Cargando…

Urine as matrix for analysis of neurofilament light chain is not suitable to distinguish frontotemporal dementia from psychiatric diseases

The clinical overlap of frontotemporal dementia and primary psychiatric diseases hampers diagnostic distinction, leading to frequent misdiagnosis and diagnostic delay. Neurofilament light chain has shown great potential in CSF and blood for the distinction of frontotemporal dementia from primary psy...

Descripción completa

Detalles Bibliográficos
Autores principales: van Engelen, Marie-Paule E, Heijst, Hans, Willemse, Eline A J, Oudega, Mardien L, Vermunt, Lisa, Scheltens, Philip, Vijverberg, Everard G B, Pijnenburg, Yolande A L, Teunissen, Charlotte E
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10123396/
https://www.ncbi.nlm.nih.gov/pubmed/37101834
http://dx.doi.org/10.1093/braincomms/fcad120
_version_ 1785029658794786816
author van Engelen, Marie-Paule E
Heijst, Hans
Willemse, Eline A J
Oudega, Mardien L
Vermunt, Lisa
Scheltens, Philip
Vijverberg, Everard G B
Pijnenburg, Yolande A L
Teunissen, Charlotte E
author_facet van Engelen, Marie-Paule E
Heijst, Hans
Willemse, Eline A J
Oudega, Mardien L
Vermunt, Lisa
Scheltens, Philip
Vijverberg, Everard G B
Pijnenburg, Yolande A L
Teunissen, Charlotte E
author_sort van Engelen, Marie-Paule E
collection PubMed
description The clinical overlap of frontotemporal dementia and primary psychiatric diseases hampers diagnostic distinction, leading to frequent misdiagnosis and diagnostic delay. Neurofilament light chain has shown great potential in CSF and blood for the distinction of frontotemporal dementia from primary psychiatric diseases. Measurement of neurofilament light chain in urine would be even more patient-friendly. We aimed to test the performance of neurofilament light chain urine measurements for diagnostics in frontotemporal dementia and to assess their correlation with serum levels. Fifty-five subjects (n = 19 frontotemporal dementia, n = 19 primary psychiatric diseases and n = 17 controls) were included with available paired urine and serum samples. All subjects underwent standardized extensive diagnostic assessment. Samples were analysed with the ultrasensitive single molecule array neurofilament light chain assay. Neurofilament light chain group comparisons were performed adjusted for age, sex and geriatric depression scale. In the majority of the cohort, neurofilament light chain concentrations were not detectable in urine (n = 6 samples above lower limit of detection (0.038 pg/ml): n = 5 frontotemporal dementia, n = 1 primary psychiatric disease). The frequency of a detectable neurofilament light chain level in urine in the frontotemporal dementia group did not differ from psychiatric disorders (Fisher Exact-test P = 0.180). In the individuals with detectable urine neurofilament light chain values, there was no correlation between the urine and serum neurofilament light chain levels. As expected, serum neurofilament light chain levels were higher in frontotemporal dementia compared to primary psychiatric diseases and controls (P < 0.001), adjusted for age, sex and geriatric depression scale. Receiver operating characteristic curve analysis of serum neurofilament light chain of frontotemporal dementia versus primary psychiatric diseases showed an area under the curve of 0.978 95% confidence interval 0.941–1.000, P < 0.001. Urine is not suitable as a matrix for neurofilament light chain analysis and serum neurofilament light chain is still the most patient-friendly matrix for differentiation between frontotemporal dementia and primary psychiatric diseases.
format Online
Article
Text
id pubmed-10123396
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-101233962023-04-25 Urine as matrix for analysis of neurofilament light chain is not suitable to distinguish frontotemporal dementia from psychiatric diseases van Engelen, Marie-Paule E Heijst, Hans Willemse, Eline A J Oudega, Mardien L Vermunt, Lisa Scheltens, Philip Vijverberg, Everard G B Pijnenburg, Yolande A L Teunissen, Charlotte E Brain Commun Original Article The clinical overlap of frontotemporal dementia and primary psychiatric diseases hampers diagnostic distinction, leading to frequent misdiagnosis and diagnostic delay. Neurofilament light chain has shown great potential in CSF and blood for the distinction of frontotemporal dementia from primary psychiatric diseases. Measurement of neurofilament light chain in urine would be even more patient-friendly. We aimed to test the performance of neurofilament light chain urine measurements for diagnostics in frontotemporal dementia and to assess their correlation with serum levels. Fifty-five subjects (n = 19 frontotemporal dementia, n = 19 primary psychiatric diseases and n = 17 controls) were included with available paired urine and serum samples. All subjects underwent standardized extensive diagnostic assessment. Samples were analysed with the ultrasensitive single molecule array neurofilament light chain assay. Neurofilament light chain group comparisons were performed adjusted for age, sex and geriatric depression scale. In the majority of the cohort, neurofilament light chain concentrations were not detectable in urine (n = 6 samples above lower limit of detection (0.038 pg/ml): n = 5 frontotemporal dementia, n = 1 primary psychiatric disease). The frequency of a detectable neurofilament light chain level in urine in the frontotemporal dementia group did not differ from psychiatric disorders (Fisher Exact-test P = 0.180). In the individuals with detectable urine neurofilament light chain values, there was no correlation between the urine and serum neurofilament light chain levels. As expected, serum neurofilament light chain levels were higher in frontotemporal dementia compared to primary psychiatric diseases and controls (P < 0.001), adjusted for age, sex and geriatric depression scale. Receiver operating characteristic curve analysis of serum neurofilament light chain of frontotemporal dementia versus primary psychiatric diseases showed an area under the curve of 0.978 95% confidence interval 0.941–1.000, P < 0.001. Urine is not suitable as a matrix for neurofilament light chain analysis and serum neurofilament light chain is still the most patient-friendly matrix for differentiation between frontotemporal dementia and primary psychiatric diseases. Oxford University Press 2023-04-12 /pmc/articles/PMC10123396/ /pubmed/37101834 http://dx.doi.org/10.1093/braincomms/fcad120 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the Guarantors of Brain. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
van Engelen, Marie-Paule E
Heijst, Hans
Willemse, Eline A J
Oudega, Mardien L
Vermunt, Lisa
Scheltens, Philip
Vijverberg, Everard G B
Pijnenburg, Yolande A L
Teunissen, Charlotte E
Urine as matrix for analysis of neurofilament light chain is not suitable to distinguish frontotemporal dementia from psychiatric diseases
title Urine as matrix for analysis of neurofilament light chain is not suitable to distinguish frontotemporal dementia from psychiatric diseases
title_full Urine as matrix for analysis of neurofilament light chain is not suitable to distinguish frontotemporal dementia from psychiatric diseases
title_fullStr Urine as matrix for analysis of neurofilament light chain is not suitable to distinguish frontotemporal dementia from psychiatric diseases
title_full_unstemmed Urine as matrix for analysis of neurofilament light chain is not suitable to distinguish frontotemporal dementia from psychiatric diseases
title_short Urine as matrix for analysis of neurofilament light chain is not suitable to distinguish frontotemporal dementia from psychiatric diseases
title_sort urine as matrix for analysis of neurofilament light chain is not suitable to distinguish frontotemporal dementia from psychiatric diseases
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10123396/
https://www.ncbi.nlm.nih.gov/pubmed/37101834
http://dx.doi.org/10.1093/braincomms/fcad120
work_keys_str_mv AT vanengelenmariepaulee urineasmatrixforanalysisofneurofilamentlightchainisnotsuitabletodistinguishfrontotemporaldementiafrompsychiatricdiseases
AT heijsthans urineasmatrixforanalysisofneurofilamentlightchainisnotsuitabletodistinguishfrontotemporaldementiafrompsychiatricdiseases
AT willemseelineaj urineasmatrixforanalysisofneurofilamentlightchainisnotsuitabletodistinguishfrontotemporaldementiafrompsychiatricdiseases
AT oudegamardienl urineasmatrixforanalysisofneurofilamentlightchainisnotsuitabletodistinguishfrontotemporaldementiafrompsychiatricdiseases
AT vermuntlisa urineasmatrixforanalysisofneurofilamentlightchainisnotsuitabletodistinguishfrontotemporaldementiafrompsychiatricdiseases
AT scheltensphilip urineasmatrixforanalysisofneurofilamentlightchainisnotsuitabletodistinguishfrontotemporaldementiafrompsychiatricdiseases
AT vijverbergeverardgb urineasmatrixforanalysisofneurofilamentlightchainisnotsuitabletodistinguishfrontotemporaldementiafrompsychiatricdiseases
AT pijnenburgyolandeal urineasmatrixforanalysisofneurofilamentlightchainisnotsuitabletodistinguishfrontotemporaldementiafrompsychiatricdiseases
AT teunissencharlottee urineasmatrixforanalysisofneurofilamentlightchainisnotsuitabletodistinguishfrontotemporaldementiafrompsychiatricdiseases