Cargando…

Can carotid artery Doppler variations induced by the end-expiratory occlusion maneuver predict fluid responsiveness in septic shock patients?

BACKGROUND: An increase in cardiac index (CI) during an end-expiratory occlusion test (EEOt) predicts fluid responsiveness in ventilated patients. However, if CI monitoring is unavailable or the echocardiographic window is difficult, using the carotid Doppler (CD) could be a feasible alternative to...

Descripción completa

Detalles Bibliográficos
Autores principales: D’Arrigo, Sonia, Dell’Anna, Antonio Maria, Sandroni, Claudio, Messina, Antonio, Cacciola, Sofia, Pacini, Chiara, Antonelli, Massimo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10116770/
https://www.ncbi.nlm.nih.gov/pubmed/37076861
http://dx.doi.org/10.1186/s13054-023-04422-9
_version_ 1785028496408444928
author D’Arrigo, Sonia
Dell’Anna, Antonio Maria
Sandroni, Claudio
Messina, Antonio
Cacciola, Sofia
Pacini, Chiara
Antonelli, Massimo
author_facet D’Arrigo, Sonia
Dell’Anna, Antonio Maria
Sandroni, Claudio
Messina, Antonio
Cacciola, Sofia
Pacini, Chiara
Antonelli, Massimo
author_sort D’Arrigo, Sonia
collection PubMed
description BACKGROUND: An increase in cardiac index (CI) during an end-expiratory occlusion test (EEOt) predicts fluid responsiveness in ventilated patients. However, if CI monitoring is unavailable or the echocardiographic window is difficult, using the carotid Doppler (CD) could be a feasible alternative to track CI changes. This study investigates whether changes in CD peak velocity (CDPV) and corrected flow time (cFT) during an EEOt were correlated with CI changes and if CDPV and cFT changes predicted fluid responsiveness in patients with septic shock. METHODS: Prospective, single-center study in adults with hemodynamic instability. The CDPV and cFT on carotid artery Doppler and hemodynamic variables from the pulse contour analysis EV1000™ were recorded at baseline, during a 20-s EEOt, and after fluid challenge (500 mL). We defined responders as those who increased CI ≥ 15% after a fluid challenge. RESULTS: We performed 44 measurements in 18 mechanically ventilated patients with septic shock and without arrhythmias. The fluid responsiveness rate was 43.2%. The changes in CDPV were significantly correlated with changes in CI during EEOt (r = 0.51 [0.26–0.71]). A significant, albeit lower correlation, was found for cFT (r = 0.35 [0.1–0.58]). An increase in CI ≥ 5.35% during EEOt predicted fluid responsiveness with 78.9% sensitivity and 91.7% specificity, with an area under the ROC curve (AUROC) of 0.85. An increase in CDPV ≥ 10.5% during an EEOt predicted fluid responsiveness with 96.2% specificity and 53.0% sensitivity with an AUROC of 0.74. Sixty-one percent of CDPV measurements (from − 13.5 to 9.5 cm/s) fell within the gray zone. The cFT changes during EEOt did not accurately predict fluid responsiveness. CONCLUSIONS: In septic shock patients without arrhythmias, an increase in CDPV greater than 10.5% during a 20-s EEOt predicted fluid responsiveness with > 95% specificity. Carotid Doppler combined with EEOt may help optimize preload when invasive hemodynamic monitoring is unavailable. However, the 61% gray zone is a major limitation (retrospectively registered on Clinicaltrials.gov NCT04470856 on July 14, 2020). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13054-023-04422-9.
format Online
Article
Text
id pubmed-10116770
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-101167702023-04-21 Can carotid artery Doppler variations induced by the end-expiratory occlusion maneuver predict fluid responsiveness in septic shock patients? D’Arrigo, Sonia Dell’Anna, Antonio Maria Sandroni, Claudio Messina, Antonio Cacciola, Sofia Pacini, Chiara Antonelli, Massimo Crit Care Research BACKGROUND: An increase in cardiac index (CI) during an end-expiratory occlusion test (EEOt) predicts fluid responsiveness in ventilated patients. However, if CI monitoring is unavailable or the echocardiographic window is difficult, using the carotid Doppler (CD) could be a feasible alternative to track CI changes. This study investigates whether changes in CD peak velocity (CDPV) and corrected flow time (cFT) during an EEOt were correlated with CI changes and if CDPV and cFT changes predicted fluid responsiveness in patients with septic shock. METHODS: Prospective, single-center study in adults with hemodynamic instability. The CDPV and cFT on carotid artery Doppler and hemodynamic variables from the pulse contour analysis EV1000™ were recorded at baseline, during a 20-s EEOt, and after fluid challenge (500 mL). We defined responders as those who increased CI ≥ 15% after a fluid challenge. RESULTS: We performed 44 measurements in 18 mechanically ventilated patients with septic shock and without arrhythmias. The fluid responsiveness rate was 43.2%. The changes in CDPV were significantly correlated with changes in CI during EEOt (r = 0.51 [0.26–0.71]). A significant, albeit lower correlation, was found for cFT (r = 0.35 [0.1–0.58]). An increase in CI ≥ 5.35% during EEOt predicted fluid responsiveness with 78.9% sensitivity and 91.7% specificity, with an area under the ROC curve (AUROC) of 0.85. An increase in CDPV ≥ 10.5% during an EEOt predicted fluid responsiveness with 96.2% specificity and 53.0% sensitivity with an AUROC of 0.74. Sixty-one percent of CDPV measurements (from − 13.5 to 9.5 cm/s) fell within the gray zone. The cFT changes during EEOt did not accurately predict fluid responsiveness. CONCLUSIONS: In septic shock patients without arrhythmias, an increase in CDPV greater than 10.5% during a 20-s EEOt predicted fluid responsiveness with > 95% specificity. Carotid Doppler combined with EEOt may help optimize preload when invasive hemodynamic monitoring is unavailable. However, the 61% gray zone is a major limitation (retrospectively registered on Clinicaltrials.gov NCT04470856 on July 14, 2020). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13054-023-04422-9. BioMed Central 2023-04-19 /pmc/articles/PMC10116770/ /pubmed/37076861 http://dx.doi.org/10.1186/s13054-023-04422-9 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
D’Arrigo, Sonia
Dell’Anna, Antonio Maria
Sandroni, Claudio
Messina, Antonio
Cacciola, Sofia
Pacini, Chiara
Antonelli, Massimo
Can carotid artery Doppler variations induced by the end-expiratory occlusion maneuver predict fluid responsiveness in septic shock patients?
title Can carotid artery Doppler variations induced by the end-expiratory occlusion maneuver predict fluid responsiveness in septic shock patients?
title_full Can carotid artery Doppler variations induced by the end-expiratory occlusion maneuver predict fluid responsiveness in septic shock patients?
title_fullStr Can carotid artery Doppler variations induced by the end-expiratory occlusion maneuver predict fluid responsiveness in septic shock patients?
title_full_unstemmed Can carotid artery Doppler variations induced by the end-expiratory occlusion maneuver predict fluid responsiveness in septic shock patients?
title_short Can carotid artery Doppler variations induced by the end-expiratory occlusion maneuver predict fluid responsiveness in septic shock patients?
title_sort can carotid artery doppler variations induced by the end-expiratory occlusion maneuver predict fluid responsiveness in septic shock patients?
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10116770/
https://www.ncbi.nlm.nih.gov/pubmed/37076861
http://dx.doi.org/10.1186/s13054-023-04422-9
work_keys_str_mv AT darrigosonia cancarotidarterydopplervariationsinducedbytheendexpiratoryocclusionmaneuverpredictfluidresponsivenessinsepticshockpatients
AT dellannaantoniomaria cancarotidarterydopplervariationsinducedbytheendexpiratoryocclusionmaneuverpredictfluidresponsivenessinsepticshockpatients
AT sandroniclaudio cancarotidarterydopplervariationsinducedbytheendexpiratoryocclusionmaneuverpredictfluidresponsivenessinsepticshockpatients
AT messinaantonio cancarotidarterydopplervariationsinducedbytheendexpiratoryocclusionmaneuverpredictfluidresponsivenessinsepticshockpatients
AT cacciolasofia cancarotidarterydopplervariationsinducedbytheendexpiratoryocclusionmaneuverpredictfluidresponsivenessinsepticshockpatients
AT pacinichiara cancarotidarterydopplervariationsinducedbytheendexpiratoryocclusionmaneuverpredictfluidresponsivenessinsepticshockpatients
AT antonellimassimo cancarotidarterydopplervariationsinducedbytheendexpiratoryocclusionmaneuverpredictfluidresponsivenessinsepticshockpatients