Rare Intra-Aortic Migration of Temporary Epicardial Pacing Wire
Temporary epicardial pacing wires are used routinely in the postoperative period to prevent brady-arrythmias and maintain hemodynamic condition. Their safety and efficacy have been widely accepted with a low incidence of complications. Complications associated with temporary epicardial pacing wires...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Thieme Medical and Scientific Publishers Pvt. Ltd.
2023
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10132866/ https://www.ncbi.nlm.nih.gov/pubmed/37123590 http://dx.doi.org/10.1055/s-0042-1760284 |
_version_ | 1785031477581316096 |
---|---|
author | Sharma, Arun Arya, Shivali Mahajan, Sachin Bansal, Vidur Singhal, Manphool |
author_facet | Sharma, Arun Arya, Shivali Mahajan, Sachin Bansal, Vidur Singhal, Manphool |
author_sort | Sharma, Arun |
collection | PubMed |
description | Temporary epicardial pacing wires are used routinely in the postoperative period to prevent brady-arrythmias and maintain hemodynamic condition. Their safety and efficacy have been widely accepted with a low incidence of complications. Complications associated with temporary epicardial pacing wires may occur during removal or may be related to retained wires. Migration is one of the well-established but rare complications of retained epicardial pacing wire. Though migrations to various organs have been well documented in the literature, there are only few reports on intra-aortic migration of pacing wires in the postoperative period. Further, it is important for radiologists to know and identify these epicardial pacing wires as they may be associated with complications like superadded infection, migration to surrounding or distant areas, and injury to the heart and vessels. |
format | Online Article Text |
id | pubmed-10132866 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Thieme Medical and Scientific Publishers Pvt. Ltd. |
record_format | MEDLINE/PubMed |
spelling | pubmed-101328662023-04-27 Rare Intra-Aortic Migration of Temporary Epicardial Pacing Wire Sharma, Arun Arya, Shivali Mahajan, Sachin Bansal, Vidur Singhal, Manphool Indian J Radiol Imaging Temporary epicardial pacing wires are used routinely in the postoperative period to prevent brady-arrythmias and maintain hemodynamic condition. Their safety and efficacy have been widely accepted with a low incidence of complications. Complications associated with temporary epicardial pacing wires may occur during removal or may be related to retained wires. Migration is one of the well-established but rare complications of retained epicardial pacing wire. Though migrations to various organs have been well documented in the literature, there are only few reports on intra-aortic migration of pacing wires in the postoperative period. Further, it is important for radiologists to know and identify these epicardial pacing wires as they may be associated with complications like superadded infection, migration to surrounding or distant areas, and injury to the heart and vessels. Thieme Medical and Scientific Publishers Pvt. Ltd. 2023-01-13 /pmc/articles/PMC10132866/ /pubmed/37123590 http://dx.doi.org/10.1055/s-0042-1760284 Text en Indian Radiological Association. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. ( https://creativecommons.org/licenses/by-nc-nd/4.0/ ) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited. |
spellingShingle | Sharma, Arun Arya, Shivali Mahajan, Sachin Bansal, Vidur Singhal, Manphool Rare Intra-Aortic Migration of Temporary Epicardial Pacing Wire |
title | Rare Intra-Aortic Migration of Temporary Epicardial Pacing Wire |
title_full | Rare Intra-Aortic Migration of Temporary Epicardial Pacing Wire |
title_fullStr | Rare Intra-Aortic Migration of Temporary Epicardial Pacing Wire |
title_full_unstemmed | Rare Intra-Aortic Migration of Temporary Epicardial Pacing Wire |
title_short | Rare Intra-Aortic Migration of Temporary Epicardial Pacing Wire |
title_sort | rare intra-aortic migration of temporary epicardial pacing wire |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10132866/ https://www.ncbi.nlm.nih.gov/pubmed/37123590 http://dx.doi.org/10.1055/s-0042-1760284 |
work_keys_str_mv | AT sharmaarun rareintraaorticmigrationoftemporaryepicardialpacingwire AT aryashivali rareintraaorticmigrationoftemporaryepicardialpacingwire AT mahajansachin rareintraaorticmigrationoftemporaryepicardialpacingwire AT bansalvidur rareintraaorticmigrationoftemporaryepicardialpacingwire AT singhalmanphool rareintraaorticmigrationoftemporaryepicardialpacingwire |