Biomechanical evaluation of interlocking nail and locking compression plating for stabilization of ovine critical-sized segmental tibia defects

BACKGROUND: Segmental large volume bone loss resulting from fracture or osseous neoplasia is a major challenge to orthopedic surgeons and there is an ongoing quest to identify treatments that optimize healing. To advance treatment, large animal translational models—such as the ovine critical-sized t...

Descripción completa

Detalles Bibliográficos
Autores principales: Koch, Drew W., Johnson, James W., Smith, Quinn E., Brekhus, Chloe, Gadomski, Benjamin C., Palmer, Ross H., Easley, Jeremiah T., Nelson, Brad B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10113068/
https://www.ncbi.nlm.nih.gov/pubmed/37082686
http://dx.doi.org/10.21037/atm-22-4886
_version_ 1785027745075429376
author Koch, Drew W.
Johnson, James W.
Smith, Quinn E.
Brekhus, Chloe
Gadomski, Benjamin C.
Palmer, Ross H.
Easley, Jeremiah T.
Nelson, Brad B.
author_facet Koch, Drew W.
Johnson, James W.
Smith, Quinn E.
Brekhus, Chloe
Gadomski, Benjamin C.
Palmer, Ross H.
Easley, Jeremiah T.
Nelson, Brad B.
author_sort Koch, Drew W.
collection PubMed
description BACKGROUND: Segmental large volume bone loss resulting from fracture or osseous neoplasia is a major challenge to orthopedic surgeons and there is an ongoing quest to identify treatments that optimize healing. To advance treatment, large animal translational models—such as the ovine critical-sized tibia defect model—are instrumental for testing of novel scaffolds for bone regeneration. However, little standardization in the implants utilized for defect stabilization has been determined and current commercially available implants may be inadequate to replicate the strength of the native tibia. We hypothesize that a 10-mm interlocking nail (ILN) would be stiffer in axial, bending, and torsional loading than its 8-mm counterpart and would be stiffer in axial and torsional loading compared to a 4.5-mm broad locking compression plate (LCP). METHODS: Tibias were harvested from 24 ovine hind limbs from skeletally mature ewes euthanized for reasons unrelated to this study and were randomized to treatment group. An ex vivo comparison of a novel 10-mm angle-stable non-tapered ILN was compared to a commercially available 8-mm angle-stable tapered ILN and a broad LCP in an ovine critical-sized (5-cm) tibia defect model. Axial stiffness, torsional stiffness, and bending stiffness were determined in control intact tibia and tibial constructs in the three treatment groups. Following implantation, radiography was performed in all limbs and tibia length and cortical and medullary cavity diameter were measured. Comparisons between groups were assessed with a one-way analysis of variance. Significance was set at P<0.05. RESULTS: The 10-mm ILN in tibia containing a 5-cm ostectomy gap most closely replicated the structural properties of intact tibia compared with other constructs. The 10-mm ILN had significantly stronger torsional (P<0.001) and bending (P=0.002) stiffness than the 8-mm ILN, and was significantly stronger than the LCP in axial (P=0.04) and torsional (P=0.01) stiffness. CONCLUSIONS: A 10-mm ILN used to stabilize an ovine critically-sized tibia defect most closely mimicked the structural properties of the intact tibia when compared to a 8-mm ILN or broad LCP. Further in vivo testing will aid in determining which stabilization method is best suited for testing of novel tissue engineering and bone healing studies.
format Online
Article
Text
id pubmed-10113068
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-101130682023-04-19 Biomechanical evaluation of interlocking nail and locking compression plating for stabilization of ovine critical-sized segmental tibia defects Koch, Drew W. Johnson, James W. Smith, Quinn E. Brekhus, Chloe Gadomski, Benjamin C. Palmer, Ross H. Easley, Jeremiah T. Nelson, Brad B. Ann Transl Med Original Article BACKGROUND: Segmental large volume bone loss resulting from fracture or osseous neoplasia is a major challenge to orthopedic surgeons and there is an ongoing quest to identify treatments that optimize healing. To advance treatment, large animal translational models—such as the ovine critical-sized tibia defect model—are instrumental for testing of novel scaffolds for bone regeneration. However, little standardization in the implants utilized for defect stabilization has been determined and current commercially available implants may be inadequate to replicate the strength of the native tibia. We hypothesize that a 10-mm interlocking nail (ILN) would be stiffer in axial, bending, and torsional loading than its 8-mm counterpart and would be stiffer in axial and torsional loading compared to a 4.5-mm broad locking compression plate (LCP). METHODS: Tibias were harvested from 24 ovine hind limbs from skeletally mature ewes euthanized for reasons unrelated to this study and were randomized to treatment group. An ex vivo comparison of a novel 10-mm angle-stable non-tapered ILN was compared to a commercially available 8-mm angle-stable tapered ILN and a broad LCP in an ovine critical-sized (5-cm) tibia defect model. Axial stiffness, torsional stiffness, and bending stiffness were determined in control intact tibia and tibial constructs in the three treatment groups. Following implantation, radiography was performed in all limbs and tibia length and cortical and medullary cavity diameter were measured. Comparisons between groups were assessed with a one-way analysis of variance. Significance was set at P<0.05. RESULTS: The 10-mm ILN in tibia containing a 5-cm ostectomy gap most closely replicated the structural properties of intact tibia compared with other constructs. The 10-mm ILN had significantly stronger torsional (P<0.001) and bending (P=0.002) stiffness than the 8-mm ILN, and was significantly stronger than the LCP in axial (P=0.04) and torsional (P=0.01) stiffness. CONCLUSIONS: A 10-mm ILN used to stabilize an ovine critically-sized tibia defect most closely mimicked the structural properties of the intact tibia when compared to a 8-mm ILN or broad LCP. Further in vivo testing will aid in determining which stabilization method is best suited for testing of novel tissue engineering and bone healing studies. AME Publishing Company 2023-03-15 2023-03-31 /pmc/articles/PMC10113068/ /pubmed/37082686 http://dx.doi.org/10.21037/atm-22-4886 Text en 2023 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Koch, Drew W.
Johnson, James W.
Smith, Quinn E.
Brekhus, Chloe
Gadomski, Benjamin C.
Palmer, Ross H.
Easley, Jeremiah T.
Nelson, Brad B.
Biomechanical evaluation of interlocking nail and locking compression plating for stabilization of ovine critical-sized segmental tibia defects
title Biomechanical evaluation of interlocking nail and locking compression plating for stabilization of ovine critical-sized segmental tibia defects
title_full Biomechanical evaluation of interlocking nail and locking compression plating for stabilization of ovine critical-sized segmental tibia defects
title_fullStr Biomechanical evaluation of interlocking nail and locking compression plating for stabilization of ovine critical-sized segmental tibia defects
title_full_unstemmed Biomechanical evaluation of interlocking nail and locking compression plating for stabilization of ovine critical-sized segmental tibia defects
title_short Biomechanical evaluation of interlocking nail and locking compression plating for stabilization of ovine critical-sized segmental tibia defects
title_sort biomechanical evaluation of interlocking nail and locking compression plating for stabilization of ovine critical-sized segmental tibia defects
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10113068/
https://www.ncbi.nlm.nih.gov/pubmed/37082686
http://dx.doi.org/10.21037/atm-22-4886
work_keys_str_mv AT kochdreww biomechanicalevaluationofinterlockingnailandlockingcompressionplatingforstabilizationofovinecriticalsizedsegmentaltibiadefects
AT johnsonjamesw biomechanicalevaluationofinterlockingnailandlockingcompressionplatingforstabilizationofovinecriticalsizedsegmentaltibiadefects
AT smithquinne biomechanicalevaluationofinterlockingnailandlockingcompressionplatingforstabilizationofovinecriticalsizedsegmentaltibiadefects
AT brekhuschloe biomechanicalevaluationofinterlockingnailandlockingcompressionplatingforstabilizationofovinecriticalsizedsegmentaltibiadefects
AT gadomskibenjaminc biomechanicalevaluationofinterlockingnailandlockingcompressionplatingforstabilizationofovinecriticalsizedsegmentaltibiadefects
AT palmerrossh biomechanicalevaluationofinterlockingnailandlockingcompressionplatingforstabilizationofovinecriticalsizedsegmentaltibiadefects
AT easleyjeremiaht biomechanicalevaluationofinterlockingnailandlockingcompressionplatingforstabilizationofovinecriticalsizedsegmentaltibiadefects
AT nelsonbradb biomechanicalevaluationofinterlockingnailandlockingcompressionplatingforstabilizationofovinecriticalsizedsegmentaltibiadefects