Cargando…

Intubation characteristics using modified USB videolaryngoscope: A prospective, randomised study

BACKGROUND AND AIMS: Videolaryngoscopes with varying characteristics with regard to angulation of blades and video configurations are now available. However, the contribution of each of these in improving ease of intubation is quite different. We evaluated the role of video camera in the performance...

Descripción completa

Detalles Bibliográficos
Autores principales: Ali, Qazi E., Nisanth, N S, Amir, Syed H., Rahat, Asma
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10132676/
https://www.ncbi.nlm.nih.gov/pubmed/37122934
http://dx.doi.org/10.4103/ija.ija_677_22
_version_ 1785031438429585408
author Ali, Qazi E.
Nisanth, N S
Amir, Syed H.
Rahat, Asma
author_facet Ali, Qazi E.
Nisanth, N S
Amir, Syed H.
Rahat, Asma
author_sort Ali, Qazi E.
collection PubMed
description BACKGROUND AND AIMS: Videolaryngoscopes with varying characteristics with regard to angulation of blades and video configurations are now available. However, the contribution of each of these in improving ease of intubation is quite different. We evaluated the role of video camera in the performance of laryngoscopy by using the universal serial bus (USB) videolaryngoscope in patients with predicted difficult airway. METHODS: Sixty patients in the age group of 25 to 65 years having Mallampati grade III or IV were randomly allocated to two groups. All patients were American Society of Anesthesiologists physical status grade I or II and planned for elective surgical procedure under general anesthesia. USB videolaryngoscope or Macintosh laryngoscope was used for intubation as per group allotted. Comparison of time of endotracheal intubation was our primary outcome measure and it was calculated from the time the laryngoscope tip passes the incisors to the initial appearance of capnography wave. Rate of successful intubation, number of attempts needed for successful tube placement, optimisation manoeuvres used, changes in haemodynamic parameters and airway injuries were evaluated as secondary outcomes. RESULTS: Time for intubation was shorter in the Macintosh group than the USB group (P = 0.024). The incidence of successful intubation was similar in both groups (P = 0.079). USB group required lesser number of attempts for tube placement (P = 0.047). The incidence of airway injuries was similar in both the groups. CONCLUSION: USB videolaryngoscope reduces the number of attempts required for successful endotracheal intubation compared to Macintosh laryngoscope though it increases the time for intubation in patients with predicted difficult airway.
format Online
Article
Text
id pubmed-10132676
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-101326762023-04-27 Intubation characteristics using modified USB videolaryngoscope: A prospective, randomised study Ali, Qazi E. Nisanth, N S Amir, Syed H. Rahat, Asma Indian J Anaesth Original Article BACKGROUND AND AIMS: Videolaryngoscopes with varying characteristics with regard to angulation of blades and video configurations are now available. However, the contribution of each of these in improving ease of intubation is quite different. We evaluated the role of video camera in the performance of laryngoscopy by using the universal serial bus (USB) videolaryngoscope in patients with predicted difficult airway. METHODS: Sixty patients in the age group of 25 to 65 years having Mallampati grade III or IV were randomly allocated to two groups. All patients were American Society of Anesthesiologists physical status grade I or II and planned for elective surgical procedure under general anesthesia. USB videolaryngoscope or Macintosh laryngoscope was used for intubation as per group allotted. Comparison of time of endotracheal intubation was our primary outcome measure and it was calculated from the time the laryngoscope tip passes the incisors to the initial appearance of capnography wave. Rate of successful intubation, number of attempts needed for successful tube placement, optimisation manoeuvres used, changes in haemodynamic parameters and airway injuries were evaluated as secondary outcomes. RESULTS: Time for intubation was shorter in the Macintosh group than the USB group (P = 0.024). The incidence of successful intubation was similar in both groups (P = 0.079). USB group required lesser number of attempts for tube placement (P = 0.047). The incidence of airway injuries was similar in both the groups. CONCLUSION: USB videolaryngoscope reduces the number of attempts required for successful endotracheal intubation compared to Macintosh laryngoscope though it increases the time for intubation in patients with predicted difficult airway. Wolters Kluwer - Medknow 2023-02 2023-02-22 /pmc/articles/PMC10132676/ /pubmed/37122934 http://dx.doi.org/10.4103/ija.ija_677_22 Text en Copyright: © 2023 Indian Journal of Anaesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Ali, Qazi E.
Nisanth, N S
Amir, Syed H.
Rahat, Asma
Intubation characteristics using modified USB videolaryngoscope: A prospective, randomised study
title Intubation characteristics using modified USB videolaryngoscope: A prospective, randomised study
title_full Intubation characteristics using modified USB videolaryngoscope: A prospective, randomised study
title_fullStr Intubation characteristics using modified USB videolaryngoscope: A prospective, randomised study
title_full_unstemmed Intubation characteristics using modified USB videolaryngoscope: A prospective, randomised study
title_short Intubation characteristics using modified USB videolaryngoscope: A prospective, randomised study
title_sort intubation characteristics using modified usb videolaryngoscope: a prospective, randomised study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10132676/
https://www.ncbi.nlm.nih.gov/pubmed/37122934
http://dx.doi.org/10.4103/ija.ija_677_22
work_keys_str_mv AT aliqazie intubationcharacteristicsusingmodifiedusbvideolaryngoscopeaprospectiverandomisedstudy
AT nisanthns intubationcharacteristicsusingmodifiedusbvideolaryngoscopeaprospectiverandomisedstudy
AT amirsyedh intubationcharacteristicsusingmodifiedusbvideolaryngoscopeaprospectiverandomisedstudy
AT rahatasma intubationcharacteristicsusingmodifiedusbvideolaryngoscopeaprospectiverandomisedstudy