Cargando…

Safety and feasibility of a novel bi-directional portal vein access kit during transjugular intrahepatic portosystemic shunt creation

BACKGROUND: Transjugular intrahepatic portosystemic shunt (TIPS) creation remains as one of the more technically challenging endovascular procedures. Portal vein access from the hepatic vein often requires multiple needle passes, which increases procedure times, risk of complications, and radiation...

Descripción completa

Detalles Bibliográficos
Autores principales: Kang, Richard D., Nezami, Nariman, Park, Peter, DePalma, Anthony A., Loya, Mohammed F., Mhaskar, Rahul, Engel, Chad, Zwiebel, Bruce, Hoots, Glenn, Shaikh, Jamil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10115920/
https://www.ncbi.nlm.nih.gov/pubmed/37074479
http://dx.doi.org/10.1186/s42155-023-00366-x
_version_ 1785028309956952064
author Kang, Richard D.
Nezami, Nariman
Park, Peter
DePalma, Anthony A.
Loya, Mohammed F.
Mhaskar, Rahul
Engel, Chad
Zwiebel, Bruce
Hoots, Glenn
Shaikh, Jamil
author_facet Kang, Richard D.
Nezami, Nariman
Park, Peter
DePalma, Anthony A.
Loya, Mohammed F.
Mhaskar, Rahul
Engel, Chad
Zwiebel, Bruce
Hoots, Glenn
Shaikh, Jamil
author_sort Kang, Richard D.
collection PubMed
description BACKGROUND: Transjugular intrahepatic portosystemic shunt (TIPS) creation remains as one of the more technically challenging endovascular procedures. Portal vein access from the hepatic vein often requires multiple needle passes, which increases procedure times, risk of complications, and radiation exposure. With its bi-directional maneuverability, the Scorpion X access kit may be a promising tool for easier portal vein access. However, the clinical safety and feasibility of this access kit has yet to be determined. MATERIALS AND METHODS: In this retrospective study, 17 patients (12 male, average age 56.6 ± 9.01) underwent TIPS procedure using Scorpion X portal vein access kits. The primary endpoint was time taken to access the portal vein from the hepatic vein. The most common indications for TIPS were refractory ascites (47.1%) and esophageal varices (17.6%). Radiation exposure, total number of needle passes, and intraoperative complications were recorded. Average MELD Score was 12.6 ± 3.39 (range: 8–20). RESULTS: Portal vein cannulation was successfully achieved in 100% of patients during intracardiac echocardiography-assisted TIPS creation. Total fluoroscopy time was 39.31 ± 17.97 min; average radiation dose was 1036.76 ± 644.15 mGy, while average contrast dose was 120.59 ± 56.87 mL. The average number of passes from the hepatic vein to the portal vein was 2 (range: 1–6). Average time to access the portal vein once the TIPS cannula was positioned in the hepatic vein was 30.65 ± 18.64 min. There were no intraoperative complications. CONCLUSIONS: Clinical utilization of the Scorpion X bi-directional portal vein access kit is both safe and feasible. Utilizing this bi-directional access kit resulted in successful portal vein access with minimal intraoperative complications. LEVEL OF EVIDENCE: Retrospective cohort.
format Online
Article
Text
id pubmed-10115920
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-101159202023-04-21 Safety and feasibility of a novel bi-directional portal vein access kit during transjugular intrahepatic portosystemic shunt creation Kang, Richard D. Nezami, Nariman Park, Peter DePalma, Anthony A. Loya, Mohammed F. Mhaskar, Rahul Engel, Chad Zwiebel, Bruce Hoots, Glenn Shaikh, Jamil CVIR Endovasc Original Article BACKGROUND: Transjugular intrahepatic portosystemic shunt (TIPS) creation remains as one of the more technically challenging endovascular procedures. Portal vein access from the hepatic vein often requires multiple needle passes, which increases procedure times, risk of complications, and radiation exposure. With its bi-directional maneuverability, the Scorpion X access kit may be a promising tool for easier portal vein access. However, the clinical safety and feasibility of this access kit has yet to be determined. MATERIALS AND METHODS: In this retrospective study, 17 patients (12 male, average age 56.6 ± 9.01) underwent TIPS procedure using Scorpion X portal vein access kits. The primary endpoint was time taken to access the portal vein from the hepatic vein. The most common indications for TIPS were refractory ascites (47.1%) and esophageal varices (17.6%). Radiation exposure, total number of needle passes, and intraoperative complications were recorded. Average MELD Score was 12.6 ± 3.39 (range: 8–20). RESULTS: Portal vein cannulation was successfully achieved in 100% of patients during intracardiac echocardiography-assisted TIPS creation. Total fluoroscopy time was 39.31 ± 17.97 min; average radiation dose was 1036.76 ± 644.15 mGy, while average contrast dose was 120.59 ± 56.87 mL. The average number of passes from the hepatic vein to the portal vein was 2 (range: 1–6). Average time to access the portal vein once the TIPS cannula was positioned in the hepatic vein was 30.65 ± 18.64 min. There were no intraoperative complications. CONCLUSIONS: Clinical utilization of the Scorpion X bi-directional portal vein access kit is both safe and feasible. Utilizing this bi-directional access kit resulted in successful portal vein access with minimal intraoperative complications. LEVEL OF EVIDENCE: Retrospective cohort. Springer International Publishing 2023-04-19 /pmc/articles/PMC10115920/ /pubmed/37074479 http://dx.doi.org/10.1186/s42155-023-00366-x Text en © This is a U.S. Government work and not under copyright protection in the US; foreign copyright protection may apply 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Kang, Richard D.
Nezami, Nariman
Park, Peter
DePalma, Anthony A.
Loya, Mohammed F.
Mhaskar, Rahul
Engel, Chad
Zwiebel, Bruce
Hoots, Glenn
Shaikh, Jamil
Safety and feasibility of a novel bi-directional portal vein access kit during transjugular intrahepatic portosystemic shunt creation
title Safety and feasibility of a novel bi-directional portal vein access kit during transjugular intrahepatic portosystemic shunt creation
title_full Safety and feasibility of a novel bi-directional portal vein access kit during transjugular intrahepatic portosystemic shunt creation
title_fullStr Safety and feasibility of a novel bi-directional portal vein access kit during transjugular intrahepatic portosystemic shunt creation
title_full_unstemmed Safety and feasibility of a novel bi-directional portal vein access kit during transjugular intrahepatic portosystemic shunt creation
title_short Safety and feasibility of a novel bi-directional portal vein access kit during transjugular intrahepatic portosystemic shunt creation
title_sort safety and feasibility of a novel bi-directional portal vein access kit during transjugular intrahepatic portosystemic shunt creation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10115920/
https://www.ncbi.nlm.nih.gov/pubmed/37074479
http://dx.doi.org/10.1186/s42155-023-00366-x
work_keys_str_mv AT kangrichardd safetyandfeasibilityofanovelbidirectionalportalveinaccesskitduringtransjugularintrahepaticportosystemicshuntcreation
AT nezaminariman safetyandfeasibilityofanovelbidirectionalportalveinaccesskitduringtransjugularintrahepaticportosystemicshuntcreation
AT parkpeter safetyandfeasibilityofanovelbidirectionalportalveinaccesskitduringtransjugularintrahepaticportosystemicshuntcreation
AT depalmaanthonya safetyandfeasibilityofanovelbidirectionalportalveinaccesskitduringtransjugularintrahepaticportosystemicshuntcreation
AT loyamohammedf safetyandfeasibilityofanovelbidirectionalportalveinaccesskitduringtransjugularintrahepaticportosystemicshuntcreation
AT mhaskarrahul safetyandfeasibilityofanovelbidirectionalportalveinaccesskitduringtransjugularintrahepaticportosystemicshuntcreation
AT engelchad safetyandfeasibilityofanovelbidirectionalportalveinaccesskitduringtransjugularintrahepaticportosystemicshuntcreation
AT zwiebelbruce safetyandfeasibilityofanovelbidirectionalportalveinaccesskitduringtransjugularintrahepaticportosystemicshuntcreation
AT hootsglenn safetyandfeasibilityofanovelbidirectionalportalveinaccesskitduringtransjugularintrahepaticportosystemicshuntcreation
AT shaikhjamil safetyandfeasibilityofanovelbidirectionalportalveinaccesskitduringtransjugularintrahepaticportosystemicshuntcreation