Cargando…

Comparison of biopolymer scaffolds for the fabrication of skin substitutes in a porcine wound model

This study compared three acellular scaffolds as templates for the fabrication of skin substitutes. A collagen‐glycosaminoglycan (C‐GAG), a biodegradable polyurethane foam (PUR) and a hybrid combination (PUR/C‐GAG) were investigated. Scaffolds were prepared for cell inoculation. Fibroblasts and kera...

Descripción completa

Detalles Bibliográficos
Autores principales: Dearman, Bronwyn L., Boyce, Steven T., Greenwood, John E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10107251/
https://www.ncbi.nlm.nih.gov/pubmed/36459148
http://dx.doi.org/10.1111/wrr.13059
_version_ 1785026565548015616
author Dearman, Bronwyn L.
Boyce, Steven T.
Greenwood, John E.
author_facet Dearman, Bronwyn L.
Boyce, Steven T.
Greenwood, John E.
author_sort Dearman, Bronwyn L.
collection PubMed
description This study compared three acellular scaffolds as templates for the fabrication of skin substitutes. A collagen‐glycosaminoglycan (C‐GAG), a biodegradable polyurethane foam (PUR) and a hybrid combination (PUR/C‐GAG) were investigated. Scaffolds were prepared for cell inoculation. Fibroblasts and keratinocytes were serially inoculated onto the scaffolds and co‐cultured for 14 days before transplantation. Three pigs each received four full‐thickness 8 cm × 8 cm surgical wounds, into which a biodegradable temporising matrix (BTM) was implanted. Surface seals were removed after integration (28 days), and three laboratory‐generated skin analogues and a control split‐thickness skin graft (STSG) were applied for 16 weeks. Punch biopsies confirmed engraftment and re‐epithelialisation. Biophysical wound parameters were also measured and analysed. All wounds showed greater than 80% epithelialisation by day 14 post‐transplantation. The control STSG displayed 44% contraction over the 16 weeks, and the test scaffolds, C‐GAG 64%, Hybrid 66.7% and PUR 67.8%. Immunohistochemistry confirmed positive epidermal keratins and basement membrane components (Integrin alpha‐6, collagens IV and VII). Collagen deposition and fibre organisation indicated the degree of fibrosis and scar produced for each graft. All scaffold substitutes re‐epithelialised by 4 weeks. The percentage of original wound area for the Hybrid and PUR was significantly different than the STSG and C‐GAG, indicating the importance of scaffold retainment within the first 3 months post‐transplant. The PUR/C‐GAG scaffolds reduced the polymer pore size, assisting cell retention and reducing the contraction of in vitro collagen. Further investigation is required to ensure reproducibility and scale‐up feasibility.
format Online
Article
Text
id pubmed-10107251
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-101072512023-04-18 Comparison of biopolymer scaffolds for the fabrication of skin substitutes in a porcine wound model Dearman, Bronwyn L. Boyce, Steven T. Greenwood, John E. Wound Repair Regen Original Article ‐ Basic Science This study compared three acellular scaffolds as templates for the fabrication of skin substitutes. A collagen‐glycosaminoglycan (C‐GAG), a biodegradable polyurethane foam (PUR) and a hybrid combination (PUR/C‐GAG) were investigated. Scaffolds were prepared for cell inoculation. Fibroblasts and keratinocytes were serially inoculated onto the scaffolds and co‐cultured for 14 days before transplantation. Three pigs each received four full‐thickness 8 cm × 8 cm surgical wounds, into which a biodegradable temporising matrix (BTM) was implanted. Surface seals were removed after integration (28 days), and three laboratory‐generated skin analogues and a control split‐thickness skin graft (STSG) were applied for 16 weeks. Punch biopsies confirmed engraftment and re‐epithelialisation. Biophysical wound parameters were also measured and analysed. All wounds showed greater than 80% epithelialisation by day 14 post‐transplantation. The control STSG displayed 44% contraction over the 16 weeks, and the test scaffolds, C‐GAG 64%, Hybrid 66.7% and PUR 67.8%. Immunohistochemistry confirmed positive epidermal keratins and basement membrane components (Integrin alpha‐6, collagens IV and VII). Collagen deposition and fibre organisation indicated the degree of fibrosis and scar produced for each graft. All scaffold substitutes re‐epithelialised by 4 weeks. The percentage of original wound area for the Hybrid and PUR was significantly different than the STSG and C‐GAG, indicating the importance of scaffold retainment within the first 3 months post‐transplant. The PUR/C‐GAG scaffolds reduced the polymer pore size, assisting cell retention and reducing the contraction of in vitro collagen. Further investigation is required to ensure reproducibility and scale‐up feasibility. John Wiley & Sons, Inc. 2022-12-12 2023 /pmc/articles/PMC10107251/ /pubmed/36459148 http://dx.doi.org/10.1111/wrr.13059 Text en © 2022 The Authors. Wound Repair and Regeneration published by Wiley Periodicals LLC on behalf of The Wound Healing Society. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Article ‐ Basic Science
Dearman, Bronwyn L.
Boyce, Steven T.
Greenwood, John E.
Comparison of biopolymer scaffolds for the fabrication of skin substitutes in a porcine wound model
title Comparison of biopolymer scaffolds for the fabrication of skin substitutes in a porcine wound model
title_full Comparison of biopolymer scaffolds for the fabrication of skin substitutes in a porcine wound model
title_fullStr Comparison of biopolymer scaffolds for the fabrication of skin substitutes in a porcine wound model
title_full_unstemmed Comparison of biopolymer scaffolds for the fabrication of skin substitutes in a porcine wound model
title_short Comparison of biopolymer scaffolds for the fabrication of skin substitutes in a porcine wound model
title_sort comparison of biopolymer scaffolds for the fabrication of skin substitutes in a porcine wound model
topic Original Article ‐ Basic Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10107251/
https://www.ncbi.nlm.nih.gov/pubmed/36459148
http://dx.doi.org/10.1111/wrr.13059
work_keys_str_mv AT dearmanbronwynl comparisonofbiopolymerscaffoldsforthefabricationofskinsubstitutesinaporcinewoundmodel
AT boycestevent comparisonofbiopolymerscaffoldsforthefabricationofskinsubstitutesinaporcinewoundmodel
AT greenwoodjohne comparisonofbiopolymerscaffoldsforthefabricationofskinsubstitutesinaporcinewoundmodel