Cargando…

64 Finite Element Analysis of a Porous Dual Component 3D-Printed Bone Graft for Alveolar Ridge Augmentation

OBJECTIVES/GOALS: Our goal was to assess the ability of a 3D-Printed dual cover-core design alveolar ridge bone graft, to withstand the average maximum masticatory force of a healthy person. To this end, we characterized the materials, ran a finite element analysis (FEA) model, and validated it usin...

Descripción completa

Detalles Bibliográficos
Autores principales: Benito Alston, Claudia, Villareal, Cameron, Moldovan, Nicanor, Roudebush, Richard L., Barco, Clark, Chan, Deva, Solorio, Luis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cambridge University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10129633/
http://dx.doi.org/10.1017/cts.2023.151
_version_ 1785030790518669312
author Benito Alston, Claudia
Villareal, Cameron
Moldovan, Nicanor
Roudebush, Richard L.
Barco, Clark
Roudebush, Richard L.
Chan, Deva
Solorio, Luis
author_facet Benito Alston, Claudia
Villareal, Cameron
Moldovan, Nicanor
Roudebush, Richard L.
Barco, Clark
Roudebush, Richard L.
Chan, Deva
Solorio, Luis
author_sort Benito Alston, Claudia
collection PubMed
description OBJECTIVES/GOALS: Our goal was to assess the ability of a 3D-Printed dual cover-core design alveolar ridge bone graft, to withstand the average maximum masticatory force of a healthy person. To this end, we characterized the materials, ran a finite element analysis (FEA) model, and validated it using a resin 3D-printed version tested under compression with strain gauges. METHODS/STUDY POPULATION: A tricalcium-phosphate/hydroxyapatite paste and mixed methacrylated alginate-gelatin were used for the core, and polycaprolactone for the cover. These were characterized using ASTM standards D695 and D638 for compression, tensile, and rheological testing. Then we converted cone CT-scan images of a mandibular alveolar ridge defect to an .stl file, and designed the cover and core in Meshmixer. The model was then imported into ANSYS 11.0, and a downward compression force of 500 N, the maximum masticatory force of a healthy adult, was applied on the graft and mandible’s top ridge. The different models included solid and porous covers and cores, as well as comparing screws on one or both sides of the cover, then validated by compressing a resin 3D-printed versions. RESULTS/ANTICIPATED RESULTS: The FEA model provided maximum displacements, Von Mises stress (VMS), and stress/strain values for each model. The highest maximum displacement was found on the solid covers with a combination of both buccal and lingual screws, at 0.162 mm. The lowest maximum displacement was found in the porous cover at 0.085 mm. All VMS values were below the tensile yield strength, meaning that the materials would not yield. The highest maximum stress was found on the porous cover at 13.52 MPa, the lowest was 1.06 MPa on the cover with no screws. The highest strain was found on the porous model at 0.010, which was 5.6x higher than the solid cover. The porous cover also showed less stress shielding, thus allowing a beneficial mechanical stimulation of the bone, and the lowest maximum displacement, possibly due to flexion through the pores. DISCUSSION/SIGNIFICANCE: Preliminary FEA models demonstrated that for the considered materials, a cover-core design of the mandibular implant would sustain the desired 500 N of force without yielding. The porous cover provides the most benefits, causing the least stress shielding and allowing diffusion of biological factors to support the osteoinductive role of the core.
format Online
Article
Text
id pubmed-10129633
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cambridge University Press
record_format MEDLINE/PubMed
spelling pubmed-101296332023-04-26 64 Finite Element Analysis of a Porous Dual Component 3D-Printed Bone Graft for Alveolar Ridge Augmentation Benito Alston, Claudia Villareal, Cameron Moldovan, Nicanor Roudebush, Richard L. Barco, Clark Roudebush, Richard L. Chan, Deva Solorio, Luis J Clin Transl Sci Biostatistics, Epidemiology, and Research Design OBJECTIVES/GOALS: Our goal was to assess the ability of a 3D-Printed dual cover-core design alveolar ridge bone graft, to withstand the average maximum masticatory force of a healthy person. To this end, we characterized the materials, ran a finite element analysis (FEA) model, and validated it using a resin 3D-printed version tested under compression with strain gauges. METHODS/STUDY POPULATION: A tricalcium-phosphate/hydroxyapatite paste and mixed methacrylated alginate-gelatin were used for the core, and polycaprolactone for the cover. These were characterized using ASTM standards D695 and D638 for compression, tensile, and rheological testing. Then we converted cone CT-scan images of a mandibular alveolar ridge defect to an .stl file, and designed the cover and core in Meshmixer. The model was then imported into ANSYS 11.0, and a downward compression force of 500 N, the maximum masticatory force of a healthy adult, was applied on the graft and mandible’s top ridge. The different models included solid and porous covers and cores, as well as comparing screws on one or both sides of the cover, then validated by compressing a resin 3D-printed versions. RESULTS/ANTICIPATED RESULTS: The FEA model provided maximum displacements, Von Mises stress (VMS), and stress/strain values for each model. The highest maximum displacement was found on the solid covers with a combination of both buccal and lingual screws, at 0.162 mm. The lowest maximum displacement was found in the porous cover at 0.085 mm. All VMS values were below the tensile yield strength, meaning that the materials would not yield. The highest maximum stress was found on the porous cover at 13.52 MPa, the lowest was 1.06 MPa on the cover with no screws. The highest strain was found on the porous model at 0.010, which was 5.6x higher than the solid cover. The porous cover also showed less stress shielding, thus allowing a beneficial mechanical stimulation of the bone, and the lowest maximum displacement, possibly due to flexion through the pores. DISCUSSION/SIGNIFICANCE: Preliminary FEA models demonstrated that for the considered materials, a cover-core design of the mandibular implant would sustain the desired 500 N of force without yielding. The porous cover provides the most benefits, causing the least stress shielding and allowing diffusion of biological factors to support the osteoinductive role of the core. Cambridge University Press 2023-04-24 /pmc/articles/PMC10129633/ http://dx.doi.org/10.1017/cts.2023.151 Text en © The Association for Clinical and Translational Science 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article, distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is unaltered and is properly cited. The written permission of Cambridge University Press must be obtained for commercial re-use or in order to create a derivative work.
spellingShingle Biostatistics, Epidemiology, and Research Design
Benito Alston, Claudia
Villareal, Cameron
Moldovan, Nicanor
Roudebush, Richard L.
Barco, Clark
Roudebush, Richard L.
Chan, Deva
Solorio, Luis
64 Finite Element Analysis of a Porous Dual Component 3D-Printed Bone Graft for Alveolar Ridge Augmentation
title 64 Finite Element Analysis of a Porous Dual Component 3D-Printed Bone Graft for Alveolar Ridge Augmentation
title_full 64 Finite Element Analysis of a Porous Dual Component 3D-Printed Bone Graft for Alveolar Ridge Augmentation
title_fullStr 64 Finite Element Analysis of a Porous Dual Component 3D-Printed Bone Graft for Alveolar Ridge Augmentation
title_full_unstemmed 64 Finite Element Analysis of a Porous Dual Component 3D-Printed Bone Graft for Alveolar Ridge Augmentation
title_short 64 Finite Element Analysis of a Porous Dual Component 3D-Printed Bone Graft for Alveolar Ridge Augmentation
title_sort 64 finite element analysis of a porous dual component 3d-printed bone graft for alveolar ridge augmentation
topic Biostatistics, Epidemiology, and Research Design
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10129633/
http://dx.doi.org/10.1017/cts.2023.151
work_keys_str_mv AT benitoalstonclaudia 64finiteelementanalysisofaporousdualcomponent3dprintedbonegraftforalveolarridgeaugmentation
AT villarealcameron 64finiteelementanalysisofaporousdualcomponent3dprintedbonegraftforalveolarridgeaugmentation
AT moldovannicanor 64finiteelementanalysisofaporousdualcomponent3dprintedbonegraftforalveolarridgeaugmentation
AT roudebushrichardl 64finiteelementanalysisofaporousdualcomponent3dprintedbonegraftforalveolarridgeaugmentation
AT barcoclark 64finiteelementanalysisofaporousdualcomponent3dprintedbonegraftforalveolarridgeaugmentation
AT roudebushrichardl 64finiteelementanalysisofaporousdualcomponent3dprintedbonegraftforalveolarridgeaugmentation
AT chandeva 64finiteelementanalysisofaporousdualcomponent3dprintedbonegraftforalveolarridgeaugmentation
AT solorioluis 64finiteelementanalysisofaporousdualcomponent3dprintedbonegraftforalveolarridgeaugmentation