Cargando…
P023 Quantitative EEG analysis of polysomnography in a case of Fatal Familial Insomnia
PURPOSE: To report on quantitative electroencephalograph (EEG) activity during polysomnography (PSG) in a rare case of confirmed Fatal Familial Insomnia (FFI). METHODS: Sleep/wake characteristics of a 32-year-old male patient were quantitatively analysed using central EEG recordings during two PSGs...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10109051/ http://dx.doi.org/10.1093/sleepadvances/zpab014.071 |
_version_ | 1785026974587027456 |
---|---|
author | Churchward, T Kao, C D’Rozario, A Wimaleswaran, H McMahon, M Howard, M Tolson, J Ruehland, W |
author_facet | Churchward, T Kao, C D’Rozario, A Wimaleswaran, H McMahon, M Howard, M Tolson, J Ruehland, W |
author_sort | Churchward, T |
collection | PubMed |
description | PURPOSE: To report on quantitative electroencephalograph (EEG) activity during polysomnography (PSG) in a rare case of confirmed Fatal Familial Insomnia (FFI). METHODS: Sleep/wake characteristics of a 32-year-old male patient were quantitatively analysed using central EEG recordings during two PSGs (FFI-1 and FFI-2) first, for investigation of insomnia and PLMS but with no suspicion of FFI and second, 120 days later with suspected but unconfirmed FFI at the time; 89 days prior to death. PSG metrics; absolute EEG power in specified frequency bands; EEG slowing ratio of slow-to-fast frequencies ((delta + theta)/ (alpha + sigma + beta)); and sleep spindle density were calculated. Results were compared with gender and age-matched insomnia and healthy controls (two of each). RESULTS: FFI-1 and FFI-2 PSGs revealed total time in bed of 413.5 and 392 minutes, total sleep times of 208.5 and 7.5 minute, including NREM 153.0 and 2.5 minutes, and REM 55.5 and 5.0 minutes, respectively. FFI-1 had approximately 1.5 times lower slow wave activity (SWA, 0.5–4.5Hz) during N3 than insomnia and controls. FFI-1 had 2 times and 1.8 times higher slowing ratio during REM than insomnia and controls, respectively. Spindle density (per minute of NREM sleep) for FFI-1 was 0.9, compared to pair-averages of 1.2 for insomnia disorder and 4.7 for healthy controls. CONCLUSIONS: PSG in FFI revealed poor sleep efficiency that severely deteriorated with disease progression. Quantitative analysis of EEG revealed lower spindle density, lower SWA in N3, and higher slowing ratio in REM, when compared to insomnia patients and healthy sleepers. |
format | Online Article Text |
id | pubmed-10109051 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-101090512023-05-15 P023 Quantitative EEG analysis of polysomnography in a case of Fatal Familial Insomnia Churchward, T Kao, C D’Rozario, A Wimaleswaran, H McMahon, M Howard, M Tolson, J Ruehland, W Sleep Adv Poster Presentations PURPOSE: To report on quantitative electroencephalograph (EEG) activity during polysomnography (PSG) in a rare case of confirmed Fatal Familial Insomnia (FFI). METHODS: Sleep/wake characteristics of a 32-year-old male patient were quantitatively analysed using central EEG recordings during two PSGs (FFI-1 and FFI-2) first, for investigation of insomnia and PLMS but with no suspicion of FFI and second, 120 days later with suspected but unconfirmed FFI at the time; 89 days prior to death. PSG metrics; absolute EEG power in specified frequency bands; EEG slowing ratio of slow-to-fast frequencies ((delta + theta)/ (alpha + sigma + beta)); and sleep spindle density were calculated. Results were compared with gender and age-matched insomnia and healthy controls (two of each). RESULTS: FFI-1 and FFI-2 PSGs revealed total time in bed of 413.5 and 392 minutes, total sleep times of 208.5 and 7.5 minute, including NREM 153.0 and 2.5 minutes, and REM 55.5 and 5.0 minutes, respectively. FFI-1 had approximately 1.5 times lower slow wave activity (SWA, 0.5–4.5Hz) during N3 than insomnia and controls. FFI-1 had 2 times and 1.8 times higher slowing ratio during REM than insomnia and controls, respectively. Spindle density (per minute of NREM sleep) for FFI-1 was 0.9, compared to pair-averages of 1.2 for insomnia disorder and 4.7 for healthy controls. CONCLUSIONS: PSG in FFI revealed poor sleep efficiency that severely deteriorated with disease progression. Quantitative analysis of EEG revealed lower spindle density, lower SWA in N3, and higher slowing ratio in REM, when compared to insomnia patients and healthy sleepers. Oxford University Press 2021-10-07 /pmc/articles/PMC10109051/ http://dx.doi.org/10.1093/sleepadvances/zpab014.071 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of Sleep Research Society. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Poster Presentations Churchward, T Kao, C D’Rozario, A Wimaleswaran, H McMahon, M Howard, M Tolson, J Ruehland, W P023 Quantitative EEG analysis of polysomnography in a case of Fatal Familial Insomnia |
title | P023 Quantitative EEG analysis of polysomnography in a case of Fatal Familial Insomnia |
title_full | P023 Quantitative EEG analysis of polysomnography in a case of Fatal Familial Insomnia |
title_fullStr | P023 Quantitative EEG analysis of polysomnography in a case of Fatal Familial Insomnia |
title_full_unstemmed | P023 Quantitative EEG analysis of polysomnography in a case of Fatal Familial Insomnia |
title_short | P023 Quantitative EEG analysis of polysomnography in a case of Fatal Familial Insomnia |
title_sort | p023 quantitative eeg analysis of polysomnography in a case of fatal familial insomnia |
topic | Poster Presentations |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10109051/ http://dx.doi.org/10.1093/sleepadvances/zpab014.071 |
work_keys_str_mv | AT churchwardt p023quantitativeeeganalysisofpolysomnographyinacaseoffatalfamilialinsomnia AT kaoc p023quantitativeeeganalysisofpolysomnographyinacaseoffatalfamilialinsomnia AT drozarioa p023quantitativeeeganalysisofpolysomnographyinacaseoffatalfamilialinsomnia AT wimaleswaranh p023quantitativeeeganalysisofpolysomnographyinacaseoffatalfamilialinsomnia AT mcmahonm p023quantitativeeeganalysisofpolysomnographyinacaseoffatalfamilialinsomnia AT howardm p023quantitativeeeganalysisofpolysomnographyinacaseoffatalfamilialinsomnia AT tolsonj p023quantitativeeeganalysisofpolysomnographyinacaseoffatalfamilialinsomnia AT ruehlandw p023quantitativeeeganalysisofpolysomnographyinacaseoffatalfamilialinsomnia |