Cargando…
Comparison of prostate volume measured by transabdominal ultrasound and MRI with the radical prostatectomy specimen volume: a retrospective observational study
BACKGROUND: Few studies have compared the use of transabdominal ultrasound (TAUS) and magnetic resonance imaging (MRI) to measure prostate volume (PV). In this study, we evaluate the accuracy and reliability of PV measured by TAUS and MRI. METHODS: A total of 106 patients who underwent TAUS and MRI...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10111778/ https://www.ncbi.nlm.nih.gov/pubmed/37069539 http://dx.doi.org/10.1186/s12894-023-01234-5 |
_version_ | 1785027516324380672 |
---|---|
author | Guo, Shikuan Zhang, Jingliang Jiao, Jianhua Li, Zeyu Wu, Peng Jing, Yuming Qin, Weijun Wang, Fuli Ma, Shuaijun |
author_facet | Guo, Shikuan Zhang, Jingliang Jiao, Jianhua Li, Zeyu Wu, Peng Jing, Yuming Qin, Weijun Wang, Fuli Ma, Shuaijun |
author_sort | Guo, Shikuan |
collection | PubMed |
description | BACKGROUND: Few studies have compared the use of transabdominal ultrasound (TAUS) and magnetic resonance imaging (MRI) to measure prostate volume (PV). In this study, we evaluate the accuracy and reliability of PV measured by TAUS and MRI. METHODS: A total of 106 patients who underwent TAUS and MRI prior to radical prostatectomy were retrospectively analyzed. The TAUS-based and MRI-based PV were calculated using the ellipsoid formula. The specimen volume measured by the water-displacement method was used as a reference standard. Correlation analysis and intraclass correlation coefficients (ICC) were performed to compare different measurement methods and Bland Altman plots were drawn to assess the agreement. RESULTS: There was a high degree of correlation and agreement between the specimen volume and PV measured with TAUS (r = 0.838, p < 0.01; ICC = 0.83) and MRI (r = 0.914, p < 0.01; ICC = 0.90). TAUS overestimated specimen volume by 2.4ml, but the difference was independent of specimen volume (p = 0.19). MRI underestimated specimen volume by 1.7ml, the direction and magnitude of the difference varied with specimen volume (p < 0.01). The percentage error of PV measured by TAUS and MRI was within ± 20% in 65/106(61%) and 87/106(82%), respectively. In patients with PV greater than 50 ml, MRI volume still correlated strongly with specimen volume (r = 0.837, p < 0.01), while TAUS volume showed only moderate correlation with specimen (r = 0.665, p < 0.01) or MRI volume (r = 0.678, p < 0.01). CONCLUSIONS: This study demonstrated that PV measured by MRI and TAUS is highly correlated and reliable with the specimen volume. MRI might be a more appropriate choice for measuring the large prostate. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12894-023-01234-5. |
format | Online Article Text |
id | pubmed-10111778 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-101117782023-04-19 Comparison of prostate volume measured by transabdominal ultrasound and MRI with the radical prostatectomy specimen volume: a retrospective observational study Guo, Shikuan Zhang, Jingliang Jiao, Jianhua Li, Zeyu Wu, Peng Jing, Yuming Qin, Weijun Wang, Fuli Ma, Shuaijun BMC Urol Research BACKGROUND: Few studies have compared the use of transabdominal ultrasound (TAUS) and magnetic resonance imaging (MRI) to measure prostate volume (PV). In this study, we evaluate the accuracy and reliability of PV measured by TAUS and MRI. METHODS: A total of 106 patients who underwent TAUS and MRI prior to radical prostatectomy were retrospectively analyzed. The TAUS-based and MRI-based PV were calculated using the ellipsoid formula. The specimen volume measured by the water-displacement method was used as a reference standard. Correlation analysis and intraclass correlation coefficients (ICC) were performed to compare different measurement methods and Bland Altman plots were drawn to assess the agreement. RESULTS: There was a high degree of correlation and agreement between the specimen volume and PV measured with TAUS (r = 0.838, p < 0.01; ICC = 0.83) and MRI (r = 0.914, p < 0.01; ICC = 0.90). TAUS overestimated specimen volume by 2.4ml, but the difference was independent of specimen volume (p = 0.19). MRI underestimated specimen volume by 1.7ml, the direction and magnitude of the difference varied with specimen volume (p < 0.01). The percentage error of PV measured by TAUS and MRI was within ± 20% in 65/106(61%) and 87/106(82%), respectively. In patients with PV greater than 50 ml, MRI volume still correlated strongly with specimen volume (r = 0.837, p < 0.01), while TAUS volume showed only moderate correlation with specimen (r = 0.665, p < 0.01) or MRI volume (r = 0.678, p < 0.01). CONCLUSIONS: This study demonstrated that PV measured by MRI and TAUS is highly correlated and reliable with the specimen volume. MRI might be a more appropriate choice for measuring the large prostate. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12894-023-01234-5. BioMed Central 2023-04-17 /pmc/articles/PMC10111778/ /pubmed/37069539 http://dx.doi.org/10.1186/s12894-023-01234-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Guo, Shikuan Zhang, Jingliang Jiao, Jianhua Li, Zeyu Wu, Peng Jing, Yuming Qin, Weijun Wang, Fuli Ma, Shuaijun Comparison of prostate volume measured by transabdominal ultrasound and MRI with the radical prostatectomy specimen volume: a retrospective observational study |
title | Comparison of prostate volume measured by transabdominal ultrasound and MRI with the radical prostatectomy specimen volume: a retrospective observational study |
title_full | Comparison of prostate volume measured by transabdominal ultrasound and MRI with the radical prostatectomy specimen volume: a retrospective observational study |
title_fullStr | Comparison of prostate volume measured by transabdominal ultrasound and MRI with the radical prostatectomy specimen volume: a retrospective observational study |
title_full_unstemmed | Comparison of prostate volume measured by transabdominal ultrasound and MRI with the radical prostatectomy specimen volume: a retrospective observational study |
title_short | Comparison of prostate volume measured by transabdominal ultrasound and MRI with the radical prostatectomy specimen volume: a retrospective observational study |
title_sort | comparison of prostate volume measured by transabdominal ultrasound and mri with the radical prostatectomy specimen volume: a retrospective observational study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10111778/ https://www.ncbi.nlm.nih.gov/pubmed/37069539 http://dx.doi.org/10.1186/s12894-023-01234-5 |
work_keys_str_mv | AT guoshikuan comparisonofprostatevolumemeasuredbytransabdominalultrasoundandmriwiththeradicalprostatectomyspecimenvolumearetrospectiveobservationalstudy AT zhangjingliang comparisonofprostatevolumemeasuredbytransabdominalultrasoundandmriwiththeradicalprostatectomyspecimenvolumearetrospectiveobservationalstudy AT jiaojianhua comparisonofprostatevolumemeasuredbytransabdominalultrasoundandmriwiththeradicalprostatectomyspecimenvolumearetrospectiveobservationalstudy AT lizeyu comparisonofprostatevolumemeasuredbytransabdominalultrasoundandmriwiththeradicalprostatectomyspecimenvolumearetrospectiveobservationalstudy AT wupeng comparisonofprostatevolumemeasuredbytransabdominalultrasoundandmriwiththeradicalprostatectomyspecimenvolumearetrospectiveobservationalstudy AT jingyuming comparisonofprostatevolumemeasuredbytransabdominalultrasoundandmriwiththeradicalprostatectomyspecimenvolumearetrospectiveobservationalstudy AT qinweijun comparisonofprostatevolumemeasuredbytransabdominalultrasoundandmriwiththeradicalprostatectomyspecimenvolumearetrospectiveobservationalstudy AT wangfuli comparisonofprostatevolumemeasuredbytransabdominalultrasoundandmriwiththeradicalprostatectomyspecimenvolumearetrospectiveobservationalstudy AT mashuaijun comparisonofprostatevolumemeasuredbytransabdominalultrasoundandmriwiththeradicalprostatectomyspecimenvolumearetrospectiveobservationalstudy |