Cargando…

Detectable depth of unexposed parathyroid glands using near-infrared autofluorescence imaging in thyroid surgery

BACKGROUND: Near-infrared light can penetrate the fat or connective tissues overlying the parathyroid gland (PG), enabling early localization of the PG by near-infrared autofluorescence (NIRAF) imaging. However, the depth at which the PG can be detected has not been reported. In this study, we inves...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Young Seok, Kim, Yikeun, Lee, Hyoung Shin, Kim, Yeongjoon, Ahn, Yeh-Chan, Lee, Kang Dae
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10126413/
https://www.ncbi.nlm.nih.gov/pubmed/37113485
http://dx.doi.org/10.3389/fendo.2023.1170751
_version_ 1785030238176018432
author Han, Young Seok
Kim, Yikeun
Lee, Hyoung Shin
Kim, Yeongjoon
Ahn, Yeh-Chan
Lee, Kang Dae
author_facet Han, Young Seok
Kim, Yikeun
Lee, Hyoung Shin
Kim, Yeongjoon
Ahn, Yeh-Chan
Lee, Kang Dae
author_sort Han, Young Seok
collection PubMed
description BACKGROUND: Near-infrared light can penetrate the fat or connective tissues overlying the parathyroid gland (PG), enabling early localization of the PG by near-infrared autofluorescence (NIRAF) imaging. However, the depth at which the PG can be detected has not been reported. In this study, we investigated the detectable depth of unexposed PGs using NIRAF during thyroidectomy. MATERIALS AND METHODS: Fifty-one unexposed PGs from 30 consecutive thyroidectomy patients, mapped by an experienced surgeon (K.D. Lee) with the use of NIRAF imaging, were included. For NIRAF detection of PGs, a lab-built camera imaging system was used. Detectable depths of the unexposed PGs were measured using a Vernier caliper. The NIRAF images were classified as faint or bright depending on whether a novice could successfully interpret the image as showing the PG. Data on variables that may affect detectable depth and NIRAF intensity were collected. RESULTS: Detectable depth ranged between 0.35 and 3.05 mm, with a mean of 1.23 ± 0.73 mm. The average NIRAF intensity of unexposed PGs was 3.13 au. After dissection of the overlying tissue, the intensity of the exposed PG increased to 4.88 au (p < 0.001). No difference in NIRAF intensity between fat-covered (3.27 ± 0.90 au) and connective tissue-covered PGs (3.00 ± 1.23 au) was observed (p = 0.369). PGs covered by fat tissue (depth: 1.77 ± 0.67 mm) were found at deeper locations than those covered by connective tissue (depth: 0.70 ± 0.21 mm) (p < 0.001). The brightness of images of the faint group (2.14 ± 0.48 au) was on average 1.24 au lower than that of the bright group (3.38 ± 1.04 au) (p = 0.001). A novice successfully localized 80.4% of the unexposed PGs. Other variables did not significantly affect detectable depth. CONCLUSION: Unexposed PGs could be mapped using NIRAF imaging at a maximum depth of 3.05 mm and an average depth of 1.23 mm. A novice was able to localize the PGs before they were visible to the naked eye at a high rate. These results can be used as reference data for localization of unexposed PGs in thyroid surgery.
format Online
Article
Text
id pubmed-10126413
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-101264132023-04-26 Detectable depth of unexposed parathyroid glands using near-infrared autofluorescence imaging in thyroid surgery Han, Young Seok Kim, Yikeun Lee, Hyoung Shin Kim, Yeongjoon Ahn, Yeh-Chan Lee, Kang Dae Front Endocrinol (Lausanne) Endocrinology BACKGROUND: Near-infrared light can penetrate the fat or connective tissues overlying the parathyroid gland (PG), enabling early localization of the PG by near-infrared autofluorescence (NIRAF) imaging. However, the depth at which the PG can be detected has not been reported. In this study, we investigated the detectable depth of unexposed PGs using NIRAF during thyroidectomy. MATERIALS AND METHODS: Fifty-one unexposed PGs from 30 consecutive thyroidectomy patients, mapped by an experienced surgeon (K.D. Lee) with the use of NIRAF imaging, were included. For NIRAF detection of PGs, a lab-built camera imaging system was used. Detectable depths of the unexposed PGs were measured using a Vernier caliper. The NIRAF images were classified as faint or bright depending on whether a novice could successfully interpret the image as showing the PG. Data on variables that may affect detectable depth and NIRAF intensity were collected. RESULTS: Detectable depth ranged between 0.35 and 3.05 mm, with a mean of 1.23 ± 0.73 mm. The average NIRAF intensity of unexposed PGs was 3.13 au. After dissection of the overlying tissue, the intensity of the exposed PG increased to 4.88 au (p < 0.001). No difference in NIRAF intensity between fat-covered (3.27 ± 0.90 au) and connective tissue-covered PGs (3.00 ± 1.23 au) was observed (p = 0.369). PGs covered by fat tissue (depth: 1.77 ± 0.67 mm) were found at deeper locations than those covered by connective tissue (depth: 0.70 ± 0.21 mm) (p < 0.001). The brightness of images of the faint group (2.14 ± 0.48 au) was on average 1.24 au lower than that of the bright group (3.38 ± 1.04 au) (p = 0.001). A novice successfully localized 80.4% of the unexposed PGs. Other variables did not significantly affect detectable depth. CONCLUSION: Unexposed PGs could be mapped using NIRAF imaging at a maximum depth of 3.05 mm and an average depth of 1.23 mm. A novice was able to localize the PGs before they were visible to the naked eye at a high rate. These results can be used as reference data for localization of unexposed PGs in thyroid surgery. Frontiers Media S.A. 2023-04-11 /pmc/articles/PMC10126413/ /pubmed/37113485 http://dx.doi.org/10.3389/fendo.2023.1170751 Text en Copyright © 2023 Han, Kim, Lee, Kim, Ahn and Lee https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Endocrinology
Han, Young Seok
Kim, Yikeun
Lee, Hyoung Shin
Kim, Yeongjoon
Ahn, Yeh-Chan
Lee, Kang Dae
Detectable depth of unexposed parathyroid glands using near-infrared autofluorescence imaging in thyroid surgery
title Detectable depth of unexposed parathyroid glands using near-infrared autofluorescence imaging in thyroid surgery
title_full Detectable depth of unexposed parathyroid glands using near-infrared autofluorescence imaging in thyroid surgery
title_fullStr Detectable depth of unexposed parathyroid glands using near-infrared autofluorescence imaging in thyroid surgery
title_full_unstemmed Detectable depth of unexposed parathyroid glands using near-infrared autofluorescence imaging in thyroid surgery
title_short Detectable depth of unexposed parathyroid glands using near-infrared autofluorescence imaging in thyroid surgery
title_sort detectable depth of unexposed parathyroid glands using near-infrared autofluorescence imaging in thyroid surgery
topic Endocrinology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10126413/
https://www.ncbi.nlm.nih.gov/pubmed/37113485
http://dx.doi.org/10.3389/fendo.2023.1170751
work_keys_str_mv AT hanyoungseok detectabledepthofunexposedparathyroidglandsusingnearinfraredautofluorescenceimaginginthyroidsurgery
AT kimyikeun detectabledepthofunexposedparathyroidglandsusingnearinfraredautofluorescenceimaginginthyroidsurgery
AT leehyoungshin detectabledepthofunexposedparathyroidglandsusingnearinfraredautofluorescenceimaginginthyroidsurgery
AT kimyeongjoon detectabledepthofunexposedparathyroidglandsusingnearinfraredautofluorescenceimaginginthyroidsurgery
AT ahnyehchan detectabledepthofunexposedparathyroidglandsusingnearinfraredautofluorescenceimaginginthyroidsurgery
AT leekangdae detectabledepthofunexposedparathyroidglandsusingnearinfraredautofluorescenceimaginginthyroidsurgery