantationfemoralveinpacingversusatrialspiralpacingwithelectrodesplacedattheventricle AT huangfuning comparisonofthesafetyandefficiencyoftemporarycardiacpacingmethodsduringleftbundlebranchpacemakerimplantationfemoralveinpacingversusatrialspiralpacingwithelectrodesplacedattheventricle AT sunzewei comparisonofthesafetyandefficiencyoftemporarycardiacpacingmethodsduringleftbundlebranchpacemakerimplantationfemoralveinpacingversusatrialspiralpacingwithelectrodesplacedattheventricle AT sujia comparisonofthesafetyandefficiencyoftemporarycardiacpacingmethodsduringleftbundlebranchpacemakerimplantationfemoralveinpacingversusatrialspiralpacingwithelectrodesplacedattheventricle |