P123 Accuracy and Reliability of the Transcutaneous Carbon Dioxide (TcCO2) Signal in the Sleep Laboratory

Carbon Dioxide (CO2) monitoring is an essential part of assessing and treating disorders of hypoventilation in the sleep laboratory. While reliablity issues have been previously reported with the Transcutaneous Carbon Dioxide (TcCO2) signal, there is limited data assessing the validity of this signa...

Descripción completa

Detalles Bibliográficos
Autores principales: Rossely, A, Turton, A, Roebuck, T, Ho, S, Naughton, M, Mansfield, D, Hamilton, G
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10109359/
http://dx.doi.org/10.1093/sleepadvances/zpab014.164
_version_ 1785027048103739392
author Rossely, A
Turton, A
Roebuck, T
Ho, S
Naughton, M
Mansfield, D
Hamilton, G
author_facet Rossely, A
Turton, A
Roebuck, T
Ho, S
Naughton, M
Mansfield, D
Hamilton, G
author_sort Rossely, A
collection PubMed
description Carbon Dioxide (CO2) monitoring is an essential part of assessing and treating disorders of hypoventilation in the sleep laboratory. While reliablity issues have been previously reported with the Transcutaneous Carbon Dioxide (TcCO2) signal, there is limited data assessing the validity of this signal or its trend in the sleep laboratory context. Therefore, this study aimed to investigate the change in TcCO2 accuracy from the beginning to the end of the sleep study in real world conditions across two different Victorian public hospital sleep laboratories that used two different TcCO2 monitors. The sample included 13 consecutive patients from Monash Health and 44 consecutive patients from Alfred Health with an average age of 64 and 56 years respectively. Arterial Blood Gas (ABG) measurements were taken prior to and following each sleep study and compared concurrently with the TcCO2 value. Bland-Altman analysis revealed an average difference between TcCO2 and PaCO2 of 3.29mmHg with agreement between -11.44 and 16.64mmHg for the TCM4 device and 1.31mmHg with agreement between -7.64 and 9.05mmHg for the TCM5 device. When accuracy was compared across time points for each patient, 46% of patients had an overnight accuracy change of ≥ 8mmHg when using the TCM4 compared with 20% when using the TCM5. It was concluded that the TcCO2 signal was un-reliable across the different monitors and that the TcCO2 trend may be difficult to interpret with confidence without blood gas calibration at the commencement and conclusion of the sleep study.
format Online
Article
Text
id pubmed-10109359
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-101093592023-05-15 P123 Accuracy and Reliability of the Transcutaneous Carbon Dioxide (TcCO2) Signal in the Sleep Laboratory Rossely, A Turton, A Roebuck, T Ho, S Naughton, M Mansfield, D Hamilton, G Sleep Adv Poster Presentations Carbon Dioxide (CO2) monitoring is an essential part of assessing and treating disorders of hypoventilation in the sleep laboratory. While reliablity issues have been previously reported with the Transcutaneous Carbon Dioxide (TcCO2) signal, there is limited data assessing the validity of this signal or its trend in the sleep laboratory context. Therefore, this study aimed to investigate the change in TcCO2 accuracy from the beginning to the end of the sleep study in real world conditions across two different Victorian public hospital sleep laboratories that used two different TcCO2 monitors. The sample included 13 consecutive patients from Monash Health and 44 consecutive patients from Alfred Health with an average age of 64 and 56 years respectively. Arterial Blood Gas (ABG) measurements were taken prior to and following each sleep study and compared concurrently with the TcCO2 value. Bland-Altman analysis revealed an average difference between TcCO2 and PaCO2 of 3.29mmHg with agreement between -11.44 and 16.64mmHg for the TCM4 device and 1.31mmHg with agreement between -7.64 and 9.05mmHg for the TCM5 device. When accuracy was compared across time points for each patient, 46% of patients had an overnight accuracy change of ≥ 8mmHg when using the TCM4 compared with 20% when using the TCM5. It was concluded that the TcCO2 signal was un-reliable across the different monitors and that the TcCO2 trend may be difficult to interpret with confidence without blood gas calibration at the commencement and conclusion of the sleep study. Oxford University Press 2021-10-07 /pmc/articles/PMC10109359/ http://dx.doi.org/10.1093/sleepadvances/zpab014.164 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of Sleep Research Society. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Poster Presentations
Rossely, A
Turton, A
Roebuck, T
Ho, S
Naughton, M
Mansfield, D
Hamilton, G
P123 Accuracy and Reliability of the Transcutaneous Carbon Dioxide (TcCO2) Signal in the Sleep Laboratory
title P123 Accuracy and Reliability of the Transcutaneous Carbon Dioxide (TcCO2) Signal in the Sleep Laboratory
title_full P123 Accuracy and Reliability of the Transcutaneous Carbon Dioxide (TcCO2) Signal in the Sleep Laboratory
title_fullStr P123 Accuracy and Reliability of the Transcutaneous Carbon Dioxide (TcCO2) Signal in the Sleep Laboratory
title_full_unstemmed P123 Accuracy and Reliability of the Transcutaneous Carbon Dioxide (TcCO2) Signal in the Sleep Laboratory
title_short P123 Accuracy and Reliability of the Transcutaneous Carbon Dioxide (TcCO2) Signal in the Sleep Laboratory
title_sort p123 accuracy and reliability of the transcutaneous carbon dioxide (tcco2) signal in the sleep laboratory
topic Poster Presentations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10109359/
http://dx.doi.org/10.1093/sleepadvances/zpab014.164
work_keys_str_mv AT rosselya p123accuracyandreliabilityofthetranscutaneouscarbondioxidetcco2signalinthesleeplaboratory
AT turtona p123accuracyandreliabilityofthetranscutaneouscarbondioxidetcco2signalinthesleeplaboratory
AT roebuckt p123accuracyandreliabilityofthetranscutaneouscarbondioxidetcco2signalinthesleeplaboratory
AT hos p123accuracyandreliabilityofthetranscutaneouscarbondioxidetcco2signalinthesleeplaboratory
AT naughtonm p123accuracyandreliabilityofthetranscutaneouscarbondioxidetcco2signalinthesleeplaboratory
AT mansfieldd p123accuracyandreliabilityofthetranscutaneouscarbondioxidetcco2signalinthesleeplaboratory
AT hamiltong p123accuracyandreliabilityofthetranscutaneouscarbondioxidetcco2signalinthesleeplaboratory