Cargando…

Evaluation and Comparison of Stress in Divergent and Convergent Collar Designs of Implants With Different Bone Densities: A Finite Element Study

Background: The failure and the success rate of an implant depends on biomechanical factors, esthetics and painless sterile implant surgery conditions, out of which stresses applied to the bone and its surrounding, bone-implant interface, material characteristics of the implant used and the strength...

Descripción completa

Detalles Bibliográficos
Autores principales: Panmei, Gracy, Kumar, Arunoday, Basak, Suchetana, Anal, Seltun S, Nongthombam, Rajesh, Mall, Braj B
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10121484/
https://www.ncbi.nlm.nih.gov/pubmed/37095819
http://dx.doi.org/10.7759/cureus.36550
_version_ 1785029379758227456
author Panmei, Gracy
Kumar, Arunoday
Basak, Suchetana
Anal, Seltun S
Nongthombam, Rajesh
Mall, Braj B
author_facet Panmei, Gracy
Kumar, Arunoday
Basak, Suchetana
Anal, Seltun S
Nongthombam, Rajesh
Mall, Braj B
author_sort Panmei, Gracy
collection PubMed
description Background: The failure and the success rate of an implant depends on biomechanical factors, esthetics and painless sterile implant surgery conditions, out of which stresses applied to the bone and its surrounding, bone-implant interface, material characteristics of the implant used and the strength of the bone and its surrounding are the important factors. This study aimed to evaluate the stress distribution of divergent collar design (DCD) and convergent collar design (CCD) implants placing them in four different densities of the bone (D1, D2, D3 and D4). The evaluation of the stress distribution of DCD and CCD was performed using the 3D finite element method (FEM), by placing them in four different bone densities. In addition to this, a comparison of the effect of DCD and CCD in terms of stress distribution in the bone was also done. Materials and methods: The software used to process the geometric characteristics of the missing first molar in the mandibular section were Ansys, version 19.2, CATIA, version 5, and Solidworks (Dassault Systèmes). Using these software, three models were designed and successfully restored using an all-ceramic crown implant. The first model was a geometric model of the first molar mandibular bone section, the second model was a cylindrical implant (4x10 mm) with a DCD and CCD, and the third model had titanium alloy (Ti-6Al-4V) properties incorporated into the implant. Results: The D1 bone model showed the lowest stress concentration compared to D2, D3, D4. The DCD showed the lower stress and strain concentrations as compared to the CCD in the contiguous crestal bone in all the densities of the bone in both vertical and lateral or oblique loadings. The DCD with the D1 bone showed the least stress concentration around the crestal bone region. The results of this study also showed that the maximum von Mises stress was observed in the crestal region or the neck of the implant for both the convergent and divergent collar implant designs in all the four densities of the bone. Conclusion: Before a patient trial of a new implant design or a new implant material, finite element analysis (FEA) gives us a clear picture of what will be the patient bone response when an implant will be placed and loaded. FEA also gives us an opportunity to test a new implant material without putting a patient at risk. In this study, four different types of bone were incorporated with two different implant collar designs. Each implant assembly was subjected to vertical as well as oblique forces. The response of each bone type for the titanium alloy implant was recorded. A color-coded response for the magnitude and the location of the maximum stress received by the bone was observed. Maximum stresses were seen in the crestal region. As this is a computer-based model, dynamic loading was not possible. This study provided us with the possible outcome in patients under a static load. Further studies can be conducted in vivo to record dynamic loading responses as well as long-time loading responses.
format Online
Article
Text
id pubmed-10121484
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-101214842023-04-23 Evaluation and Comparison of Stress in Divergent and Convergent Collar Designs of Implants With Different Bone Densities: A Finite Element Study Panmei, Gracy Kumar, Arunoday Basak, Suchetana Anal, Seltun S Nongthombam, Rajesh Mall, Braj B Cureus Dentistry Background: The failure and the success rate of an implant depends on biomechanical factors, esthetics and painless sterile implant surgery conditions, out of which stresses applied to the bone and its surrounding, bone-implant interface, material characteristics of the implant used and the strength of the bone and its surrounding are the important factors. This study aimed to evaluate the stress distribution of divergent collar design (DCD) and convergent collar design (CCD) implants placing them in four different densities of the bone (D1, D2, D3 and D4). The evaluation of the stress distribution of DCD and CCD was performed using the 3D finite element method (FEM), by placing them in four different bone densities. In addition to this, a comparison of the effect of DCD and CCD in terms of stress distribution in the bone was also done. Materials and methods: The software used to process the geometric characteristics of the missing first molar in the mandibular section were Ansys, version 19.2, CATIA, version 5, and Solidworks (Dassault Systèmes). Using these software, three models were designed and successfully restored using an all-ceramic crown implant. The first model was a geometric model of the first molar mandibular bone section, the second model was a cylindrical implant (4x10 mm) with a DCD and CCD, and the third model had titanium alloy (Ti-6Al-4V) properties incorporated into the implant. Results: The D1 bone model showed the lowest stress concentration compared to D2, D3, D4. The DCD showed the lower stress and strain concentrations as compared to the CCD in the contiguous crestal bone in all the densities of the bone in both vertical and lateral or oblique loadings. The DCD with the D1 bone showed the least stress concentration around the crestal bone region. The results of this study also showed that the maximum von Mises stress was observed in the crestal region or the neck of the implant for both the convergent and divergent collar implant designs in all the four densities of the bone. Conclusion: Before a patient trial of a new implant design or a new implant material, finite element analysis (FEA) gives us a clear picture of what will be the patient bone response when an implant will be placed and loaded. FEA also gives us an opportunity to test a new implant material without putting a patient at risk. In this study, four different types of bone were incorporated with two different implant collar designs. Each implant assembly was subjected to vertical as well as oblique forces. The response of each bone type for the titanium alloy implant was recorded. A color-coded response for the magnitude and the location of the maximum stress received by the bone was observed. Maximum stresses were seen in the crestal region. As this is a computer-based model, dynamic loading was not possible. This study provided us with the possible outcome in patients under a static load. Further studies can be conducted in vivo to record dynamic loading responses as well as long-time loading responses. Cureus 2023-03-22 /pmc/articles/PMC10121484/ /pubmed/37095819 http://dx.doi.org/10.7759/cureus.36550 Text en Copyright © 2023, Panmei et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Dentistry
Panmei, Gracy
Kumar, Arunoday
Basak, Suchetana
Anal, Seltun S
Nongthombam, Rajesh
Mall, Braj B
Evaluation and Comparison of Stress in Divergent and Convergent Collar Designs of Implants With Different Bone Densities: A Finite Element Study
title Evaluation and Comparison of Stress in Divergent and Convergent Collar Designs of Implants With Different Bone Densities: A Finite Element Study
title_full Evaluation and Comparison of Stress in Divergent and Convergent Collar Designs of Implants With Different Bone Densities: A Finite Element Study
title_fullStr Evaluation and Comparison of Stress in Divergent and Convergent Collar Designs of Implants With Different Bone Densities: A Finite Element Study
title_full_unstemmed Evaluation and Comparison of Stress in Divergent and Convergent Collar Designs of Implants With Different Bone Densities: A Finite Element Study
title_short Evaluation and Comparison of Stress in Divergent and Convergent Collar Designs of Implants With Different Bone Densities: A Finite Element Study
title_sort evaluation and comparison of stress in divergent and convergent collar designs of implants with different bone densities: a finite element study
topic Dentistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10121484/
https://www.ncbi.nlm.nih.gov/pubmed/37095819
http://dx.doi.org/10.7759/cureus.36550
work_keys_str_mv AT panmeigracy evaluationandcomparisonofstressindivergentandconvergentcollardesignsofimplantswithdifferentbonedensitiesafiniteelementstudy
AT kumararunoday evaluationandcomparisonofstressindivergentandconvergentcollardesignsofimplantswithdifferentbonedensitiesafiniteelementstudy
AT basaksuchetana evaluationandcomparisonofstressindivergentandconvergentcollardesignsofimplantswithdifferentbonedensitiesafiniteelementstudy
AT analseltuns evaluationandcomparisonofstressindivergentandconvergentcollardesignsofimplantswithdifferentbonedensitiesafiniteelementstudy
AT nongthombamrajesh evaluationandcomparisonofstressindivergentandconvergentcollardesignsofimplantswithdifferentbonedensitiesafiniteelementstudy
AT mallbrajb evaluationandcomparisonofstressindivergentandconvergentcollardesignsofimplantswithdifferentbonedensitiesafiniteelementstudy