Cargando…

Development and Validation of Two Optimized Multiplexed Serologic Assays for the 9-Valent Human Papillomavirus Vaccine Types

Two multiplex immunoassays are routinely used to assess antibody responses in clinical trials of the 9-valent human papillomavirus (9vHPV) vaccine. The HPV6/11/16/18/31/33/45/52/58 competitive Luminex immunoassay (HPV-9 cLIA) and HPV6/11/16/18/31/33/45/52/58 total immunoglobulin G Luminex immunoassa...

Descripción completa

Detalles Bibliográficos
Autores principales: Nolan, Katrina M., Seaton, Brent, Antonello, Joseph, Zhang, Yuhua, Cook, Lauren, Delfino, Krystyn, Rubinstein, Leonard J., Cheon, Kyeongmi, Group, Thomas, Luxembourg, Alain, Dubey, Sheri
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society for Microbiology 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10117101/
https://www.ncbi.nlm.nih.gov/pubmed/36926984
http://dx.doi.org/10.1128/msphere.00962-21
_version_ 1785028558051082240
author Nolan, Katrina M.
Seaton, Brent
Antonello, Joseph
Zhang, Yuhua
Cook, Lauren
Delfino, Krystyn
Rubinstein, Leonard J.
Cheon, Kyeongmi
Group, Thomas
Luxembourg, Alain
Dubey, Sheri
author_facet Nolan, Katrina M.
Seaton, Brent
Antonello, Joseph
Zhang, Yuhua
Cook, Lauren
Delfino, Krystyn
Rubinstein, Leonard J.
Cheon, Kyeongmi
Group, Thomas
Luxembourg, Alain
Dubey, Sheri
author_sort Nolan, Katrina M.
collection PubMed
description Two multiplex immunoassays are routinely used to assess antibody responses in clinical trials of the 9-valent human papillomavirus (9vHPV) vaccine. The HPV6/11/16/18/31/33/45/52/58 competitive Luminex immunoassay (HPV-9 cLIA) and HPV6/11/16/18/31/33/45/52/58 total immunoglobulin G Luminex immunoassay are used for measurements of immunogenicity. Following their initial validation in 2010, both assays were redeveloped, and several parameters were optimized, including the coating concentration of virus-like particles, type of Luminex microspheres, serum sample and reference standard diluent, reference standard starting dilution and titration series, and vendor and concentration of the phycoerythrin-labeled antibodies. Validation studies evaluated the assay performance parameters, including the intra-assay precision (repeatability), intermediate precision, linearity, relative accuracy, and limits of quantitation. In addition, since maintaining a link to the original assays that were used in trials supporting vaccine licensure is critical, the assays were formally bridged to the previous assay versions by using individual patient sera from a 9vHPV vaccine clinical trial (n = 150 day 1 [prevaccination] samples; n = 100 month 7 [1 month post-last vaccine dose] and n = 100 month 36 [30 months post-last vaccine dose; antibody persistence] samples). The results of the validation studies indicate that both optimized assays are accurate, specific, and precise over their respective quantifiable ranges. There was a strong linear association between the new and previous versions of both assays. Assay serostatus cutoffs for the redeveloped assays were established based on the bridging studies and, for the HPV-9 cLIA, further refined, based on additional data from HPV vaccine clinical studies so as to align the seropositivity rates between assay versions. IMPORTANCE Assay modernization is a key aspect of vaccine life cycle management. Thus, new, reoptimized versions of two 9vHPV immunoassays have been developed and validated for use in ongoing and future HPV vaccine clinical trials. These assays are suitable for use in high-throughput testing for HPV antibodies in serum samples. Bridging to previous versions of the assays allows for the continuous monitoring of immune responses across assay versions, including in immunogenicity studies that involve new populations as well as long-term follow-up studies.
format Online
Article
Text
id pubmed-10117101
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher American Society for Microbiology
record_format MEDLINE/PubMed
spelling pubmed-101171012023-04-21 Development and Validation of Two Optimized Multiplexed Serologic Assays for the 9-Valent Human Papillomavirus Vaccine Types Nolan, Katrina M. Seaton, Brent Antonello, Joseph Zhang, Yuhua Cook, Lauren Delfino, Krystyn Rubinstein, Leonard J. Cheon, Kyeongmi Group, Thomas Luxembourg, Alain Dubey, Sheri mSphere Research Article Two multiplex immunoassays are routinely used to assess antibody responses in clinical trials of the 9-valent human papillomavirus (9vHPV) vaccine. The HPV6/11/16/18/31/33/45/52/58 competitive Luminex immunoassay (HPV-9 cLIA) and HPV6/11/16/18/31/33/45/52/58 total immunoglobulin G Luminex immunoassay are used for measurements of immunogenicity. Following their initial validation in 2010, both assays were redeveloped, and several parameters were optimized, including the coating concentration of virus-like particles, type of Luminex microspheres, serum sample and reference standard diluent, reference standard starting dilution and titration series, and vendor and concentration of the phycoerythrin-labeled antibodies. Validation studies evaluated the assay performance parameters, including the intra-assay precision (repeatability), intermediate precision, linearity, relative accuracy, and limits of quantitation. In addition, since maintaining a link to the original assays that were used in trials supporting vaccine licensure is critical, the assays were formally bridged to the previous assay versions by using individual patient sera from a 9vHPV vaccine clinical trial (n = 150 day 1 [prevaccination] samples; n = 100 month 7 [1 month post-last vaccine dose] and n = 100 month 36 [30 months post-last vaccine dose; antibody persistence] samples). The results of the validation studies indicate that both optimized assays are accurate, specific, and precise over their respective quantifiable ranges. There was a strong linear association between the new and previous versions of both assays. Assay serostatus cutoffs for the redeveloped assays were established based on the bridging studies and, for the HPV-9 cLIA, further refined, based on additional data from HPV vaccine clinical studies so as to align the seropositivity rates between assay versions. IMPORTANCE Assay modernization is a key aspect of vaccine life cycle management. Thus, new, reoptimized versions of two 9vHPV immunoassays have been developed and validated for use in ongoing and future HPV vaccine clinical trials. These assays are suitable for use in high-throughput testing for HPV antibodies in serum samples. Bridging to previous versions of the assays allows for the continuous monitoring of immune responses across assay versions, including in immunogenicity studies that involve new populations as well as long-term follow-up studies. American Society for Microbiology 2023-03-16 /pmc/articles/PMC10117101/ /pubmed/36926984 http://dx.doi.org/10.1128/msphere.00962-21 Text en Copyright © 2023 Nolan et al. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Article
Nolan, Katrina M.
Seaton, Brent
Antonello, Joseph
Zhang, Yuhua
Cook, Lauren
Delfino, Krystyn
Rubinstein, Leonard J.
Cheon, Kyeongmi
Group, Thomas
Luxembourg, Alain
Dubey, Sheri
Development and Validation of Two Optimized Multiplexed Serologic Assays for the 9-Valent Human Papillomavirus Vaccine Types
title Development and Validation of Two Optimized Multiplexed Serologic Assays for the 9-Valent Human Papillomavirus Vaccine Types
title_full Development and Validation of Two Optimized Multiplexed Serologic Assays for the 9-Valent Human Papillomavirus Vaccine Types
title_fullStr Development and Validation of Two Optimized Multiplexed Serologic Assays for the 9-Valent Human Papillomavirus Vaccine Types
title_full_unstemmed Development and Validation of Two Optimized Multiplexed Serologic Assays for the 9-Valent Human Papillomavirus Vaccine Types
title_short Development and Validation of Two Optimized Multiplexed Serologic Assays for the 9-Valent Human Papillomavirus Vaccine Types
title_sort development and validation of two optimized multiplexed serologic assays for the 9-valent human papillomavirus vaccine types
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10117101/
https://www.ncbi.nlm.nih.gov/pubmed/36926984
http://dx.doi.org/10.1128/msphere.00962-21
work_keys_str_mv AT nolankatrinam developmentandvalidationoftwooptimizedmultiplexedserologicassaysforthe9valenthumanpapillomavirusvaccinetypes
AT seatonbrent developmentandvalidationoftwooptimizedmultiplexedserologicassaysforthe9valenthumanpapillomavirusvaccinetypes
AT antonellojoseph developmentandvalidationoftwooptimizedmultiplexedserologicassaysforthe9valenthumanpapillomavirusvaccinetypes
AT zhangyuhua developmentandvalidationoftwooptimizedmultiplexedserologicassaysforthe9valenthumanpapillomavirusvaccinetypes
AT cooklauren developmentandvalidationoftwooptimizedmultiplexedserologicassaysforthe9valenthumanpapillomavirusvaccinetypes
AT delfinokrystyn developmentandvalidationoftwooptimizedmultiplexedserologicassaysforthe9valenthumanpapillomavirusvaccinetypes
AT rubinsteinleonardj developmentandvalidationoftwooptimizedmultiplexedserologicassaysforthe9valenthumanpapillomavirusvaccinetypes
AT cheonkyeongmi developmentandvalidationoftwooptimizedmultiplexedserologicassaysforthe9valenthumanpapillomavirusvaccinetypes
AT groupthomas developmentandvalidationoftwooptimizedmultiplexedserologicassaysforthe9valenthumanpapillomavirusvaccinetypes
AT luxembourgalain developmentandvalidationoftwooptimizedmultiplexedserologicassaysforthe9valenthumanpapillomavirusvaccinetypes
AT dubeysheri developmentandvalidationoftwooptimizedmultiplexedserologicassaysforthe9valenthumanpapillomavirusvaccinetypes