Cargando…

Development of revised ResNet-50 for diabetic retinopathy detection

BACKGROUND: Diabetic retinopathy (DR) produces bleeding, exudation, and new blood vessel formation conditions. DR can damage the retinal blood vessels and cause vision loss or even blindness. If DR is detected early, ophthalmologists can use lasers to create tiny burns around the retinal tears to in...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Chun-Ling, Wu, Kun-Chi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10114328/
https://www.ncbi.nlm.nih.gov/pubmed/37076790
http://dx.doi.org/10.1186/s12859-023-05293-1
_version_ 1785027992167120896
author Lin, Chun-Ling
Wu, Kun-Chi
author_facet Lin, Chun-Ling
Wu, Kun-Chi
author_sort Lin, Chun-Ling
collection PubMed
description BACKGROUND: Diabetic retinopathy (DR) produces bleeding, exudation, and new blood vessel formation conditions. DR can damage the retinal blood vessels and cause vision loss or even blindness. If DR is detected early, ophthalmologists can use lasers to create tiny burns around the retinal tears to inhibit bleeding and prevent the formation of new blood vessels, in order to prevent deterioration of the disease. The rapid improvement of deep learning has made image recognition an effective technology; it can avoid misjudgments caused by different doctors’ evaluations and help doctors to predict the condition quickly. The aim of this paper is to adopt visualization and preprocessing in the ResNet-50 model to improve module calibration, to enable the model to predict DR accurately. RESULTS: This study compared the performance of the proposed method with other common CNNs models (Xception, AlexNet, VggNet-s, VggNet-16 and ResNet-50). In examining said models, the results alluded to an over-fitting phenomenon, and the outcome of the work demonstrates that the performance of the revised ResNet-50 (Train accuracy: 0.8395 and Test accuracy: 0.7432) is better than other common CNNs (that is, the revised structure of ResNet-50 could avoid the overfitting problem, decease the loss value, and reduce the fluctuation problem). CONCLUSIONS: This study proposed two approaches to designing the DR grading system: a standard operation procedure (SOP) for preprocessing the fundus image, and a revised structure of ResNet-50, including an adaptive learning rating to adjust the weight of layers, regularization and change the structure of ResNet-50, which was selected for its suitable features. It is worth noting that the purpose of this study was not to design the most accurate DR screening network, but to demonstrate the effect of the SOP of DR and the visualization of the revised ResNet-50 model. The results provided an insight to revise the structure of CNNs using the visualization tool.
format Online
Article
Text
id pubmed-10114328
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-101143282023-04-20 Development of revised ResNet-50 for diabetic retinopathy detection Lin, Chun-Ling Wu, Kun-Chi BMC Bioinformatics Research BACKGROUND: Diabetic retinopathy (DR) produces bleeding, exudation, and new blood vessel formation conditions. DR can damage the retinal blood vessels and cause vision loss or even blindness. If DR is detected early, ophthalmologists can use lasers to create tiny burns around the retinal tears to inhibit bleeding and prevent the formation of new blood vessels, in order to prevent deterioration of the disease. The rapid improvement of deep learning has made image recognition an effective technology; it can avoid misjudgments caused by different doctors’ evaluations and help doctors to predict the condition quickly. The aim of this paper is to adopt visualization and preprocessing in the ResNet-50 model to improve module calibration, to enable the model to predict DR accurately. RESULTS: This study compared the performance of the proposed method with other common CNNs models (Xception, AlexNet, VggNet-s, VggNet-16 and ResNet-50). In examining said models, the results alluded to an over-fitting phenomenon, and the outcome of the work demonstrates that the performance of the revised ResNet-50 (Train accuracy: 0.8395 and Test accuracy: 0.7432) is better than other common CNNs (that is, the revised structure of ResNet-50 could avoid the overfitting problem, decease the loss value, and reduce the fluctuation problem). CONCLUSIONS: This study proposed two approaches to designing the DR grading system: a standard operation procedure (SOP) for preprocessing the fundus image, and a revised structure of ResNet-50, including an adaptive learning rating to adjust the weight of layers, regularization and change the structure of ResNet-50, which was selected for its suitable features. It is worth noting that the purpose of this study was not to design the most accurate DR screening network, but to demonstrate the effect of the SOP of DR and the visualization of the revised ResNet-50 model. The results provided an insight to revise the structure of CNNs using the visualization tool. BioMed Central 2023-04-19 /pmc/articles/PMC10114328/ /pubmed/37076790 http://dx.doi.org/10.1186/s12859-023-05293-1 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Lin, Chun-Ling
Wu, Kun-Chi
Development of revised ResNet-50 for diabetic retinopathy detection
title Development of revised ResNet-50 for diabetic retinopathy detection
title_full Development of revised ResNet-50 for diabetic retinopathy detection
title_fullStr Development of revised ResNet-50 for diabetic retinopathy detection
title_full_unstemmed Development of revised ResNet-50 for diabetic retinopathy detection
title_short Development of revised ResNet-50 for diabetic retinopathy detection
title_sort development of revised resnet-50 for diabetic retinopathy detection
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10114328/
https://www.ncbi.nlm.nih.gov/pubmed/37076790
http://dx.doi.org/10.1186/s12859-023-05293-1
work_keys_str_mv AT linchunling developmentofrevisedresnet50fordiabeticretinopathydetection
AT wukunchi developmentofrevisedresnet50fordiabeticretinopathydetection