Cargando…
Reducing PTV margins for prostate SBRT with motion compensation and gating techniques
The purpose of this study is to investigate the dosimetric accuracy of prostate SBRT when motion is considered. To account for target movement, motion compensation and gating techniques were investigated with PTV margins reduced to 2 mm. To allow for dosimetric measurements a Delta4 phantom, Gafchro...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10113684/ https://www.ncbi.nlm.nih.gov/pubmed/36478148 http://dx.doi.org/10.1002/acm2.13861 |
_version_ | 1785027895415013376 |
---|---|
author | Goddard, Lee Jeong, Kyoungkeun Tang, Justin Garg, Madhur Tomé, Wolfgang A. |
author_facet | Goddard, Lee Jeong, Kyoungkeun Tang, Justin Garg, Madhur Tomé, Wolfgang A. |
author_sort | Goddard, Lee |
collection | PubMed |
description | The purpose of this study is to investigate the dosimetric accuracy of prostate SBRT when motion is considered. To account for target movement, motion compensation and gating techniques were investigated with PTV margins reduced to 2 mm. To allow for dosimetric measurements a Delta4 phantom, Gafchromic film, and Hexamotion motion platform were utilized. Four motion files were utilized that represent a range of motions. Analysis of measured prostate motions for fifteen patients was performed to ensure detected motions were similar to those previously reported and motion files utilized were suitable. Five patient plans were utilized to allow for the effects of MLC and target motion interplay to be investigated. For both motion compensation and gating techniques, plans were delivered to the stationary phantom and for each of four motion types with/without compensation/gating enabled. Using a 3%, 2 mm and 80% threshold gamma criteria, film measurements had an average pass rate of 80.5% for uncorrected deliveries versus 96.0% for motion compensated deliveries. For gated techniques average pass rates increased from 89.9% for uncorrected to 94.8% with gating enabled. Measurements with the Delta4 arrays were analyzed with a 3%, 2 mm and 10% threshold dose. An average pass rate of 83.8% was measured for uncorrected motions versus 94.8% with motion compensation. For the gated technique an average pass rate of 87.2% was found for uncorrected motions versus 96.9% with gating enabled. These results show that very high gamma pass rates are achievable when motion compensation or gating techniques are applied. When target motion is not accounted for shifts up to 5 mm in planned versus delivered isodose distributions were found. However, when motion compensation, or gated techniques were applied, much smaller differences between planned and delivered isodose distributions were found. With these techniques dose delivery accuracy is greatly improved, allowing for PTV margins to be reduced. |
format | Online Article Text |
id | pubmed-10113684 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-101136842023-04-20 Reducing PTV margins for prostate SBRT with motion compensation and gating techniques Goddard, Lee Jeong, Kyoungkeun Tang, Justin Garg, Madhur Tomé, Wolfgang A. J Appl Clin Med Phys Radiation Oncology Physics The purpose of this study is to investigate the dosimetric accuracy of prostate SBRT when motion is considered. To account for target movement, motion compensation and gating techniques were investigated with PTV margins reduced to 2 mm. To allow for dosimetric measurements a Delta4 phantom, Gafchromic film, and Hexamotion motion platform were utilized. Four motion files were utilized that represent a range of motions. Analysis of measured prostate motions for fifteen patients was performed to ensure detected motions were similar to those previously reported and motion files utilized were suitable. Five patient plans were utilized to allow for the effects of MLC and target motion interplay to be investigated. For both motion compensation and gating techniques, plans were delivered to the stationary phantom and for each of four motion types with/without compensation/gating enabled. Using a 3%, 2 mm and 80% threshold gamma criteria, film measurements had an average pass rate of 80.5% for uncorrected deliveries versus 96.0% for motion compensated deliveries. For gated techniques average pass rates increased from 89.9% for uncorrected to 94.8% with gating enabled. Measurements with the Delta4 arrays were analyzed with a 3%, 2 mm and 10% threshold dose. An average pass rate of 83.8% was measured for uncorrected motions versus 94.8% with motion compensation. For the gated technique an average pass rate of 87.2% was found for uncorrected motions versus 96.9% with gating enabled. These results show that very high gamma pass rates are achievable when motion compensation or gating techniques are applied. When target motion is not accounted for shifts up to 5 mm in planned versus delivered isodose distributions were found. However, when motion compensation, or gated techniques were applied, much smaller differences between planned and delivered isodose distributions were found. With these techniques dose delivery accuracy is greatly improved, allowing for PTV margins to be reduced. John Wiley and Sons Inc. 2022-12-07 /pmc/articles/PMC10113684/ /pubmed/36478148 http://dx.doi.org/10.1002/acm2.13861 Text en © 2022 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Goddard, Lee Jeong, Kyoungkeun Tang, Justin Garg, Madhur Tomé, Wolfgang A. Reducing PTV margins for prostate SBRT with motion compensation and gating techniques |
title | Reducing PTV margins for prostate SBRT with motion compensation and gating techniques |
title_full | Reducing PTV margins for prostate SBRT with motion compensation and gating techniques |
title_fullStr | Reducing PTV margins for prostate SBRT with motion compensation and gating techniques |
title_full_unstemmed | Reducing PTV margins for prostate SBRT with motion compensation and gating techniques |
title_short | Reducing PTV margins for prostate SBRT with motion compensation and gating techniques |
title_sort | reducing ptv margins for prostate sbrt with motion compensation and gating techniques |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10113684/ https://www.ncbi.nlm.nih.gov/pubmed/36478148 http://dx.doi.org/10.1002/acm2.13861 |
work_keys_str_mv | AT goddardlee reducingptvmarginsforprostatesbrtwithmotioncompensationandgatingtechniques AT jeongkyoungkeun reducingptvmarginsforprostatesbrtwithmotioncompensationandgatingtechniques AT tangjustin reducingptvmarginsforprostatesbrtwithmotioncompensationandgatingtechniques AT gargmadhur reducingptvmarginsforprostatesbrtwithmotioncompensationandgatingtechniques AT tomewolfganga reducingptvmarginsforprostatesbrtwithmotioncompensationandgatingtechniques |