Cargando…
Knee kinematics during staircase descent: native, after bi-cruciate retaining and bi-cruciate stabilized total knee arthroplasty
AIMS: The goal was to evaluate tibiofemoral knee joint kinematics during stair descent, by simulating the full stair descent motion in vitro. The knee joint kinematics were evaluated for two types of knee implants: bi-cruciate retaining and bi-cruciate stabilized. It was hypothesized that the bi-cru...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The British Editorial Society of Bone & Joint Surgery
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10108725/ https://www.ncbi.nlm.nih.gov/pubmed/37067369 http://dx.doi.org/10.1302/2046-3758.124.BJR-2022-0298.R2 |
_version_ | 1785026899940999168 |
---|---|
author | Chevalier, Amelie Vermue, Hannes Pringels, Lauren Herregodts, Stijn Duquesne, Kate Victor, Jan Loccufier, Mia |
author_facet | Chevalier, Amelie Vermue, Hannes Pringels, Lauren Herregodts, Stijn Duquesne, Kate Victor, Jan Loccufier, Mia |
author_sort | Chevalier, Amelie |
collection | PubMed |
description | AIMS: The goal was to evaluate tibiofemoral knee joint kinematics during stair descent, by simulating the full stair descent motion in vitro. The knee joint kinematics were evaluated for two types of knee implants: bi-cruciate retaining and bi-cruciate stabilized. It was hypothesized that the bi-cruciate retaining implant better approximates native kinematics. METHODS: The in vitro study included 20 specimens which were tested during a full stair descent with physiological muscle forces in a dynamic knee rig. Laxity envelopes were measured by applying external loading conditions in varus/valgus and internal/external direction. RESULTS: The laxity results show that both implants are capable of mimicking the native internal/external-laxity during the controlled lowering phase. The kinematic results show that the bi-cruciate retaining implant tends to approximate the native condition better compared to bi-cruciate stabilized implant. This is valid for the internal/external rotation and the anteroposterior translation during all phases of the stair descent, and for the compression-distraction of the knee joint during swing and controlled lowering phase. CONCLUSION: The results show a better approximation of the native kinematics by the bi-cruciate retaining knee implant compared to the bi-cruciate stabilized knee implant for internal/external rotation and anteroposterior translation. Whether this will result in better patient outcomes remains to be investigated. Cite this article: Bone Joint Res 2023;12(4):285–293. |
format | Online Article Text |
id | pubmed-10108725 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The British Editorial Society of Bone & Joint Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-101087252023-04-18 Knee kinematics during staircase descent: native, after bi-cruciate retaining and bi-cruciate stabilized total knee arthroplasty Chevalier, Amelie Vermue, Hannes Pringels, Lauren Herregodts, Stijn Duquesne, Kate Victor, Jan Loccufier, Mia Bone Joint Res Knee AIMS: The goal was to evaluate tibiofemoral knee joint kinematics during stair descent, by simulating the full stair descent motion in vitro. The knee joint kinematics were evaluated for two types of knee implants: bi-cruciate retaining and bi-cruciate stabilized. It was hypothesized that the bi-cruciate retaining implant better approximates native kinematics. METHODS: The in vitro study included 20 specimens which were tested during a full stair descent with physiological muscle forces in a dynamic knee rig. Laxity envelopes were measured by applying external loading conditions in varus/valgus and internal/external direction. RESULTS: The laxity results show that both implants are capable of mimicking the native internal/external-laxity during the controlled lowering phase. The kinematic results show that the bi-cruciate retaining implant tends to approximate the native condition better compared to bi-cruciate stabilized implant. This is valid for the internal/external rotation and the anteroposterior translation during all phases of the stair descent, and for the compression-distraction of the knee joint during swing and controlled lowering phase. CONCLUSION: The results show a better approximation of the native kinematics by the bi-cruciate retaining knee implant compared to the bi-cruciate stabilized knee implant for internal/external rotation and anteroposterior translation. Whether this will result in better patient outcomes remains to be investigated. Cite this article: Bone Joint Res 2023;12(4):285–293. The British Editorial Society of Bone & Joint Surgery 2023-04-17 /pmc/articles/PMC10108725/ /pubmed/37067369 http://dx.doi.org/10.1302/2046-3758.124.BJR-2022-0298.R2 Text en © 2023 Author(s) et al. https://creativecommons.org/licenses/by-nc-nd/4.0/https://online.boneandjoint.org.uk/TDMThis is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND 4.0) licence, which permits the copying and redistribution of the work only, and provided the original author and source are credited. See https://creativecommons.org/licenses/by-nc-nd/4.0/ |
spellingShingle | Knee Chevalier, Amelie Vermue, Hannes Pringels, Lauren Herregodts, Stijn Duquesne, Kate Victor, Jan Loccufier, Mia Knee kinematics during staircase descent: native, after bi-cruciate retaining and bi-cruciate stabilized total knee arthroplasty |
title | Knee kinematics during staircase descent: native, after bi-cruciate retaining and bi-cruciate stabilized total knee arthroplasty |
title_full | Knee kinematics during staircase descent: native, after bi-cruciate retaining and bi-cruciate stabilized total knee arthroplasty |
title_fullStr | Knee kinematics during staircase descent: native, after bi-cruciate retaining and bi-cruciate stabilized total knee arthroplasty |
title_full_unstemmed | Knee kinematics during staircase descent: native, after bi-cruciate retaining and bi-cruciate stabilized total knee arthroplasty |
title_short | Knee kinematics during staircase descent: native, after bi-cruciate retaining and bi-cruciate stabilized total knee arthroplasty |
title_sort | knee kinematics during staircase descent: native, after bi-cruciate retaining and bi-cruciate stabilized total knee arthroplasty |
topic | Knee |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10108725/ https://www.ncbi.nlm.nih.gov/pubmed/37067369 http://dx.doi.org/10.1302/2046-3758.124.BJR-2022-0298.R2 |
work_keys_str_mv | AT chevalieramelie kneekinematicsduringstaircasedescentnativeafterbicruciateretainingandbicruciatestabilizedtotalkneearthroplasty AT vermuehannes kneekinematicsduringstaircasedescentnativeafterbicruciateretainingandbicruciatestabilizedtotalkneearthroplasty AT pringelslauren kneekinematicsduringstaircasedescentnativeafterbicruciateretainingandbicruciatestabilizedtotalkneearthroplasty AT herregodtsstijn kneekinematicsduringstaircasedescentnativeafterbicruciateretainingandbicruciatestabilizedtotalkneearthroplasty AT duquesnekate kneekinematicsduringstaircasedescentnativeafterbicruciateretainingandbicruciatestabilizedtotalkneearthroplasty AT victorjan kneekinematicsduringstaircasedescentnativeafterbicruciateretainingandbicruciatestabilizedtotalkneearthroplasty AT loccufiermia kneekinematicsduringstaircasedescentnativeafterbicruciateretainingandbicruciatestabilizedtotalkneearthroplasty |