Cargando…

Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population

BACKGROUND: To compare the clinical outcomes of bilateral implantation of enhanced intermediate function intraocular lenses (IOLs) and standard monofocal IOLs. METHODS: In this prospective, randomized, comparative controlled study, we compared the visual outcomes of patients who underwent bilateral...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Wan Kyu, Han, Hyo Ji, Son, Hyeck-Soo, Khoramnia, Ramin, Auffarth, Gerd U., Choi, Chul Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10108453/
https://www.ncbi.nlm.nih.gov/pubmed/37069559
http://dx.doi.org/10.1186/s12886-023-02897-2
_version_ 1785026851464282112
author Choi, Wan Kyu
Han, Hyo Ji
Son, Hyeck-Soo
Khoramnia, Ramin
Auffarth, Gerd U.
Choi, Chul Young
author_facet Choi, Wan Kyu
Han, Hyo Ji
Son, Hyeck-Soo
Khoramnia, Ramin
Auffarth, Gerd U.
Choi, Chul Young
author_sort Choi, Wan Kyu
collection PubMed
description BACKGROUND: To compare the clinical outcomes of bilateral implantation of enhanced intermediate function intraocular lenses (IOLs) and standard monofocal IOLs. METHODS: In this prospective, randomized, comparative controlled study, we compared the visual outcomes of patients who underwent bilateral cataract surgery at the Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, with either enhanced monofocal IOLs (Tecnis Eyhance, ICB00, Johnson and Johnson Vision Care, Inc) (Group 1) or standard monofocal IOLs (Tecnis, ZCB00, Johnson and Johnson Vision Care, Inc) (Group 2). The assessment included monocular and binocular uncorrected distance visual acuity (UDVA), uncorrected intermediate (UIVA at 60 cm) and near (UNVA at 40 cm) visual acuity, uncorrected defocus curves, contrast sensitivity testing (CST), and reading speed test using Quality of vision was evaluated using the Visual Function Questionnaire (VFQ-25). RESULTS: At 3-months postoperatively, monocular and binocular outcomes of UIVA and UNVA were statistically significantly better in Group 1 (P < 0.05). The binocular uncorrected defocus curve of Group 1 showed statistically significantly better outcomes at vergence ranges of -1.5 to -4.0 D (P < 0.05). Significantly higher reading speed test was also observed in Group 1 in all ranges tested (1.0 to 0.1 LogMAR) (P < 0.05). There were no statistically significant differences in CST between groups. CONCLUSIONS: Bilateral implantation of enhanced monofocal IOLs provided better vision at intermediate and near distances compared to standard monofocal IOLs, while maintaining good distance vision and contrast sensitivity.
format Online
Article
Text
id pubmed-10108453
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-101084532023-04-18 Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population Choi, Wan Kyu Han, Hyo Ji Son, Hyeck-Soo Khoramnia, Ramin Auffarth, Gerd U. Choi, Chul Young BMC Ophthalmol Research BACKGROUND: To compare the clinical outcomes of bilateral implantation of enhanced intermediate function intraocular lenses (IOLs) and standard monofocal IOLs. METHODS: In this prospective, randomized, comparative controlled study, we compared the visual outcomes of patients who underwent bilateral cataract surgery at the Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, with either enhanced monofocal IOLs (Tecnis Eyhance, ICB00, Johnson and Johnson Vision Care, Inc) (Group 1) or standard monofocal IOLs (Tecnis, ZCB00, Johnson and Johnson Vision Care, Inc) (Group 2). The assessment included monocular and binocular uncorrected distance visual acuity (UDVA), uncorrected intermediate (UIVA at 60 cm) and near (UNVA at 40 cm) visual acuity, uncorrected defocus curves, contrast sensitivity testing (CST), and reading speed test using Quality of vision was evaluated using the Visual Function Questionnaire (VFQ-25). RESULTS: At 3-months postoperatively, monocular and binocular outcomes of UIVA and UNVA were statistically significantly better in Group 1 (P < 0.05). The binocular uncorrected defocus curve of Group 1 showed statistically significantly better outcomes at vergence ranges of -1.5 to -4.0 D (P < 0.05). Significantly higher reading speed test was also observed in Group 1 in all ranges tested (1.0 to 0.1 LogMAR) (P < 0.05). There were no statistically significant differences in CST between groups. CONCLUSIONS: Bilateral implantation of enhanced monofocal IOLs provided better vision at intermediate and near distances compared to standard monofocal IOLs, while maintaining good distance vision and contrast sensitivity. BioMed Central 2023-04-17 /pmc/articles/PMC10108453/ /pubmed/37069559 http://dx.doi.org/10.1186/s12886-023-02897-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Choi, Wan Kyu
Han, Hyo Ji
Son, Hyeck-Soo
Khoramnia, Ramin
Auffarth, Gerd U.
Choi, Chul Young
Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population
title Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population
title_full Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population
title_fullStr Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population
title_full_unstemmed Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population
title_short Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population
title_sort clinical outcomes of bilateral implantation of new generation monofocal iol enhanced for intermediate distance and conventional monofocal iol in a korean population
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10108453/
https://www.ncbi.nlm.nih.gov/pubmed/37069559
http://dx.doi.org/10.1186/s12886-023-02897-2
work_keys_str_mv AT choiwankyu clinicaloutcomesofbilateralimplantationofnewgenerationmonofocaliolenhancedforintermediatedistanceandconventionalmonofocaliolinakoreanpopulation
AT hanhyoji clinicaloutcomesofbilateralimplantationofnewgenerationmonofocaliolenhancedforintermediatedistanceandconventionalmonofocaliolinakoreanpopulation
AT sonhyecksoo clinicaloutcomesofbilateralimplantationofnewgenerationmonofocaliolenhancedforintermediatedistanceandconventionalmonofocaliolinakoreanpopulation
AT khoramniaramin clinicaloutcomesofbilateralimplantationofnewgenerationmonofocaliolenhancedforintermediatedistanceandconventionalmonofocaliolinakoreanpopulation
AT auffarthgerdu clinicaloutcomesofbilateralimplantationofnewgenerationmonofocaliolenhancedforintermediatedistanceandconventionalmonofocaliolinakoreanpopulation
AT choichulyoung clinicaloutcomesofbilateralimplantationofnewgenerationmonofocaliolenhancedforintermediatedistanceandconventionalmonofocaliolinakoreanpopulation