P145 Assessing the Performance of Automatic Analysis During Routine Intralab Conordance Activities

INTRODUCTION: This study aims to retrospectively assess the performance of somnolyzer against trained scientist performance of PSG analysis, under routine interlab concordance conditions in an Australian laboratory. METHODS: Retrospective study (2016 – 2018). Study data included 200 epoc fragments w...

Descripción completa

Detalles Bibliográficos
Autores principales: Teuwen, P, Eriksson, N, Mateus, E, Dalman, M, Yau, Y, Scott, A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10108919/
http://dx.doi.org/10.1093/sleepadvances/zpab014.186
_version_ 1785026942774280192
author Teuwen, P
Eriksson, N
Mateus, E
Dalman, M
Yau, Y
Scott, A
author_facet Teuwen, P
Eriksson, N
Mateus, E
Dalman, M
Yau, Y
Scott, A
author_sort Teuwen, P
collection PubMed
description INTRODUCTION: This study aims to retrospectively assess the performance of somnolyzer against trained scientist performance of PSG analysis, under routine interlab concordance conditions in an Australian laboratory. METHODS: Retrospective study (2016 – 2018). Study data included 200 epoc fragments with SWS, REM and NREM. PSG data sets (n = 36) consisted of type 1 (n = 31) and type 2 (n = 5) studies. Individual scorers were compared to a master scoreset set by consensus from two experienced sleep scientists. The automatic analysis system used was Somnolyzer 24x7. Data analysis involved; Group 1: intraclass correlations and Bland-Altman plots, Group 2: Paired T-tests. RESULTS: Human analysis was shown to outperform automatic analysis in each major metric assessed, except sleep latency. Automatic analysis performed to a similar level in 6 out of 9 of the major metrics assessed (r > 0.9), however the 95% limit of agreement range was found to larger. Automatically analysed RDI’s were more likely to be lower than the master score sets, as were arousal indices. CONCLUSIONS: These findings support using caution with automatic analysis, particularly with medical interpretation and practice. Automatic analysis performance can vary dramatically between PSG data sets. This output can vary from one that is comparable to a human analysis through to a level that is well below that of human scorers, under concordance conditions. Consideration should be given to the accuracy of automatic analysis when making scientific conclusions with borderline cases.
format Online
Article
Text
id pubmed-10108919
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-101089192023-05-15 P145 Assessing the Performance of Automatic Analysis During Routine Intralab Conordance Activities Teuwen, P Eriksson, N Mateus, E Dalman, M Yau, Y Scott, A Sleep Adv Poster Presentations INTRODUCTION: This study aims to retrospectively assess the performance of somnolyzer against trained scientist performance of PSG analysis, under routine interlab concordance conditions in an Australian laboratory. METHODS: Retrospective study (2016 – 2018). Study data included 200 epoc fragments with SWS, REM and NREM. PSG data sets (n = 36) consisted of type 1 (n = 31) and type 2 (n = 5) studies. Individual scorers were compared to a master scoreset set by consensus from two experienced sleep scientists. The automatic analysis system used was Somnolyzer 24x7. Data analysis involved; Group 1: intraclass correlations and Bland-Altman plots, Group 2: Paired T-tests. RESULTS: Human analysis was shown to outperform automatic analysis in each major metric assessed, except sleep latency. Automatic analysis performed to a similar level in 6 out of 9 of the major metrics assessed (r > 0.9), however the 95% limit of agreement range was found to larger. Automatically analysed RDI’s were more likely to be lower than the master score sets, as were arousal indices. CONCLUSIONS: These findings support using caution with automatic analysis, particularly with medical interpretation and practice. Automatic analysis performance can vary dramatically between PSG data sets. This output can vary from one that is comparable to a human analysis through to a level that is well below that of human scorers, under concordance conditions. Consideration should be given to the accuracy of automatic analysis when making scientific conclusions with borderline cases. Oxford University Press 2021-10-07 /pmc/articles/PMC10108919/ http://dx.doi.org/10.1093/sleepadvances/zpab014.186 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of Sleep Research Society. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Poster Presentations
Teuwen, P
Eriksson, N
Mateus, E
Dalman, M
Yau, Y
Scott, A
P145 Assessing the Performance of Automatic Analysis During Routine Intralab Conordance Activities
title P145 Assessing the Performance of Automatic Analysis During Routine Intralab Conordance Activities
title_full P145 Assessing the Performance of Automatic Analysis During Routine Intralab Conordance Activities
title_fullStr P145 Assessing the Performance of Automatic Analysis During Routine Intralab Conordance Activities
title_full_unstemmed P145 Assessing the Performance of Automatic Analysis During Routine Intralab Conordance Activities
title_short P145 Assessing the Performance of Automatic Analysis During Routine Intralab Conordance Activities
title_sort p145 assessing the performance of automatic analysis during routine intralab conordance activities
topic Poster Presentations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10108919/
http://dx.doi.org/10.1093/sleepadvances/zpab014.186
work_keys_str_mv AT teuwenp p145assessingtheperformanceofautomaticanalysisduringroutineintralabconordanceactivities
AT erikssonn p145assessingtheperformanceofautomaticanalysisduringroutineintralabconordanceactivities
AT mateuse p145assessingtheperformanceofautomaticanalysisduringroutineintralabconordanceactivities
AT dalmanm p145assessingtheperformanceofautomaticanalysisduringroutineintralabconordanceactivities
AT yauy p145assessingtheperformanceofautomaticanalysisduringroutineintralabconordanceactivities
AT scotta p145assessingtheperformanceofautomaticanalysisduringroutineintralabconordanceactivities