Cargando…
Observer agreement of volar tilt of the wrist is influenced by forearm rotation
BACKGROUND: Dorsal/volar tilt is an important radiographic measurement commonly included in the treatment decision of distal radius fractures (DRFs). However, studies have shown that forearm positioning relative to rotation (i.e., supination and pronation) can affect the measured tilt value but with...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10123885/ https://www.ncbi.nlm.nih.gov/pubmed/37101460 http://dx.doi.org/10.1177/20584601231167146 |
_version_ | 1785029743752511488 |
---|---|
author | Emma Mathilde Kirkeby, Jensen Jensen, Janni S Benjamin, Rasmussen B Hans, Tromborg Graumann, Ole |
author_facet | Emma Mathilde Kirkeby, Jensen Jensen, Janni S Benjamin, Rasmussen B Hans, Tromborg Graumann, Ole |
author_sort | Emma Mathilde Kirkeby, Jensen |
collection | PubMed |
description | BACKGROUND: Dorsal/volar tilt is an important radiographic measurement commonly included in the treatment decision of distal radius fractures (DRFs). However, studies have shown that forearm positioning relative to rotation (i.e., supination and pronation) can affect the measured tilt value but with substantial interobserver variance. PURPOSE: To examine whether interobserver agreement on radiographic tilt measurement is influenced by forearm rotation. MATERIAL AND METHODS: We radiographed 21 cadaveric forearms at 5° rotational intervals between 15° supination and 15° pronation on lateral radiographs. A radiologist and a hand surgeon measured tilt in a blinded and randomized fashion. Bland–Altman analyses with bias and limits of agreement (LoA) were used to estimate interobserver agreement for forearms in all degrees of rotation, non-rotated forearms, supinated forearms, and pronated forearms. RESULTS: Interobserver agreement varied with forearm rotation. Bias (95% confidence interval [CI]; LoA) was −1.54° (95% CI: −2.53, −0.55; LoA: −13.46, 10.38) when measuring tilt on radiographs with all degrees of forearm rotation, and −1.48° (95% CI: −4.13, 1.17; LoA: −12.88, 9.92) when measuring tilt on true lateral 0° radiographs. When measuring on supinated and pronated radiographs, bias was −0.03° (95% CI: −1.35, 1.29; LoA: −8.34, 8.28) and −3.23° (95% CI: −5.41, −1.06; LoA: −16.90, 10.44), respectively. CONCLUSION: Interobserver agreement on tilt was similar when comparing measurements made on true lateral radiographs to those made on the group with all degrees of forearm rotation. However, interobserver agreement improved with supination and worsened with pronation. |
format | Online Article Text |
id | pubmed-10123885 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-101238852023-04-25 Observer agreement of volar tilt of the wrist is influenced by forearm rotation Emma Mathilde Kirkeby, Jensen Jensen, Janni S Benjamin, Rasmussen B Hans, Tromborg Graumann, Ole Acta Radiol Open Original Article BACKGROUND: Dorsal/volar tilt is an important radiographic measurement commonly included in the treatment decision of distal radius fractures (DRFs). However, studies have shown that forearm positioning relative to rotation (i.e., supination and pronation) can affect the measured tilt value but with substantial interobserver variance. PURPOSE: To examine whether interobserver agreement on radiographic tilt measurement is influenced by forearm rotation. MATERIAL AND METHODS: We radiographed 21 cadaveric forearms at 5° rotational intervals between 15° supination and 15° pronation on lateral radiographs. A radiologist and a hand surgeon measured tilt in a blinded and randomized fashion. Bland–Altman analyses with bias and limits of agreement (LoA) were used to estimate interobserver agreement for forearms in all degrees of rotation, non-rotated forearms, supinated forearms, and pronated forearms. RESULTS: Interobserver agreement varied with forearm rotation. Bias (95% confidence interval [CI]; LoA) was −1.54° (95% CI: −2.53, −0.55; LoA: −13.46, 10.38) when measuring tilt on radiographs with all degrees of forearm rotation, and −1.48° (95% CI: −4.13, 1.17; LoA: −12.88, 9.92) when measuring tilt on true lateral 0° radiographs. When measuring on supinated and pronated radiographs, bias was −0.03° (95% CI: −1.35, 1.29; LoA: −8.34, 8.28) and −3.23° (95% CI: −5.41, −1.06; LoA: −16.90, 10.44), respectively. CONCLUSION: Interobserver agreement on tilt was similar when comparing measurements made on true lateral radiographs to those made on the group with all degrees of forearm rotation. However, interobserver agreement improved with supination and worsened with pronation. SAGE Publications 2023-04-17 /pmc/articles/PMC10123885/ /pubmed/37101460 http://dx.doi.org/10.1177/20584601231167146 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Article Emma Mathilde Kirkeby, Jensen Jensen, Janni S Benjamin, Rasmussen B Hans, Tromborg Graumann, Ole Observer agreement of volar tilt of the wrist is influenced by forearm rotation |
title | Observer agreement of volar tilt of the wrist is influenced by forearm rotation |
title_full | Observer agreement of volar tilt of the wrist is influenced by forearm rotation |
title_fullStr | Observer agreement of volar tilt of the wrist is influenced by forearm rotation |
title_full_unstemmed | Observer agreement of volar tilt of the wrist is influenced by forearm rotation |
title_short | Observer agreement of volar tilt of the wrist is influenced by forearm rotation |
title_sort | observer agreement of volar tilt of the wrist is influenced by forearm rotation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10123885/ https://www.ncbi.nlm.nih.gov/pubmed/37101460 http://dx.doi.org/10.1177/20584601231167146 |
work_keys_str_mv | AT emmamathildekirkebyjensen observeragreementofvolartiltofthewristisinfluencedbyforearmrotation AT jensenjanni observeragreementofvolartiltofthewristisinfluencedbyforearmrotation AT sbenjaminrasmussen observeragreementofvolartiltofthewristisinfluencedbyforearmrotation AT bhanstromborg observeragreementofvolartiltofthewristisinfluencedbyforearmrotation AT graumannole observeragreementofvolartiltofthewristisinfluencedbyforearmrotation |