Cargando…

Wrist Accelerometer Estimates of Physical Activity Intensity During Walking in Older Adults and People Living With Complex Health Conditions: Retrospective Observational Data Analysis Study

BACKGROUND: Accurate measurement of daily physical activity (PA) is important as PA is linked to health outcomes in older adults and people living with complex health conditions. Wrist-worn accelerometers are widely used to estimate PA intensity, including walking, which composes much of daily PA. H...

Descripción completa

Detalles Bibliográficos
Autores principales: Weber, Kyle S, Godkin, F Elizabeth, Cornish, Benjamin F, McIlroy, William E, Van Ooteghem, Karen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10131658/
https://www.ncbi.nlm.nih.gov/pubmed/36920452
http://dx.doi.org/10.2196/41685
_version_ 1785031223553294336
author Weber, Kyle S
Godkin, F Elizabeth
Cornish, Benjamin F
McIlroy, William E
Van Ooteghem, Karen
author_facet Weber, Kyle S
Godkin, F Elizabeth
Cornish, Benjamin F
McIlroy, William E
Van Ooteghem, Karen
author_sort Weber, Kyle S
collection PubMed
description BACKGROUND: Accurate measurement of daily physical activity (PA) is important as PA is linked to health outcomes in older adults and people living with complex health conditions. Wrist-worn accelerometers are widely used to estimate PA intensity, including walking, which composes much of daily PA. However, there is concern that wrist-derived PA data in these cohorts is unreliable due to slow gait speed, mobility aid use, disease-related symptoms that impact arm movement, and transient activities of daily living. Despite the potential for error in wrist-derived PA intensity estimates, their use has become ubiquitous in research and clinical application. OBJECTIVE: The goals of this work were to (1) determine the accuracy of wrist-based estimates of PA intensity during known walking periods in older adults and people living with cerebrovascular disease (CVD) or neurodegenerative disease (NDD) and (2) explore factors that influence wrist-derived intensity estimates. METHODS: A total of 35 older adults (n=23 with CVD or NDD) wore an accelerometer on the dominant wrist and ankle for 7 to 10 days of continuous monitoring. Stepping was detected using the ankle accelerometer. Analyses were restricted to gait bouts ≥60 seconds long with a cadence ≥80 steps per minute (LONG walks) to identify periods of purposeful, continuous walking likely to reflect moderate-intensity activity. Wrist accelerometer data were analyzed within LONG walks using 15-second epochs, and published intensity thresholds were applied to classify epochs as sedentary, light, or moderate-to-vigorous physical activity (MVPA). Participants were stratified into quartiles based on the percent of walking epochs classified as sedentary, and the data were examined for differences in behavioral or demographic traits between the top and bottom quartiles. A case series was performed to illustrate factors and behaviors that can affect wrist-derived intensity estimates during walking. RESULTS: Participants averaged 107.7 (SD 55.8) LONG walks with a median cadence of 107.3 (SD 10.8) steps per minute. Across participants, wrist-derived intensity classification was 22.9% (SD 15.8) sedentary, 27.7% (SD 14.6) light, and 49.3% (SD 25.5) MVPA during LONG walks. All participants measured a statistically lower proportion of wrist-derived activity during LONG walks than expected (all P<.001), and 80% (n=28) of participants had at least 20 minutes of LONG walking time misclassified as sedentary based on wrist-derived intensity estimates. Participants in the highest quartile of wrist-derived sedentary classification during LONG walks were significantly older (t(16)=4.24, P<.001) and had more variable wrist movement (t(16)=2.13, P=.049) compared to those in the lowest quartile. CONCLUSIONS: The current best practice wrist accelerometer method is prone to misclassifying activity intensity during walking in older adults and people living with complex health conditions. A multidevice approach may be warranted to advance methods for accurately assessing PA in these groups.
format Online
Article
Text
id pubmed-10131658
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-101316582023-04-27 Wrist Accelerometer Estimates of Physical Activity Intensity During Walking in Older Adults and People Living With Complex Health Conditions: Retrospective Observational Data Analysis Study Weber, Kyle S Godkin, F Elizabeth Cornish, Benjamin F McIlroy, William E Van Ooteghem, Karen JMIR Form Res Original Paper BACKGROUND: Accurate measurement of daily physical activity (PA) is important as PA is linked to health outcomes in older adults and people living with complex health conditions. Wrist-worn accelerometers are widely used to estimate PA intensity, including walking, which composes much of daily PA. However, there is concern that wrist-derived PA data in these cohorts is unreliable due to slow gait speed, mobility aid use, disease-related symptoms that impact arm movement, and transient activities of daily living. Despite the potential for error in wrist-derived PA intensity estimates, their use has become ubiquitous in research and clinical application. OBJECTIVE: The goals of this work were to (1) determine the accuracy of wrist-based estimates of PA intensity during known walking periods in older adults and people living with cerebrovascular disease (CVD) or neurodegenerative disease (NDD) and (2) explore factors that influence wrist-derived intensity estimates. METHODS: A total of 35 older adults (n=23 with CVD or NDD) wore an accelerometer on the dominant wrist and ankle for 7 to 10 days of continuous monitoring. Stepping was detected using the ankle accelerometer. Analyses were restricted to gait bouts ≥60 seconds long with a cadence ≥80 steps per minute (LONG walks) to identify periods of purposeful, continuous walking likely to reflect moderate-intensity activity. Wrist accelerometer data were analyzed within LONG walks using 15-second epochs, and published intensity thresholds were applied to classify epochs as sedentary, light, or moderate-to-vigorous physical activity (MVPA). Participants were stratified into quartiles based on the percent of walking epochs classified as sedentary, and the data were examined for differences in behavioral or demographic traits between the top and bottom quartiles. A case series was performed to illustrate factors and behaviors that can affect wrist-derived intensity estimates during walking. RESULTS: Participants averaged 107.7 (SD 55.8) LONG walks with a median cadence of 107.3 (SD 10.8) steps per minute. Across participants, wrist-derived intensity classification was 22.9% (SD 15.8) sedentary, 27.7% (SD 14.6) light, and 49.3% (SD 25.5) MVPA during LONG walks. All participants measured a statistically lower proportion of wrist-derived activity during LONG walks than expected (all P<.001), and 80% (n=28) of participants had at least 20 minutes of LONG walking time misclassified as sedentary based on wrist-derived intensity estimates. Participants in the highest quartile of wrist-derived sedentary classification during LONG walks were significantly older (t(16)=4.24, P<.001) and had more variable wrist movement (t(16)=2.13, P=.049) compared to those in the lowest quartile. CONCLUSIONS: The current best practice wrist accelerometer method is prone to misclassifying activity intensity during walking in older adults and people living with complex health conditions. A multidevice approach may be warranted to advance methods for accurately assessing PA in these groups. JMIR Publications 2023-03-15 /pmc/articles/PMC10131658/ /pubmed/36920452 http://dx.doi.org/10.2196/41685 Text en ©Kyle S Weber, F Elizabeth Godkin, Benjamin F Cornish, William E McIlroy, Karen Van Ooteghem. Originally published in JMIR Formative Research (https://formative.jmir.org), 15.03.2023. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Formative Research, is properly cited. The complete bibliographic information, a link to the original publication on https://formative.jmir.org, as well as this copyright and license information must be included.
spellingShingle Original Paper
Weber, Kyle S
Godkin, F Elizabeth
Cornish, Benjamin F
McIlroy, William E
Van Ooteghem, Karen
Wrist Accelerometer Estimates of Physical Activity Intensity During Walking in Older Adults and People Living With Complex Health Conditions: Retrospective Observational Data Analysis Study
title Wrist Accelerometer Estimates of Physical Activity Intensity During Walking in Older Adults and People Living With Complex Health Conditions: Retrospective Observational Data Analysis Study
title_full Wrist Accelerometer Estimates of Physical Activity Intensity During Walking in Older Adults and People Living With Complex Health Conditions: Retrospective Observational Data Analysis Study
title_fullStr Wrist Accelerometer Estimates of Physical Activity Intensity During Walking in Older Adults and People Living With Complex Health Conditions: Retrospective Observational Data Analysis Study
title_full_unstemmed Wrist Accelerometer Estimates of Physical Activity Intensity During Walking in Older Adults and People Living With Complex Health Conditions: Retrospective Observational Data Analysis Study
title_short Wrist Accelerometer Estimates of Physical Activity Intensity During Walking in Older Adults and People Living With Complex Health Conditions: Retrospective Observational Data Analysis Study
title_sort wrist accelerometer estimates of physical activity intensity during walking in older adults and people living with complex health conditions: retrospective observational data analysis study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10131658/
https://www.ncbi.nlm.nih.gov/pubmed/36920452
http://dx.doi.org/10.2196/41685
work_keys_str_mv AT weberkyles wristaccelerometerestimatesofphysicalactivityintensityduringwalkinginolderadultsandpeoplelivingwithcomplexhealthconditionsretrospectiveobservationaldataanalysisstudy
AT godkinfelizabeth wristaccelerometerestimatesofphysicalactivityintensityduringwalkinginolderadultsandpeoplelivingwithcomplexhealthconditionsretrospectiveobservationaldataanalysisstudy
AT cornishbenjaminf wristaccelerometerestimatesofphysicalactivityintensityduringwalkinginolderadultsandpeoplelivingwithcomplexhealthconditionsretrospectiveobservationaldataanalysisstudy
AT mcilroywilliame wristaccelerometerestimatesofphysicalactivityintensityduringwalkinginolderadultsandpeoplelivingwithcomplexhealthconditionsretrospectiveobservationaldataanalysisstudy
AT vanooteghemkaren wristaccelerometerestimatesofphysicalactivityintensityduringwalkinginolderadultsandpeoplelivingwithcomplexhealthconditionsretrospectiveobservationaldataanalysisstudy