Cargando…

Computed tomography-based angle measurements of the sagittal capitulum and trochlea position in relation to the humeral shaft

The radiologic evaluation of the sagittal angulation of the distal humerus is commonly based on standard lateral radiographs. However, lateral radiographs do not allow to examine the lateral angulation of the capitulum and the trochlea, separately. Although this problem could be approached via compu...

Descripción completa

Detalles Bibliográficos
Autores principales: Przyklenk, Axel, Hackl, Michael, Iuga, Andra-Iza, Leschinger, Tim, Maintz, David, Harbrecht, Andreas, Müller, Lars Peter, Wegmann, Kilian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Paris 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10130112/
https://www.ncbi.nlm.nih.gov/pubmed/36892617
http://dx.doi.org/10.1007/s00276-023-03118-7
_version_ 1785030900266827776
author Przyklenk, Axel
Hackl, Michael
Iuga, Andra-Iza
Leschinger, Tim
Maintz, David
Harbrecht, Andreas
Müller, Lars Peter
Wegmann, Kilian
author_facet Przyklenk, Axel
Hackl, Michael
Iuga, Andra-Iza
Leschinger, Tim
Maintz, David
Harbrecht, Andreas
Müller, Lars Peter
Wegmann, Kilian
author_sort Przyklenk, Axel
collection PubMed
description The radiologic evaluation of the sagittal angulation of the distal humerus is commonly based on standard lateral radiographs. However, lateral radiographs do not allow to examine the lateral angulation of the capitulum and the trochlea, separately. Although this problem could be approached via computed tomography, there are no data available describing the difference between the angulation of the capitulum and trochlea. Therefore, we aimed to assess sagittal angles of the capitulum and trochlea in relation to the humeral shaft based on 400 CT-scans of the elbow in healthy adults. Angles were measured in sagittal planes at the capitulum center and three anatomically defined trochlea locations and were spanned between the axis of the joint component and the humerus shaft. Angles were tested for differences between measurement locations and correlation with patient characteristics (age, sex, trans-epicondylar distance). Angles increased from lateral to medial measurement locations (107.4 ± 9.6°, 167.4 ± 8.2°, 171.8 ± 7.3°, 179.1 ± 7.0°; p < 0.05). Largest angle differences were detected between the capitulum and trochlea with smallest angles measured at the capitulum. Patient characteristics did not correlate with angles (p > 0.05). Intra-rater-reliability was r = 0.79–0.86. As CT-imaging allows to distinguish between sagittal capitulum and trochlea locations, it might benefit the radiologic diagnostic of sagittal malalignments of the distal humerus at the capitulum and trochlea, separately.
format Online
Article
Text
id pubmed-10130112
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Paris
record_format MEDLINE/PubMed
spelling pubmed-101301122023-04-27 Computed tomography-based angle measurements of the sagittal capitulum and trochlea position in relation to the humeral shaft Przyklenk, Axel Hackl, Michael Iuga, Andra-Iza Leschinger, Tim Maintz, David Harbrecht, Andreas Müller, Lars Peter Wegmann, Kilian Surg Radiol Anat Original Article The radiologic evaluation of the sagittal angulation of the distal humerus is commonly based on standard lateral radiographs. However, lateral radiographs do not allow to examine the lateral angulation of the capitulum and the trochlea, separately. Although this problem could be approached via computed tomography, there are no data available describing the difference between the angulation of the capitulum and trochlea. Therefore, we aimed to assess sagittal angles of the capitulum and trochlea in relation to the humeral shaft based on 400 CT-scans of the elbow in healthy adults. Angles were measured in sagittal planes at the capitulum center and three anatomically defined trochlea locations and were spanned between the axis of the joint component and the humerus shaft. Angles were tested for differences between measurement locations and correlation with patient characteristics (age, sex, trans-epicondylar distance). Angles increased from lateral to medial measurement locations (107.4 ± 9.6°, 167.4 ± 8.2°, 171.8 ± 7.3°, 179.1 ± 7.0°; p < 0.05). Largest angle differences were detected between the capitulum and trochlea with smallest angles measured at the capitulum. Patient characteristics did not correlate with angles (p > 0.05). Intra-rater-reliability was r = 0.79–0.86. As CT-imaging allows to distinguish between sagittal capitulum and trochlea locations, it might benefit the radiologic diagnostic of sagittal malalignments of the distal humerus at the capitulum and trochlea, separately. Springer Paris 2023-03-09 2023 /pmc/articles/PMC10130112/ /pubmed/36892617 http://dx.doi.org/10.1007/s00276-023-03118-7 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Przyklenk, Axel
Hackl, Michael
Iuga, Andra-Iza
Leschinger, Tim
Maintz, David
Harbrecht, Andreas
Müller, Lars Peter
Wegmann, Kilian
Computed tomography-based angle measurements of the sagittal capitulum and trochlea position in relation to the humeral shaft
title Computed tomography-based angle measurements of the sagittal capitulum and trochlea position in relation to the humeral shaft
title_full Computed tomography-based angle measurements of the sagittal capitulum and trochlea position in relation to the humeral shaft
title_fullStr Computed tomography-based angle measurements of the sagittal capitulum and trochlea position in relation to the humeral shaft
title_full_unstemmed Computed tomography-based angle measurements of the sagittal capitulum and trochlea position in relation to the humeral shaft
title_short Computed tomography-based angle measurements of the sagittal capitulum and trochlea position in relation to the humeral shaft
title_sort computed tomography-based angle measurements of the sagittal capitulum and trochlea position in relation to the humeral shaft
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10130112/
https://www.ncbi.nlm.nih.gov/pubmed/36892617
http://dx.doi.org/10.1007/s00276-023-03118-7
work_keys_str_mv AT przyklenkaxel computedtomographybasedanglemeasurementsofthesagittalcapitulumandtrochleapositioninrelationtothehumeralshaft
AT hacklmichael computedtomographybasedanglemeasurementsofthesagittalcapitulumandtrochleapositioninrelationtothehumeralshaft
AT iugaandraiza computedtomographybasedanglemeasurementsofthesagittalcapitulumandtrochleapositioninrelationtothehumeralshaft
AT leschingertim computedtomographybasedanglemeasurementsofthesagittalcapitulumandtrochleapositioninrelationtothehumeralshaft
AT maintzdavid computedtomographybasedanglemeasurementsofthesagittalcapitulumandtrochleapositioninrelationtothehumeralshaft
AT harbrechtandreas computedtomographybasedanglemeasurementsofthesagittalcapitulumandtrochleapositioninrelationtothehumeralshaft
AT mullerlarspeter computedtomographybasedanglemeasurementsofthesagittalcapitulumandtrochleapositioninrelationtothehumeralshaft
AT wegmannkilian computedtomographybasedanglemeasurementsofthesagittalcapitulumandtrochleapositioninrelationtothehumeralshaft