Cargando…

Accuracy of narrow‐band imaging for diagnosing malignant transformation of vocal cord leukoplakia: A systematic review and meta‐analysis

OBJECTIVE: To explore whether narrow‐band imaging (NBI) endoscopy is accurate in the diagnosis of malignant transformation of vocal cord leukoplakia. METHODS: The PubMed, Embase, Cochrane Library and Web of Science databases were searched to collect data on studies reporting the use of NBI endoscopy...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Jingyu, Li, Zhuojun, Wu, Ting, Chen, Xiumei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10116981/
https://www.ncbi.nlm.nih.gov/pubmed/37090880
http://dx.doi.org/10.1002/lio2.1049
_version_ 1785028536000577536
author Chen, Jingyu
Li, Zhuojun
Wu, Ting
Chen, Xiumei
author_facet Chen, Jingyu
Li, Zhuojun
Wu, Ting
Chen, Xiumei
author_sort Chen, Jingyu
collection PubMed
description OBJECTIVE: To explore whether narrow‐band imaging (NBI) endoscopy is accurate in the diagnosis of malignant transformation of vocal cord leukoplakia. METHODS: The PubMed, Embase, Cochrane Library and Web of Science databases were searched to collect data on studies reporting the use of NBI endoscopy as a diagnostic test for diagnosing vocal cord leukoplakia from January 2015 to December 2021. Study design, analysis method, and extraction results were performed according to the PRISMA guidelines. The sensitivity, specificity, pooled positive likelihood ratio (PLR), negative likelihood ratio (NLR) and area under the curve (AUC) were used to summarize the performance metrics of the meta‐analysis. Risk of bias data and the quality of the included studies was evaluated according to the Quality Assessment of Diagnostic Accuracy Studies‐2 tool (QUADAS‐2). RESULTS: Nine studies were finally included in the analysis. The results of the meta‐analysis showed that the pooled sensitivity and specificity of NBI endoscopy for diagnosing leukoplakia lesions were 0.76 (95% CI: 0.72–0.8) and 0.93 (95% CI: 0.91–0.95), respectively. The PLR and NLR were 10.09 (95% CI: 6.53–15.59) and 0.22 (95% CI: 0.13–0.38), respectively. The comprehensive diagnostic odds ratio (DOR) was 54.96 (95% CI: 24.32–124.17), and the area under the curve was 0.9584. The eight articles had a low risk of bias risk and one article was unclear. CONCLUSION: NBI likely has good accuracy for diagnosing malignant transformation of vocal cord leukoplakia. However, multicenter studies and large samples are still needed.
format Online
Article
Text
id pubmed-10116981
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-101169812023-04-21 Accuracy of narrow‐band imaging for diagnosing malignant transformation of vocal cord leukoplakia: A systematic review and meta‐analysis Chen, Jingyu Li, Zhuojun Wu, Ting Chen, Xiumei Laryngoscope Investig Otolaryngol Laryngology, Speech and Language Science OBJECTIVE: To explore whether narrow‐band imaging (NBI) endoscopy is accurate in the diagnosis of malignant transformation of vocal cord leukoplakia. METHODS: The PubMed, Embase, Cochrane Library and Web of Science databases were searched to collect data on studies reporting the use of NBI endoscopy as a diagnostic test for diagnosing vocal cord leukoplakia from January 2015 to December 2021. Study design, analysis method, and extraction results were performed according to the PRISMA guidelines. The sensitivity, specificity, pooled positive likelihood ratio (PLR), negative likelihood ratio (NLR) and area under the curve (AUC) were used to summarize the performance metrics of the meta‐analysis. Risk of bias data and the quality of the included studies was evaluated according to the Quality Assessment of Diagnostic Accuracy Studies‐2 tool (QUADAS‐2). RESULTS: Nine studies were finally included in the analysis. The results of the meta‐analysis showed that the pooled sensitivity and specificity of NBI endoscopy for diagnosing leukoplakia lesions were 0.76 (95% CI: 0.72–0.8) and 0.93 (95% CI: 0.91–0.95), respectively. The PLR and NLR were 10.09 (95% CI: 6.53–15.59) and 0.22 (95% CI: 0.13–0.38), respectively. The comprehensive diagnostic odds ratio (DOR) was 54.96 (95% CI: 24.32–124.17), and the area under the curve was 0.9584. The eight articles had a low risk of bias risk and one article was unclear. CONCLUSION: NBI likely has good accuracy for diagnosing malignant transformation of vocal cord leukoplakia. However, multicenter studies and large samples are still needed. John Wiley & Sons, Inc. 2023-03-29 /pmc/articles/PMC10116981/ /pubmed/37090880 http://dx.doi.org/10.1002/lio2.1049 Text en © 2023 The Authors. Laryngoscope Investigative Otolaryngology published by Wiley Periodicals LLC on behalf of The Triological Society. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Laryngology, Speech and Language Science
Chen, Jingyu
Li, Zhuojun
Wu, Ting
Chen, Xiumei
Accuracy of narrow‐band imaging for diagnosing malignant transformation of vocal cord leukoplakia: A systematic review and meta‐analysis
title Accuracy of narrow‐band imaging for diagnosing malignant transformation of vocal cord leukoplakia: A systematic review and meta‐analysis
title_full Accuracy of narrow‐band imaging for diagnosing malignant transformation of vocal cord leukoplakia: A systematic review and meta‐analysis
title_fullStr Accuracy of narrow‐band imaging for diagnosing malignant transformation of vocal cord leukoplakia: A systematic review and meta‐analysis
title_full_unstemmed Accuracy of narrow‐band imaging for diagnosing malignant transformation of vocal cord leukoplakia: A systematic review and meta‐analysis
title_short Accuracy of narrow‐band imaging for diagnosing malignant transformation of vocal cord leukoplakia: A systematic review and meta‐analysis
title_sort accuracy of narrow‐band imaging for diagnosing malignant transformation of vocal cord leukoplakia: a systematic review and meta‐analysis
topic Laryngology, Speech and Language Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10116981/
https://www.ncbi.nlm.nih.gov/pubmed/37090880
http://dx.doi.org/10.1002/lio2.1049
work_keys_str_mv AT chenjingyu accuracyofnarrowbandimagingfordiagnosingmalignanttransformationofvocalcordleukoplakiaasystematicreviewandmetaanalysis
AT lizhuojun accuracyofnarrowbandimagingfordiagnosingmalignanttransformationofvocalcordleukoplakiaasystematicreviewandmetaanalysis
AT wuting accuracyofnarrowbandimagingfordiagnosingmalignanttransformationofvocalcordleukoplakiaasystematicreviewandmetaanalysis
AT chenxiumei accuracyofnarrowbandimagingfordiagnosingmalignanttransformationofvocalcordleukoplakiaasystematicreviewandmetaanalysis