Bacterial Assessment of Stethoscopes Used by Healthcare Workers at a Tertiary Care Government Hospital in Bharatpur, Nepal

The transmission of healthcare-associated infections (HCAIs) in healthcare settings is a serious challenge in the medical fraternity. Medical devices, such as stethoscopes used by healthcare workers (HCWs), are likely to harbor a considerable number of pathogenic microbes, which may result in the tr...

Descripción completa

Detalles Bibliográficos
Autores principales: Adhikari, Sanjib, Adhikaree, Neetu, Paudel, Krishna Prasad, Nepal, Roshan, Poudel, Birendra, Giri, Sujan, Khadka, Suman, Khawas, Saphala, Sapkota, Sanjeep, Regmi, Ramesh Sharma, Rijal, Komal Raj
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10123714/
https://www.ncbi.nlm.nih.gov/pubmed/37092437
http://dx.doi.org/10.3390/diseases11020055
Descripción
Sumario:The transmission of healthcare-associated infections (HCAIs) in healthcare settings is a serious challenge in the medical fraternity. Medical devices, such as stethoscopes used by healthcare workers (HCWs), are likely to harbor a considerable number of pathogenic microbes, which may result in the transmission of HCAIs. This study sought to investigate bacterial contamination of stethoscopes used by HCWs at Bharatpur Hospital, Nepal. During the study period of 3 months from December 2019 to February 2020, a total of 87 stethoscopes were examined; bacterial pathogens were isolated and identified by culture and biochemical tests, and their susceptibilities against different antibiotics were determined using standard protocols of the Clinical and Laboratory Standards Institute (CLSI). The disc diffusion method was used primarily to screen for extended-spectrum beta-lactamase (ESBL)- and metallo-beta-lactamase (MBL)-producing isolates, followed by their confirmation using cephalosporin/clavulanate combination discs and the disc potentiation methods, respectively. In addition, molecular detection of bla(CTX-M) and bla(VIM) genes was performed using conventional polymerase chain reaction (PCR). Of the 87 stethoscopes examined, more than a quarter (28.7%) were colonized with different pathogenic bacteria. Bacterial contamination of stethoscopes was found to be significantly associated with various factors, such as disinfecting routine, method of disinfection, and department of the hospital (p < 0.05). A higher rate of bacterial contamination was observed on the diaphragm of the stethoscope (12.64%) and among HCWs who overlooked hand hygiene practices (45.45%). The prevalence of methicillin-resistant S. aureus (MRSA) was 44.44%, and approximately half of the Gram-negative isolates (47%) were multidrug resistant (MDR). Imipenem (81.25%) and chloramphenicol (83.33%) were found to be the most effective antibiotics for Gram-negative and Gram-positive bacteria, respectively. Phenotypic screening showed that 43.75% of isolates were ESBL producers, and 18.75% were MBL producers, but bla(CTX-M) and bla(VIM) genes were detected in only 31.25% and 6.25% of isolates, respectively. The results of the study call for effective stethoscope disinfection practices along with the judicious use of antibiotics by HCWs in order to minimize cross-contamination, emergence of resistance, and spread of nosocomial infections in clinical settings.