Cargando…

Comparison of clinical outcomes between intense pulsed light therapy using two different filters in meibomian gland dysfunction: prospective randomized study

Our study compared treatment efficacy between cut-off and notch filters in intense pulsed light (IPL) therapy for meibomian gland dysfunction (MGD) through a prospective, randomized paired-eye trial. Additionally, the efficacy of IPL treatment alone was investigated by restricting other conventional...

Descripción completa

Detalles Bibliográficos
Autores principales: Jang, Joon Hyuck, Lee, Koeun, Nam, Sang Hyu, Kim, Jin, Kim, Jae Yong, Tchah, Hungwon, Lee, Hun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10126147/
https://www.ncbi.nlm.nih.gov/pubmed/37095152
http://dx.doi.org/10.1038/s41598-023-33526-z
_version_ 1785030176042647552
author Jang, Joon Hyuck
Lee, Koeun
Nam, Sang Hyu
Kim, Jin
Kim, Jae Yong
Tchah, Hungwon
Lee, Hun
author_facet Jang, Joon Hyuck
Lee, Koeun
Nam, Sang Hyu
Kim, Jin
Kim, Jae Yong
Tchah, Hungwon
Lee, Hun
author_sort Jang, Joon Hyuck
collection PubMed
description Our study compared treatment efficacy between cut-off and notch filters in intense pulsed light (IPL) therapy for meibomian gland dysfunction (MGD) through a prospective, randomized paired-eye trial. Additionally, the efficacy of IPL treatment alone was investigated by restricting other conventional treatments. One eye was randomly selected for an acne filter and the other for a 590-nm filter. Identical four regimens of IPL treatments were administered. The tear break-up time (TBUT), Oxford scale, Sjögren’s International Clinical Collaborative Alliance (SICCA) staining score, tear matrix metalloproteinase-9 (MMP-9) expression, tear osmolarity, and Ocular Surface Disease Index (OSDI) questionnaires were evaluated before and after IPL. Meibomian gland (MG) parameters were measured. When combining the results from both filters, the TBUT, SICCA staining score, OSDI score, and upper and lower lid meibum expressibility were improved after IPL. No significant differences were found between the two filters in the TBUT, Oxford scale, SICCA staining score, MMP-9 expression, tear osmolarity, and MG parameters. Although not significant, the acne filter showed better treatment efficacy than that in the 590-nm filter. IPL alone is efficacious in terms of ocular surface parameters, MG function, and subjective symptoms. Regarding filter selection, both acne and 590-nm filters are promising options for MGD treatment.
format Online
Article
Text
id pubmed-10126147
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-101261472023-04-26 Comparison of clinical outcomes between intense pulsed light therapy using two different filters in meibomian gland dysfunction: prospective randomized study Jang, Joon Hyuck Lee, Koeun Nam, Sang Hyu Kim, Jin Kim, Jae Yong Tchah, Hungwon Lee, Hun Sci Rep Article Our study compared treatment efficacy between cut-off and notch filters in intense pulsed light (IPL) therapy for meibomian gland dysfunction (MGD) through a prospective, randomized paired-eye trial. Additionally, the efficacy of IPL treatment alone was investigated by restricting other conventional treatments. One eye was randomly selected for an acne filter and the other for a 590-nm filter. Identical four regimens of IPL treatments were administered. The tear break-up time (TBUT), Oxford scale, Sjögren’s International Clinical Collaborative Alliance (SICCA) staining score, tear matrix metalloproteinase-9 (MMP-9) expression, tear osmolarity, and Ocular Surface Disease Index (OSDI) questionnaires were evaluated before and after IPL. Meibomian gland (MG) parameters were measured. When combining the results from both filters, the TBUT, SICCA staining score, OSDI score, and upper and lower lid meibum expressibility were improved after IPL. No significant differences were found between the two filters in the TBUT, Oxford scale, SICCA staining score, MMP-9 expression, tear osmolarity, and MG parameters. Although not significant, the acne filter showed better treatment efficacy than that in the 590-nm filter. IPL alone is efficacious in terms of ocular surface parameters, MG function, and subjective symptoms. Regarding filter selection, both acne and 590-nm filters are promising options for MGD treatment. Nature Publishing Group UK 2023-04-24 /pmc/articles/PMC10126147/ /pubmed/37095152 http://dx.doi.org/10.1038/s41598-023-33526-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Jang, Joon Hyuck
Lee, Koeun
Nam, Sang Hyu
Kim, Jin
Kim, Jae Yong
Tchah, Hungwon
Lee, Hun
Comparison of clinical outcomes between intense pulsed light therapy using two different filters in meibomian gland dysfunction: prospective randomized study
title Comparison of clinical outcomes between intense pulsed light therapy using two different filters in meibomian gland dysfunction: prospective randomized study
title_full Comparison of clinical outcomes between intense pulsed light therapy using two different filters in meibomian gland dysfunction: prospective randomized study
title_fullStr Comparison of clinical outcomes between intense pulsed light therapy using two different filters in meibomian gland dysfunction: prospective randomized study
title_full_unstemmed Comparison of clinical outcomes between intense pulsed light therapy using two different filters in meibomian gland dysfunction: prospective randomized study
title_short Comparison of clinical outcomes between intense pulsed light therapy using two different filters in meibomian gland dysfunction: prospective randomized study
title_sort comparison of clinical outcomes between intense pulsed light therapy using two different filters in meibomian gland dysfunction: prospective randomized study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10126147/
https://www.ncbi.nlm.nih.gov/pubmed/37095152
http://dx.doi.org/10.1038/s41598-023-33526-z
work_keys_str_mv AT jangjoonhyuck comparisonofclinicaloutcomesbetweenintensepulsedlighttherapyusingtwodifferentfiltersinmeibomianglanddysfunctionprospectiverandomizedstudy
AT leekoeun comparisonofclinicaloutcomesbetweenintensepulsedlighttherapyusingtwodifferentfiltersinmeibomianglanddysfunctionprospectiverandomizedstudy
AT namsanghyu comparisonofclinicaloutcomesbetweenintensepulsedlighttherapyusingtwodifferentfiltersinmeibomianglanddysfunctionprospectiverandomizedstudy
AT kimjin comparisonofclinicaloutcomesbetweenintensepulsedlighttherapyusingtwodifferentfiltersinmeibomianglanddysfunctionprospectiverandomizedstudy
AT kimjaeyong comparisonofclinicaloutcomesbetweenintensepulsedlighttherapyusingtwodifferentfiltersinmeibomianglanddysfunctionprospectiverandomizedstudy
AT tchahhungwon comparisonofclinicaloutcomesbetweenintensepulsedlighttherapyusingtwodifferentfiltersinmeibomianglanddysfunctionprospectiverandomizedstudy
AT leehun comparisonofclinicaloutcomesbetweenintensepulsedlighttherapyusingtwodifferentfiltersinmeibomianglanddysfunctionprospectiverandomizedstudy