Cargando…

Prognostic value of post-procedural μQFR for drug-coated balloons in the treatment of in-stent restenosis

BACKGROUND: Investigating the prognostic value of the Murray law-based quantitative flow ratio (μQFR) on the clinical outcome after treatment of in-stent restenosis (ISR) with a drug-coated balloon (DCB). METHODS: Patients participating in a previous randomized clinical trial for DCB-ISR were post-h...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Lili, Ding, Fenghua, Gutiérrez-Chico, Juan Luis, Zhu, Jinzhou, Zhu, Zhengbin, Du, Run, Yang, Zhenkun, Hu, Jian, Tu, Shengxian, Zhang, Ruiyan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Via Medica 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10129249/
https://www.ncbi.nlm.nih.gov/pubmed/34811717
http://dx.doi.org/10.5603/CJ.a2021.0154
_version_ 1785030692093034496
author Liu, Lili
Ding, Fenghua
Gutiérrez-Chico, Juan Luis
Zhu, Jinzhou
Zhu, Zhengbin
Du, Run
Yang, Zhenkun
Hu, Jian
Tu, Shengxian
Zhang, Ruiyan
author_facet Liu, Lili
Ding, Fenghua
Gutiérrez-Chico, Juan Luis
Zhu, Jinzhou
Zhu, Zhengbin
Du, Run
Yang, Zhenkun
Hu, Jian
Tu, Shengxian
Zhang, Ruiyan
author_sort Liu, Lili
collection PubMed
description BACKGROUND: Investigating the prognostic value of the Murray law-based quantitative flow ratio (μQFR) on the clinical outcome after treatment of in-stent restenosis (ISR) with a drug-coated balloon (DCB). METHODS: Patients participating in a previous randomized clinical trial for DCB-ISR were post-hoc analyzed. The primary endpoint was vessel-oriented composite endpoint (VOCE), defined as cardiac death, target vessel-related myocardial infarction, and ischemia-driven target vessel revascularization. μQFRs at baseline and after DCB angioplasty was calculated, and its prognostic value as a predictor of VOCE was explored in Cox regression. RESULTS: A total of 169 lesions in 169 patients were analyzed. At 1-year follow-up, 20 VOCEs occurred in 20 patients. Receiver-operating characteristic curve analysis identified a post-procedural μQFR of ≤ 0.89 as the best cut-off to predict VOCE (area under curve [AUC]: 0.74; 95% confidence interval [CI]: 0.67–0.80; p < 0.001), superior to post-procedural in-stent percent diameter stenosis, which reported an AUC of 0.61 (95% CI: 0.53–0.68; p = 0.18). Post-procedural μQFR was significantly lower in patients with VOCE compared with those without (0.88 [interquartile range: 0.79–0.94] vs. 0.96 [interquartile range: 0.91–0.98], respectively; p < 0.001). After correction for potential confounders, post-procedural μQFR ≤ 0.89 was associated with a 6-fold higher risk of VOCE than lesions with μQFR > 0.89 (hazard ratio: 5.94; 95% CI: 2.33–15.09; p < 0.001). CONCLUSIONS: Post-procedural μQFR may become a promising predictor of clinical outcome after treatment of DES-ISR lesions by DCB angioplasty.
format Online
Article
Text
id pubmed-10129249
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Via Medica
record_format MEDLINE/PubMed
spelling pubmed-101292492023-04-26 Prognostic value of post-procedural μQFR for drug-coated balloons in the treatment of in-stent restenosis Liu, Lili Ding, Fenghua Gutiérrez-Chico, Juan Luis Zhu, Jinzhou Zhu, Zhengbin Du, Run Yang, Zhenkun Hu, Jian Tu, Shengxian Zhang, Ruiyan Cardiol J Interventional Cardiology BACKGROUND: Investigating the prognostic value of the Murray law-based quantitative flow ratio (μQFR) on the clinical outcome after treatment of in-stent restenosis (ISR) with a drug-coated balloon (DCB). METHODS: Patients participating in a previous randomized clinical trial for DCB-ISR were post-hoc analyzed. The primary endpoint was vessel-oriented composite endpoint (VOCE), defined as cardiac death, target vessel-related myocardial infarction, and ischemia-driven target vessel revascularization. μQFRs at baseline and after DCB angioplasty was calculated, and its prognostic value as a predictor of VOCE was explored in Cox regression. RESULTS: A total of 169 lesions in 169 patients were analyzed. At 1-year follow-up, 20 VOCEs occurred in 20 patients. Receiver-operating characteristic curve analysis identified a post-procedural μQFR of ≤ 0.89 as the best cut-off to predict VOCE (area under curve [AUC]: 0.74; 95% confidence interval [CI]: 0.67–0.80; p < 0.001), superior to post-procedural in-stent percent diameter stenosis, which reported an AUC of 0.61 (95% CI: 0.53–0.68; p = 0.18). Post-procedural μQFR was significantly lower in patients with VOCE compared with those without (0.88 [interquartile range: 0.79–0.94] vs. 0.96 [interquartile range: 0.91–0.98], respectively; p < 0.001). After correction for potential confounders, post-procedural μQFR ≤ 0.89 was associated with a 6-fold higher risk of VOCE than lesions with μQFR > 0.89 (hazard ratio: 5.94; 95% CI: 2.33–15.09; p < 0.001). CONCLUSIONS: Post-procedural μQFR may become a promising predictor of clinical outcome after treatment of DES-ISR lesions by DCB angioplasty. Via Medica 2023-04-17 /pmc/articles/PMC10129249/ /pubmed/34811717 http://dx.doi.org/10.5603/CJ.a2021.0154 Text en Copyright © 2023 Via Medica https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially
spellingShingle Interventional Cardiology
Liu, Lili
Ding, Fenghua
Gutiérrez-Chico, Juan Luis
Zhu, Jinzhou
Zhu, Zhengbin
Du, Run
Yang, Zhenkun
Hu, Jian
Tu, Shengxian
Zhang, Ruiyan
Prognostic value of post-procedural μQFR for drug-coated balloons in the treatment of in-stent restenosis
title Prognostic value of post-procedural μQFR for drug-coated balloons in the treatment of in-stent restenosis
title_full Prognostic value of post-procedural μQFR for drug-coated balloons in the treatment of in-stent restenosis
title_fullStr Prognostic value of post-procedural μQFR for drug-coated balloons in the treatment of in-stent restenosis
title_full_unstemmed Prognostic value of post-procedural μQFR for drug-coated balloons in the treatment of in-stent restenosis
title_short Prognostic value of post-procedural μQFR for drug-coated balloons in the treatment of in-stent restenosis
title_sort prognostic value of post-procedural μqfr for drug-coated balloons in the treatment of in-stent restenosis
topic Interventional Cardiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10129249/
https://www.ncbi.nlm.nih.gov/pubmed/34811717
http://dx.doi.org/10.5603/CJ.a2021.0154
work_keys_str_mv AT liulili prognosticvalueofpostproceduralmqfrfordrugcoatedballoonsinthetreatmentofinstentrestenosis
AT dingfenghua prognosticvalueofpostproceduralmqfrfordrugcoatedballoonsinthetreatmentofinstentrestenosis
AT gutierrezchicojuanluis prognosticvalueofpostproceduralmqfrfordrugcoatedballoonsinthetreatmentofinstentrestenosis
AT zhujinzhou prognosticvalueofpostproceduralmqfrfordrugcoatedballoonsinthetreatmentofinstentrestenosis
AT zhuzhengbin prognosticvalueofpostproceduralmqfrfordrugcoatedballoonsinthetreatmentofinstentrestenosis
AT durun prognosticvalueofpostproceduralmqfrfordrugcoatedballoonsinthetreatmentofinstentrestenosis
AT yangzhenkun prognosticvalueofpostproceduralmqfrfordrugcoatedballoonsinthetreatmentofinstentrestenosis
AT hujian prognosticvalueofpostproceduralmqfrfordrugcoatedballoonsinthetreatmentofinstentrestenosis
AT tushengxian prognosticvalueofpostproceduralmqfrfordrugcoatedballoonsinthetreatmentofinstentrestenosis
AT zhangruiyan prognosticvalueofpostproceduralmqfrfordrugcoatedballoonsinthetreatmentofinstentrestenosis