Cargando…

An Improved Method for Determining Urease Activity from Electrical Conductivity Measurements

[Image: see text] We present an improved approach to evaluating the activity of urease from electrical conductivity (EC) measurements. In this approach, chemical equilibrium modeling via PHREEQC is used in conjunction with empirical equations for computing EC to develop a function that relates the i...

Descripción completa

Detalles Bibliográficos
Autores principales: Krishnan, Vinay, Khodadadi Tirkolaei, Hamed, Kavazanjian, Edward
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2023
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10116633/
https://www.ncbi.nlm.nih.gov/pubmed/37091411
http://dx.doi.org/10.1021/acsomega.2c08152
_version_ 1785028467078725632
author Krishnan, Vinay
Khodadadi Tirkolaei, Hamed
Kavazanjian, Edward
author_facet Krishnan, Vinay
Khodadadi Tirkolaei, Hamed
Kavazanjian, Edward
author_sort Krishnan, Vinay
collection PubMed
description [Image: see text] We present an improved approach to evaluating the activity of urease from electrical conductivity (EC) measurements. In this approach, chemical equilibrium modeling via PHREEQC is used in conjunction with empirical equations for computing EC to develop a function that relates the increase in EC during urea hydrolysis in a closed reactor to the concentration of ammonium species present (and concentration of urea remaining) in the reaction solution. By applying this function to data from continuous measurement of EC during urea hydrolysis, we obtain a profile of the concentration of the urea substrate with time, which is then used to determine the urease activity. The activity of commercially available urease extracted from jack beans was determined using this method and compared well to the activity determined using Nessler’s reagent, a commonly used colorimetric assay. This EC-based method is inexpensive and can be used for accurate determination of urease activity for a variety of applications.
format Online
Article
Text
id pubmed-10116633
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-101166332023-04-21 An Improved Method for Determining Urease Activity from Electrical Conductivity Measurements Krishnan, Vinay Khodadadi Tirkolaei, Hamed Kavazanjian, Edward ACS Omega [Image: see text] We present an improved approach to evaluating the activity of urease from electrical conductivity (EC) measurements. In this approach, chemical equilibrium modeling via PHREEQC is used in conjunction with empirical equations for computing EC to develop a function that relates the increase in EC during urea hydrolysis in a closed reactor to the concentration of ammonium species present (and concentration of urea remaining) in the reaction solution. By applying this function to data from continuous measurement of EC during urea hydrolysis, we obtain a profile of the concentration of the urea substrate with time, which is then used to determine the urease activity. The activity of commercially available urease extracted from jack beans was determined using this method and compared well to the activity determined using Nessler’s reagent, a commonly used colorimetric assay. This EC-based method is inexpensive and can be used for accurate determination of urease activity for a variety of applications. American Chemical Society 2023-04-06 /pmc/articles/PMC10116633/ /pubmed/37091411 http://dx.doi.org/10.1021/acsomega.2c08152 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Krishnan, Vinay
Khodadadi Tirkolaei, Hamed
Kavazanjian, Edward
An Improved Method for Determining Urease Activity from Electrical Conductivity Measurements
title An Improved Method for Determining Urease Activity from Electrical Conductivity Measurements
title_full An Improved Method for Determining Urease Activity from Electrical Conductivity Measurements
title_fullStr An Improved Method for Determining Urease Activity from Electrical Conductivity Measurements
title_full_unstemmed An Improved Method for Determining Urease Activity from Electrical Conductivity Measurements
title_short An Improved Method for Determining Urease Activity from Electrical Conductivity Measurements
title_sort improved method for determining urease activity from electrical conductivity measurements
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10116633/
https://www.ncbi.nlm.nih.gov/pubmed/37091411
http://dx.doi.org/10.1021/acsomega.2c08152
work_keys_str_mv AT krishnanvinay animprovedmethodfordeterminingureaseactivityfromelectricalconductivitymeasurements
AT khodadaditirkolaeihamed animprovedmethodfordeterminingureaseactivityfromelectricalconductivitymeasurements
AT kavazanjianedward animprovedmethodfordeterminingureaseactivityfromelectricalconductivitymeasurements
AT krishnanvinay improvedmethodfordeterminingureaseactivityfromelectricalconductivitymeasurements
AT khodadaditirkolaeihamed improvedmethodfordeterminingureaseactivityfromelectricalconductivitymeasurements
AT kavazanjianedward improvedmethodfordeterminingureaseactivityfromelectricalconductivitymeasurements