Cargando…
Voxel-based dosimetry predicting treatment response and related toxicity in HCC patients treated with resin-based Y90 radioembolization: a prospective, single-arm study
BACKGROUND: There is an increasing body of evidence indicating Y90 dose thresholds for tumor response and treatment-related toxicity. These thresholds are poorly studied in resin Y90, particularly in hepatocellular carcinoma (HCC). PURPOSE: To evaluate the efficacy of prospective voxel-based dosimet...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10119065/ https://www.ncbi.nlm.nih.gov/pubmed/36650357 http://dx.doi.org/10.1007/s00259-023-06111-9 |
_version_ | 1785028942205288448 |
---|---|
author | Kokabi, Nima Arndt-Webster, Linzi Chen, Bernard Brandon, David Sethi, Ila Davarpanahfakhr, Amir Galt, James Elsayed, Mohammad Bercu, Zachary Cristescu, Mircea Kappadath, S. Cheenu Schuster, David M. |
author_facet | Kokabi, Nima Arndt-Webster, Linzi Chen, Bernard Brandon, David Sethi, Ila Davarpanahfakhr, Amir Galt, James Elsayed, Mohammad Bercu, Zachary Cristescu, Mircea Kappadath, S. Cheenu Schuster, David M. |
author_sort | Kokabi, Nima |
collection | PubMed |
description | BACKGROUND: There is an increasing body of evidence indicating Y90 dose thresholds for tumor response and treatment-related toxicity. These thresholds are poorly studied in resin Y90, particularly in hepatocellular carcinoma (HCC). PURPOSE: To evaluate the efficacy of prospective voxel-based dosimetry for predicting treatment response and adverse events (AEs) in patients with HCC undergoing resin-based Y90 radioembolization. MATERIALS AND METHODS: This correlative study was based on a prospective single-arm clinical trial (NCT04172714), which evaluated the efficacy of low/scout (555 MBq) activity of resin-based Y90 for treatment planning. Partition model was used with goal of tumor dose (TD) > 200 Gy and non-tumoral liver dose (NTLD) < 70 Gy for non-segmental therapies. Single compartment dose of 200 Gy was used for segmentectomies. Prescribed Y90 activity minus scout activity was administered for therapeutic Y90 followed by Y90-PET/CT. Sureplan® (MIM Software, Cleveland, OH) was used for dosimetry analysis. Treatment response was evaluated at 3 and 6 months. Receiver operating characteristic curve determined TD response threshold for objective response (OR) and complete response (CR) as well as non-tumor liver dose (NTLD) threshold that predicted AEs. RESULTS: N = 30 patients were treated with 33 tumors (19 segmental and 14 non-segmental). One patient died before the first imaging, and clinical follow-up was excluded from this analysis. Overall, 26 (81%) of the tumors had an OR and 23 (72%) had a CR. A mean TD of 253 Gy predicted an OR with 92% sensitivity and 83% specificity (area under the curve (AUC = 0.929, p < 0.001). A mean TD of 337 Gy predicted a CR with 83% sensitivity and 89% specificity (AUC = 0.845, p < 0.001). A mean NTLD of 81 and 87 Gy predicted grade 3 AEs with 100% sensitivity and 100% specificity in the non-segmental cohort at 3- and 6-month post Y90, respectively. CONCLUSION: In patients with HCC undergoing resin-based Y90, there are dose response and dose toxicity thresholds directly affecting outcomes. Clinical trial number: NCT04172714. |
format | Online Article Text |
id | pubmed-10119065 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-101190652023-04-22 Voxel-based dosimetry predicting treatment response and related toxicity in HCC patients treated with resin-based Y90 radioembolization: a prospective, single-arm study Kokabi, Nima Arndt-Webster, Linzi Chen, Bernard Brandon, David Sethi, Ila Davarpanahfakhr, Amir Galt, James Elsayed, Mohammad Bercu, Zachary Cristescu, Mircea Kappadath, S. Cheenu Schuster, David M. Eur J Nucl Med Mol Imaging Original Article BACKGROUND: There is an increasing body of evidence indicating Y90 dose thresholds for tumor response and treatment-related toxicity. These thresholds are poorly studied in resin Y90, particularly in hepatocellular carcinoma (HCC). PURPOSE: To evaluate the efficacy of prospective voxel-based dosimetry for predicting treatment response and adverse events (AEs) in patients with HCC undergoing resin-based Y90 radioembolization. MATERIALS AND METHODS: This correlative study was based on a prospective single-arm clinical trial (NCT04172714), which evaluated the efficacy of low/scout (555 MBq) activity of resin-based Y90 for treatment planning. Partition model was used with goal of tumor dose (TD) > 200 Gy and non-tumoral liver dose (NTLD) < 70 Gy for non-segmental therapies. Single compartment dose of 200 Gy was used for segmentectomies. Prescribed Y90 activity minus scout activity was administered for therapeutic Y90 followed by Y90-PET/CT. Sureplan® (MIM Software, Cleveland, OH) was used for dosimetry analysis. Treatment response was evaluated at 3 and 6 months. Receiver operating characteristic curve determined TD response threshold for objective response (OR) and complete response (CR) as well as non-tumor liver dose (NTLD) threshold that predicted AEs. RESULTS: N = 30 patients were treated with 33 tumors (19 segmental and 14 non-segmental). One patient died before the first imaging, and clinical follow-up was excluded from this analysis. Overall, 26 (81%) of the tumors had an OR and 23 (72%) had a CR. A mean TD of 253 Gy predicted an OR with 92% sensitivity and 83% specificity (area under the curve (AUC = 0.929, p < 0.001). A mean TD of 337 Gy predicted a CR with 83% sensitivity and 89% specificity (AUC = 0.845, p < 0.001). A mean NTLD of 81 and 87 Gy predicted grade 3 AEs with 100% sensitivity and 100% specificity in the non-segmental cohort at 3- and 6-month post Y90, respectively. CONCLUSION: In patients with HCC undergoing resin-based Y90, there are dose response and dose toxicity thresholds directly affecting outcomes. Clinical trial number: NCT04172714. Springer Berlin Heidelberg 2023-01-18 2023 /pmc/articles/PMC10119065/ /pubmed/36650357 http://dx.doi.org/10.1007/s00259-023-06111-9 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Kokabi, Nima Arndt-Webster, Linzi Chen, Bernard Brandon, David Sethi, Ila Davarpanahfakhr, Amir Galt, James Elsayed, Mohammad Bercu, Zachary Cristescu, Mircea Kappadath, S. Cheenu Schuster, David M. Voxel-based dosimetry predicting treatment response and related toxicity in HCC patients treated with resin-based Y90 radioembolization: a prospective, single-arm study |
title | Voxel-based dosimetry predicting treatment response and related toxicity in HCC patients treated with resin-based Y90 radioembolization: a prospective, single-arm study |
title_full | Voxel-based dosimetry predicting treatment response and related toxicity in HCC patients treated with resin-based Y90 radioembolization: a prospective, single-arm study |
title_fullStr | Voxel-based dosimetry predicting treatment response and related toxicity in HCC patients treated with resin-based Y90 radioembolization: a prospective, single-arm study |
title_full_unstemmed | Voxel-based dosimetry predicting treatment response and related toxicity in HCC patients treated with resin-based Y90 radioembolization: a prospective, single-arm study |
title_short | Voxel-based dosimetry predicting treatment response and related toxicity in HCC patients treated with resin-based Y90 radioembolization: a prospective, single-arm study |
title_sort | voxel-based dosimetry predicting treatment response and related toxicity in hcc patients treated with resin-based y90 radioembolization: a prospective, single-arm study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10119065/ https://www.ncbi.nlm.nih.gov/pubmed/36650357 http://dx.doi.org/10.1007/s00259-023-06111-9 |
work_keys_str_mv | AT kokabinima voxelbaseddosimetrypredictingtreatmentresponseandrelatedtoxicityinhccpatientstreatedwithresinbasedy90radioembolizationaprospectivesinglearmstudy AT arndtwebsterlinzi voxelbaseddosimetrypredictingtreatmentresponseandrelatedtoxicityinhccpatientstreatedwithresinbasedy90radioembolizationaprospectivesinglearmstudy AT chenbernard voxelbaseddosimetrypredictingtreatmentresponseandrelatedtoxicityinhccpatientstreatedwithresinbasedy90radioembolizationaprospectivesinglearmstudy AT brandondavid voxelbaseddosimetrypredictingtreatmentresponseandrelatedtoxicityinhccpatientstreatedwithresinbasedy90radioembolizationaprospectivesinglearmstudy AT sethiila voxelbaseddosimetrypredictingtreatmentresponseandrelatedtoxicityinhccpatientstreatedwithresinbasedy90radioembolizationaprospectivesinglearmstudy AT davarpanahfakhramir voxelbaseddosimetrypredictingtreatmentresponseandrelatedtoxicityinhccpatientstreatedwithresinbasedy90radioembolizationaprospectivesinglearmstudy AT galtjames voxelbaseddosimetrypredictingtreatmentresponseandrelatedtoxicityinhccpatientstreatedwithresinbasedy90radioembolizationaprospectivesinglearmstudy AT elsayedmohammad voxelbaseddosimetrypredictingtreatmentresponseandrelatedtoxicityinhccpatientstreatedwithresinbasedy90radioembolizationaprospectivesinglearmstudy AT bercuzachary voxelbaseddosimetrypredictingtreatmentresponseandrelatedtoxicityinhccpatientstreatedwithresinbasedy90radioembolizationaprospectivesinglearmstudy AT cristescumircea voxelbaseddosimetrypredictingtreatmentresponseandrelatedtoxicityinhccpatientstreatedwithresinbasedy90radioembolizationaprospectivesinglearmstudy AT kappadathscheenu voxelbaseddosimetrypredictingtreatmentresponseandrelatedtoxicityinhccpatientstreatedwithresinbasedy90radioembolizationaprospectivesinglearmstudy AT schusterdavidm voxelbaseddosimetrypredictingtreatmentresponseandrelatedtoxicityinhccpatientstreatedwithresinbasedy90radioembolizationaprospectivesinglearmstudy |