Cargando…

The Effectiveness of Wearable Devices Using Artificial Intelligence for Blood Glucose Level Forecasting or Prediction: Systematic Review

BACKGROUND: In 2021 alone, diabetes mellitus, a metabolic disorder primarily characterized by abnormally high blood glucose (BG) levels, affected 537 million people globally, and over 6 million deaths were reported. The use of noninvasive technologies, such as wearable devices (WDs), to regulate and...

Descripción completa

Detalles Bibliográficos
Autores principales: Ahmed, Arfan, Aziz, Sarah, Abd-alrazaq, Alaa, Farooq, Faisal, Househ, Mowafa, Sheikh, Javaid
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10131991/
https://www.ncbi.nlm.nih.gov/pubmed/36917147
http://dx.doi.org/10.2196/40259
_version_ 1785031302262554624
author Ahmed, Arfan
Aziz, Sarah
Abd-alrazaq, Alaa
Farooq, Faisal
Househ, Mowafa
Sheikh, Javaid
author_facet Ahmed, Arfan
Aziz, Sarah
Abd-alrazaq, Alaa
Farooq, Faisal
Househ, Mowafa
Sheikh, Javaid
author_sort Ahmed, Arfan
collection PubMed
description BACKGROUND: In 2021 alone, diabetes mellitus, a metabolic disorder primarily characterized by abnormally high blood glucose (BG) levels, affected 537 million people globally, and over 6 million deaths were reported. The use of noninvasive technologies, such as wearable devices (WDs), to regulate and monitor BG in people with diabetes is a relatively new concept and yet in its infancy. Noninvasive WDs coupled with machine learning (ML) techniques have the potential to understand and conclude meaningful information from the gathered data and provide clinically meaningful advanced analytics for the purpose of forecasting or prediction. OBJECTIVE: The purpose of this study is to provide a systematic review complete with a quality assessment looking at diabetes effectiveness of using artificial intelligence (AI) in WDs for forecasting or predicting BG levels. METHODS: We searched 7 of the most popular bibliographic databases. Two reviewers performed study selection and data extraction independently before cross-checking the extracted data. A narrative approach was used to synthesize the data. Quality assessment was performed using an adapted version of the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. RESULTS: From the initial 3872 studies, the features from 12 studies were reported after filtering according to our predefined inclusion criteria. The reference standard in all studies overall (n=11, 92%) was classified as low, as all ground truths were easily replicable. Since the data input to AI technology was highly standardized and there was no effect of flow or time frame on the final output, both factors were categorized in a low-risk group (n=11, 92%). It was observed that classical ML approaches were deployed by half of the studies, the most popular being ensemble-boosted trees (random forest). The most common evaluation metric used was Clarke grid error (n=7, 58%), followed by root mean square error (n=5, 42%). The wide usage of photoplethysmogram and near-infrared sensors was observed on wrist-worn devices. CONCLUSIONS: This review has provided the most extensive work to date summarizing WDs that use ML for diabetic-related BG level forecasting or prediction. Although current studies are few, this study suggests that the general quality of the studies was considered high, as revealed by the QUADAS-2 assessment tool. Further validation is needed for commercially available devices, but we envisage that WDs in general have the potential to remove the need for invasive devices completely for glucose monitoring in the not-too-distant future. TRIAL REGISTRATION: PROSPERO CRD42022303175; https://tinyurl.com/3n9jaayc
format Online
Article
Text
id pubmed-10131991
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-101319912023-04-27 The Effectiveness of Wearable Devices Using Artificial Intelligence for Blood Glucose Level Forecasting or Prediction: Systematic Review Ahmed, Arfan Aziz, Sarah Abd-alrazaq, Alaa Farooq, Faisal Househ, Mowafa Sheikh, Javaid J Med Internet Res Review BACKGROUND: In 2021 alone, diabetes mellitus, a metabolic disorder primarily characterized by abnormally high blood glucose (BG) levels, affected 537 million people globally, and over 6 million deaths were reported. The use of noninvasive technologies, such as wearable devices (WDs), to regulate and monitor BG in people with diabetes is a relatively new concept and yet in its infancy. Noninvasive WDs coupled with machine learning (ML) techniques have the potential to understand and conclude meaningful information from the gathered data and provide clinically meaningful advanced analytics for the purpose of forecasting or prediction. OBJECTIVE: The purpose of this study is to provide a systematic review complete with a quality assessment looking at diabetes effectiveness of using artificial intelligence (AI) in WDs for forecasting or predicting BG levels. METHODS: We searched 7 of the most popular bibliographic databases. Two reviewers performed study selection and data extraction independently before cross-checking the extracted data. A narrative approach was used to synthesize the data. Quality assessment was performed using an adapted version of the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. RESULTS: From the initial 3872 studies, the features from 12 studies were reported after filtering according to our predefined inclusion criteria. The reference standard in all studies overall (n=11, 92%) was classified as low, as all ground truths were easily replicable. Since the data input to AI technology was highly standardized and there was no effect of flow or time frame on the final output, both factors were categorized in a low-risk group (n=11, 92%). It was observed that classical ML approaches were deployed by half of the studies, the most popular being ensemble-boosted trees (random forest). The most common evaluation metric used was Clarke grid error (n=7, 58%), followed by root mean square error (n=5, 42%). The wide usage of photoplethysmogram and near-infrared sensors was observed on wrist-worn devices. CONCLUSIONS: This review has provided the most extensive work to date summarizing WDs that use ML for diabetic-related BG level forecasting or prediction. Although current studies are few, this study suggests that the general quality of the studies was considered high, as revealed by the QUADAS-2 assessment tool. Further validation is needed for commercially available devices, but we envisage that WDs in general have the potential to remove the need for invasive devices completely for glucose monitoring in the not-too-distant future. TRIAL REGISTRATION: PROSPERO CRD42022303175; https://tinyurl.com/3n9jaayc JMIR Publications 2023-03-14 /pmc/articles/PMC10131991/ /pubmed/36917147 http://dx.doi.org/10.2196/40259 Text en ©Arfan Ahmed, Sarah Aziz, Alaa Abd-alrazaq, Faisal Farooq, Mowafa Househ, Javaid Sheikh. Originally published in the Journal of Medical Internet Research (https://www.jmir.org), 14.03.2023. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on https://www.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Review
Ahmed, Arfan
Aziz, Sarah
Abd-alrazaq, Alaa
Farooq, Faisal
Househ, Mowafa
Sheikh, Javaid
The Effectiveness of Wearable Devices Using Artificial Intelligence for Blood Glucose Level Forecasting or Prediction: Systematic Review
title The Effectiveness of Wearable Devices Using Artificial Intelligence for Blood Glucose Level Forecasting or Prediction: Systematic Review
title_full The Effectiveness of Wearable Devices Using Artificial Intelligence for Blood Glucose Level Forecasting or Prediction: Systematic Review
title_fullStr The Effectiveness of Wearable Devices Using Artificial Intelligence for Blood Glucose Level Forecasting or Prediction: Systematic Review
title_full_unstemmed The Effectiveness of Wearable Devices Using Artificial Intelligence for Blood Glucose Level Forecasting or Prediction: Systematic Review
title_short The Effectiveness of Wearable Devices Using Artificial Intelligence for Blood Glucose Level Forecasting or Prediction: Systematic Review
title_sort effectiveness of wearable devices using artificial intelligence for blood glucose level forecasting or prediction: systematic review
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10131991/
https://www.ncbi.nlm.nih.gov/pubmed/36917147
http://dx.doi.org/10.2196/40259
work_keys_str_mv AT ahmedarfan theeffectivenessofwearabledevicesusingartificialintelligenceforbloodglucoselevelforecastingorpredictionsystematicreview
AT azizsarah theeffectivenessofwearabledevicesusingartificialintelligenceforbloodglucoselevelforecastingorpredictionsystematicreview
AT abdalrazaqalaa theeffectivenessofwearabledevicesusingartificialintelligenceforbloodglucoselevelforecastingorpredictionsystematicreview
AT farooqfaisal theeffectivenessofwearabledevicesusingartificialintelligenceforbloodglucoselevelforecastingorpredictionsystematicreview
AT househmowafa theeffectivenessofwearabledevicesusingartificialintelligenceforbloodglucoselevelforecastingorpredictionsystematicreview
AT sheikhjavaid theeffectivenessofwearabledevicesusingartificialintelligenceforbloodglucoselevelforecastingorpredictionsystematicreview
AT ahmedarfan effectivenessofwearabledevicesusingartificialintelligenceforbloodglucoselevelforecastingorpredictionsystematicreview
AT azizsarah effectivenessofwearabledevicesusingartificialintelligenceforbloodglucoselevelforecastingorpredictionsystematicreview
AT abdalrazaqalaa effectivenessofwearabledevicesusingartificialintelligenceforbloodglucoselevelforecastingorpredictionsystematicreview
AT farooqfaisal effectivenessofwearabledevicesusingartificialintelligenceforbloodglucoselevelforecastingorpredictionsystematicreview
AT househmowafa effectivenessofwearabledevicesusingartificialintelligenceforbloodglucoselevelforecastingorpredictionsystematicreview
AT sheikhjavaid effectivenessofwearabledevicesusingartificialintelligenceforbloodglucoselevelforecastingorpredictionsystematicreview