BACKGROUND: To compare the clinical outcomes of bilateral implantation of enhanced intermediate function intraocular lenses (IOLs) and standard monofocal IOLs. METHODS: In this prospective, randomized, comparative controlled study, we compared the visual outcomes of patients who underwent bilateral...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10108453/ https://www.ncbi.nlm.nih.gov/pubmed/37069559 http://dx.doi.org/10.1186/s12886-023-02897-2 |
_version_ | 1785026851464282112 |
---|---|
author | Choi, Wan Kyu Han, Hyo Ji Son, Hyeck-Soo Khoramnia, Ramin Auffarth, Gerd U. Choi, Chul Young |
author_facet | Choi, Wan Kyu Han, Hyo Ji Son, Hyeck-Soo Khoramnia, Ramin Auffarth, Gerd U. Choi, Chul Young |
author_sort | Choi, Wan Kyu |
collection | PubMed |
description | BACKGROUND: To compare the clinical outcomes of bilateral implantation of enhanced intermediate function intraocular lenses (IOLs) and standard monofocal IOLs. METHODS: In this prospective, randomized, comparative controlled study, we compared the visual outcomes of patients who underwent bilateral cataract surgery at the Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, with either enhanced monofocal IOLs (Tecnis Eyhance, ICB00, Johnson and Johnson Vision Care, Inc) (Group 1) or standard monofocal IOLs (Tecnis, ZCB00, Johnson and Johnson Vision Care, Inc) (Group 2). The assessment included monocular and binocular uncorrected distance visual acuity (UDVA), uncorrected intermediate (UIVA at 60 cm) and near (UNVA at 40 cm) visual acuity, uncorrected defocus curves, contrast sensitivity testing (CST), and reading speed test using Quality of vision was evaluated using the Visual Function Questionnaire (VFQ-25). RESULTS: At 3-months postoperatively, monocular and binocular outcomes of UIVA and UNVA were statistically significantly better in Group 1 (P < 0.05). The binocular uncorrected defocus curve of Group 1 showed statistically significantly better outcomes at vergence ranges of -1.5 to -4.0 D (P < 0.05). Significantly higher reading speed test was also observed in Group 1 in all ranges tested (1.0 to 0.1 LogMAR) (P < 0.05). There were no statistically significant differences in CST between groups. CONCLUSIONS: Bilateral implantation of enhanced monofocal IOLs provided better vision at intermediate and near distances compared to standard monofocal IOLs, while maintaining good distance vision and contrast sensitivity. |
format | Online Article Text |
id | pubmed-10108453 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-101084532023-04-18 Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population Choi, Wan Kyu Han, Hyo Ji Son, Hyeck-Soo Khoramnia, Ramin Auffarth, Gerd U. Choi, Chul Young BMC Ophthalmol Research BACKGROUND: To compare the clinical outcomes of bilateral implantation of enhanced intermediate function intraocular lenses (IOLs) and standard monofocal IOLs. METHODS: In this prospective, randomized, comparative controlled study, we compared the visual outcomes of patients who underwent bilateral cataract surgery at the Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, with either enhanced monofocal IOLs (Tecnis Eyhance, ICB00, Johnson and Johnson Vision Care, Inc) (Group 1) or standard monofocal IOLs (Tecnis, ZCB00, Johnson and Johnson Vision Care, Inc) (Group 2). The assessment included monocular and binocular uncorrected distance visual acuity (UDVA), uncorrected intermediate (UIVA at 60 cm) and near (UNVA at 40 cm) visual acuity, uncorrected defocus curves, contrast sensitivity testing (CST), and reading speed test using Quality of vision was evaluated using the Visual Function Questionnaire (VFQ-25). RESULTS: At 3-months postoperatively, monocular and binocular outcomes of UIVA and UNVA were statistically significantly better in Group 1 (P < 0.05). The binocular uncorrected defocus curve of Group 1 showed statistically significantly better outcomes at vergence ranges of -1.5 to -4.0 D (P < 0.05). Significantly higher reading speed test was also observed in Group 1 in all ranges tested (1.0 to 0.1 LogMAR) (P < 0.05). There were no statistically significant differences in CST between groups. CONCLUSIONS: Bilateral implantation of enhanced monofocal IOLs provided better vision at intermediate and near distances compared to standard monofocal IOLs, while maintaining good distance vision and contrast sensitivity. BioMed Central 2023-04-17 /pmc/articles/PMC10108453/ /pubmed/37069559 http://dx.doi.org/10.1186/s12886-023-02897-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Choi, Wan Kyu Han, Hyo Ji Son, Hyeck-Soo Khoramnia, Ramin Auffarth, Gerd U. Choi, Chul Young Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population |
title | Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population |
title_full | Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population |
title_fullStr | Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population |
title_full_unstemmed | Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population |
title_short | Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population |
title_sort | clinical outcomes of bilateral implantation of new generation monofocal iol enhanced for intermediate distance and conventional monofocal iol in a korean population |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10108453/ https://www.ncbi.nlm.nih.gov/pubmed/37069559 http://dx.doi.org/10.1186/s12886-023-02897-2 |
work_keys_str_mv | AT choiwankyu clinicaloutcomesofbilateralimplantationofnewgenerationmonofocaliolenhancedforintermediatedistanceandconventionalmonofocaliolinakoreanpopulation AT hanhyoji clinicaloutcomesofbilateralimplantationofnewgenerationmonofocaliolenhancedforintermediatedistanceandconventionalmonofocaliolinakoreanpopulation AT sonhyecksoo clinicaloutcomesofbilateralimplantationofnewgenerationmonofocaliolenhancedforintermediatedistanceandconventionalmonofocaliolinakoreanpopulation AT khoramniaramin clinicaloutcomesofbilateralimplantationofnewgenerationmonofocaliolenhancedforintermediatedistanceandconventionalmonofocaliolinakoreanpopulation AT auffarthgerdu clinicaloutcomesofbilateralimplantationofnewgenerationmonofocaliolenhancedforintermediatedistanceandconventionalmonofocaliolinakoreanpopulation AT choichulyoung clinicaloutcomesofbilateralimplantationofnewgenerationmonofocaliolenhancedforintermediatedistanceandconventionalmonofocaliolinakoreanpopulation |