Comparison of C-MAC Miller blade video laryngoscope with conventional Miller blade in infants undergoing elective surgery- A prospective randomised trial
BACKGROUND AND AIMS: Endotracheal intubation (ET) in infants is considered a challenging task over the decades. Infants have short safe apnoea time, and this difficulty has been vanquished to some extent by using the videolaryngoscopes (VLs), but there exists a dearth of research particularly in thi...
Autores principales: | Manhas, Samriti, Agrawal, Nidhi, Jain, Swati, Sharma, Ridhima, Choudhary, Ripon |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10132685/ https://www.ncbi.nlm.nih.gov/pubmed/37122941 http://dx.doi.org/10.4103/ija.ija_988_22 |
Ejemplares similares
-
A randomised comparative study of Miller laryngoscope blade versus Oxiport(®) Miller laryngoscope blade for neonatal and infant intubations
por: Dias, Raylene, et al.
Publicado: (2017) -
A randomized comparative evaluation of C-MAC video-laryngoscope with Miller laryngoscope for neonatal endotracheal intubation
por: Goel, Sachin, et al.
Publicado: (2022) -
Comparison of the Success of Two Techniques for the Endotracheal Intubation with C-MAC Video Laryngoscope Miller Blade in Children: A Prospective Randomized Study
por: Sinha, Renu, et al.
Publicado: (2016) -
Evaluation of performance of C-MAC(®) video laryngoscope Miller blade size zero for endotracheal intubation in preterm and ex-preterm infants: A retrospective analysis
por: Sinha, Renu, et al.
Publicado: (2019) -
Comparative evaluation of Airtraq™ optical Laryngoscope and Miller's blade in paediatric patients undergoing elective surgery requiring tracheal intubation: A randomized, controlled trial
por: Das, Bikramjit, et al.
Publicado: (2017)