Cargando…

Flapless and Conjunctiva-Sparing Technique for Transscleral Fixation of Intraocular Lens to Correct Refractive Errors in Eyes without Adequate Capsular Support

PURPOSE: To evaluate refractive outcomes, intraocular lens (IOL) power calculation, and IOL position following a novel conjunctiva-sparing transscleral fixation technique. METHODS: Forty-one eyes of 40 patients managed with a flapless transscleral-sutured technique were included. Preoperative and po...

Descripción completa

Detalles Bibliográficos
Autores principales: Lou, Wei, Chen, Ziang, Huang, Yang, Jin, Haiying
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10132900/
https://www.ncbi.nlm.nih.gov/pubmed/37124064
http://dx.doi.org/10.1155/2023/4032011
_version_ 1785031485640671232
author Lou, Wei
Chen, Ziang
Huang, Yang
Jin, Haiying
author_facet Lou, Wei
Chen, Ziang
Huang, Yang
Jin, Haiying
author_sort Lou, Wei
collection PubMed
description PURPOSE: To evaluate refractive outcomes, intraocular lens (IOL) power calculation, and IOL position following a novel conjunctiva-sparing transscleral fixation technique. METHODS: Forty-one eyes of 40 patients managed with a flapless transscleral-sutured technique were included. Preoperative and postoperative refractive errors (spherical equivalents, SE) were compared. IOL position was assessed on the Scheimpflug images. IOL power was calculated by SRK/T, Holladay 1, and Hoffer Q formulas. RESULTS: The mean age was 57.39 ± 14.83 years (range: 26 to 79 years), and the mean follow-up was 7.46 ± 6.42 months (range: 1 to 24 months). Surgical indications were aphakia (n = 14), subluxated lenses (n = 3), and IOL dislocation (n = 24). The SE was 4.50 ± 6.38 diopter (D) (range: −3.75 to 13.75 D) preoperatively and −1.68 ± 1.57 D (range: −5.50 to 1.13 D) postoperatively (P < 0.001). The mean tilt angle and decentration were 2.90° ± 1.93° (range: 0.39° to 9.10°) and 0.23 ± 0.19 mm (range: 0.02 to 0.94 mm) vertically, and 1.75° ± 1.41° (range: 0.24° to 7.65°) and 0.18 ± 0.19 mm (range: 0.02 to 1.06 mm) horizontally, which were clinically insignificant. All three IOL formulas produced myopic errors (range: −0.29 to −0.50 D). The SRK/T had the lowest median absolute error (0.55 D), followed by the Holladay 1 (0.70 D) and the Hoffer Q (0.74 D). The three formulas had the same percentage of prediction errors (PEs) within ±0.5 D (43.48%), while the Hoffer Q had the highest percentage of PEs within ±1.0 D (82.61%). CONCLUSION: The present technique can serve as an alternative approach for transscleral IOL fixation and refractive correction in eyes with compromised capsular support, ensuring the stability of IOLs and reasonable IOL power calculation accuracy.
format Online
Article
Text
id pubmed-10132900
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-101329002023-04-27 Flapless and Conjunctiva-Sparing Technique for Transscleral Fixation of Intraocular Lens to Correct Refractive Errors in Eyes without Adequate Capsular Support Lou, Wei Chen, Ziang Huang, Yang Jin, Haiying J Ophthalmol Research Article PURPOSE: To evaluate refractive outcomes, intraocular lens (IOL) power calculation, and IOL position following a novel conjunctiva-sparing transscleral fixation technique. METHODS: Forty-one eyes of 40 patients managed with a flapless transscleral-sutured technique were included. Preoperative and postoperative refractive errors (spherical equivalents, SE) were compared. IOL position was assessed on the Scheimpflug images. IOL power was calculated by SRK/T, Holladay 1, and Hoffer Q formulas. RESULTS: The mean age was 57.39 ± 14.83 years (range: 26 to 79 years), and the mean follow-up was 7.46 ± 6.42 months (range: 1 to 24 months). Surgical indications were aphakia (n = 14), subluxated lenses (n = 3), and IOL dislocation (n = 24). The SE was 4.50 ± 6.38 diopter (D) (range: −3.75 to 13.75 D) preoperatively and −1.68 ± 1.57 D (range: −5.50 to 1.13 D) postoperatively (P < 0.001). The mean tilt angle and decentration were 2.90° ± 1.93° (range: 0.39° to 9.10°) and 0.23 ± 0.19 mm (range: 0.02 to 0.94 mm) vertically, and 1.75° ± 1.41° (range: 0.24° to 7.65°) and 0.18 ± 0.19 mm (range: 0.02 to 1.06 mm) horizontally, which were clinically insignificant. All three IOL formulas produced myopic errors (range: −0.29 to −0.50 D). The SRK/T had the lowest median absolute error (0.55 D), followed by the Holladay 1 (0.70 D) and the Hoffer Q (0.74 D). The three formulas had the same percentage of prediction errors (PEs) within ±0.5 D (43.48%), while the Hoffer Q had the highest percentage of PEs within ±1.0 D (82.61%). CONCLUSION: The present technique can serve as an alternative approach for transscleral IOL fixation and refractive correction in eyes with compromised capsular support, ensuring the stability of IOLs and reasonable IOL power calculation accuracy. Hindawi 2023-04-19 /pmc/articles/PMC10132900/ /pubmed/37124064 http://dx.doi.org/10.1155/2023/4032011 Text en Copyright © 2023 Wei Lou et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Lou, Wei
Chen, Ziang
Huang, Yang
Jin, Haiying
Flapless and Conjunctiva-Sparing Technique for Transscleral Fixation of Intraocular Lens to Correct Refractive Errors in Eyes without Adequate Capsular Support
title Flapless and Conjunctiva-Sparing Technique for Transscleral Fixation of Intraocular Lens to Correct Refractive Errors in Eyes without Adequate Capsular Support
title_full Flapless and Conjunctiva-Sparing Technique for Transscleral Fixation of Intraocular Lens to Correct Refractive Errors in Eyes without Adequate Capsular Support
title_fullStr Flapless and Conjunctiva-Sparing Technique for Transscleral Fixation of Intraocular Lens to Correct Refractive Errors in Eyes without Adequate Capsular Support
title_full_unstemmed Flapless and Conjunctiva-Sparing Technique for Transscleral Fixation of Intraocular Lens to Correct Refractive Errors in Eyes without Adequate Capsular Support
title_short Flapless and Conjunctiva-Sparing Technique for Transscleral Fixation of Intraocular Lens to Correct Refractive Errors in Eyes without Adequate Capsular Support
title_sort flapless and conjunctiva-sparing technique for transscleral fixation of intraocular lens to correct refractive errors in eyes without adequate capsular support
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10132900/
https://www.ncbi.nlm.nih.gov/pubmed/37124064
http://dx.doi.org/10.1155/2023/4032011
work_keys_str_mv AT louwei flaplessandconjunctivasparingtechniquefortransscleralfixationofintraocularlenstocorrectrefractiveerrorsineyeswithoutadequatecapsularsupport
AT chenziang flaplessandconjunctivasparingtechniquefortransscleralfixationofintraocularlenstocorrectrefractiveerrorsineyeswithoutadequatecapsularsupport
AT huangyang flaplessandconjunctivasparingtechniquefortransscleralfixationofintraocularlenstocorrectrefractiveerrorsineyeswithoutadequatecapsularsupport
AT jinhaiying flaplessandconjunctivasparingtechniquefortransscleralfixationofintraocularlenstocorrectrefractiveerrorsineyeswithoutadequatecapsularsupport