Cargando…
An Improved Method for Determining Urease Activity from Electrical Conductivity Measurements
[Image: see text] We present an improved approach to evaluating the activity of urease from electrical conductivity (EC) measurements. In this approach, chemical equilibrium modeling via PHREEQC is used in conjunction with empirical equations for computing EC to develop a function that relates the i...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2023
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10116633/ https://www.ncbi.nlm.nih.gov/pubmed/37091411 http://dx.doi.org/10.1021/acsomega.2c08152 |
_version_ | 1785028467078725632 |
---|---|
author | Krishnan, Vinay Khodadadi Tirkolaei, Hamed Kavazanjian, Edward |
author_facet | Krishnan, Vinay Khodadadi Tirkolaei, Hamed Kavazanjian, Edward |
author_sort | Krishnan, Vinay |
collection | PubMed |
description | [Image: see text] We present an improved approach to evaluating the activity of urease from electrical conductivity (EC) measurements. In this approach, chemical equilibrium modeling via PHREEQC is used in conjunction with empirical equations for computing EC to develop a function that relates the increase in EC during urea hydrolysis in a closed reactor to the concentration of ammonium species present (and concentration of urea remaining) in the reaction solution. By applying this function to data from continuous measurement of EC during urea hydrolysis, we obtain a profile of the concentration of the urea substrate with time, which is then used to determine the urease activity. The activity of commercially available urease extracted from jack beans was determined using this method and compared well to the activity determined using Nessler’s reagent, a commonly used colorimetric assay. This EC-based method is inexpensive and can be used for accurate determination of urease activity for a variety of applications. |
format | Online Article Text |
id | pubmed-10116633 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-101166332023-04-21 An Improved Method for Determining Urease Activity from Electrical Conductivity Measurements Krishnan, Vinay Khodadadi Tirkolaei, Hamed Kavazanjian, Edward ACS Omega [Image: see text] We present an improved approach to evaluating the activity of urease from electrical conductivity (EC) measurements. In this approach, chemical equilibrium modeling via PHREEQC is used in conjunction with empirical equations for computing EC to develop a function that relates the increase in EC during urea hydrolysis in a closed reactor to the concentration of ammonium species present (and concentration of urea remaining) in the reaction solution. By applying this function to data from continuous measurement of EC during urea hydrolysis, we obtain a profile of the concentration of the urea substrate with time, which is then used to determine the urease activity. The activity of commercially available urease extracted from jack beans was determined using this method and compared well to the activity determined using Nessler’s reagent, a commonly used colorimetric assay. This EC-based method is inexpensive and can be used for accurate determination of urease activity for a variety of applications. American Chemical Society 2023-04-06 /pmc/articles/PMC10116633/ /pubmed/37091411 http://dx.doi.org/10.1021/acsomega.2c08152 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Krishnan, Vinay Khodadadi Tirkolaei, Hamed Kavazanjian, Edward An Improved Method for Determining Urease Activity from Electrical Conductivity Measurements |
title | An Improved Method
for Determining Urease Activity
from Electrical Conductivity Measurements |
title_full | An Improved Method
for Determining Urease Activity
from Electrical Conductivity Measurements |
title_fullStr | An Improved Method
for Determining Urease Activity
from Electrical Conductivity Measurements |
title_full_unstemmed | An Improved Method
for Determining Urease Activity
from Electrical Conductivity Measurements |
title_short | An Improved Method
for Determining Urease Activity
from Electrical Conductivity Measurements |
title_sort | improved method
for determining urease activity
from electrical conductivity measurements |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10116633/ https://www.ncbi.nlm.nih.gov/pubmed/37091411 http://dx.doi.org/10.1021/acsomega.2c08152 |
work_keys_str_mv | AT krishnanvinay animprovedmethodfordeterminingureaseactivityfromelectricalconductivitymeasurements AT khodadaditirkolaeihamed animprovedmethodfordeterminingureaseactivityfromelectricalconductivitymeasurements AT kavazanjianedward animprovedmethodfordeterminingureaseactivityfromelectricalconductivitymeasurements AT krishnanvinay improvedmethodfordeterminingureaseactivityfromelectricalconductivitymeasurements AT khodadaditirkolaeihamed improvedmethodfordeterminingureaseactivityfromelectricalconductivitymeasurements AT kavazanjianedward improvedmethodfordeterminingureaseactivityfromelectricalconductivitymeasurements |