Cargando…

Reliability of Retinal Layer Annotation with a Novel, High-Resolution Optical Coherence Tomography Device: A Comparative Study

Optical coherence tomography (OCT) enables in vivo diagnostics of individual retinal layers in the living human eye. However, improved imaging resolution could aid diagnosis and monitoring of retinal diseases and identify potential new imaging biomarkers. The investigational high-resolution OCT plat...

Descripción completa

Detalles Bibliográficos
Autores principales: von der Emde, Leon, Saßmannshausen, Marlene, Morelle, Olivier, Rennen, Geena, Holz, Frank G., Wintergerst, Maximilian W. M., Ach, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10136209/
https://www.ncbi.nlm.nih.gov/pubmed/37106625
http://dx.doi.org/10.3390/bioengineering10040438
_version_ 1785032161637695488
author von der Emde, Leon
Saßmannshausen, Marlene
Morelle, Olivier
Rennen, Geena
Holz, Frank G.
Wintergerst, Maximilian W. M.
Ach, Thomas
author_facet von der Emde, Leon
Saßmannshausen, Marlene
Morelle, Olivier
Rennen, Geena
Holz, Frank G.
Wintergerst, Maximilian W. M.
Ach, Thomas
author_sort von der Emde, Leon
collection PubMed
description Optical coherence tomography (OCT) enables in vivo diagnostics of individual retinal layers in the living human eye. However, improved imaging resolution could aid diagnosis and monitoring of retinal diseases and identify potential new imaging biomarkers. The investigational high-resolution OCT platform (High-Res OCT; 853 nm central wavelength, 3 µm axial-resolution) has an improved axial resolution by shifting the central wavelength and increasing the light source bandwidth compared to a conventional OCT device (880 nm central wavelength, 7 µm axial-resolution). To assess the possible benefit of a higher resolution, we compared the retest reliability of retinal layer annotation from conventional and High-Res OCT, evaluated the use of High-Res OCT in patients with age-related macular degeneration (AMD), and assessed differences of both devices on subjective image quality. Thirty eyes of 30 patients with early/intermediate AMD (iAMD; mean age 75 ± 8 years) and 30 eyes of 30 age-similar subjects without macular changes (62 ± 17 years) underwent identical OCT imaging on both devices. Inter- and intra-reader reliability were analyzed for manual retinal layer annotation using EyeLab. Central OCT B-scans were graded for image quality by two graders and a mean-opinion-score (MOS) was formed and evaluated. Inter- and intra-reader reliability were higher for High-Res OCT (greatest benefit for inter-reader reliability: ganglion cell layer; for intra-reader reliability: retinal nerve fiber layer). High-Res OCT was significantly associated with an improved MOS (MOS 9/8, Z-value = 5.4, p < 0.01) mainly due to improved subjective resolution (9/7, Z-Value 6.2, p < 0.01). The retinal pigment epithelium drusen complex showed a trend towards improved retest reliability in High-Res OCT in iAMD eyes but without statistical significance. Improved axial resolution of the High-Res OCT benefits retest reliability of retinal layer annotation and improves perceived image quality and resolution. Automated image analysis algorithms could also benefit from the increased image resolution.
format Online
Article
Text
id pubmed-10136209
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-101362092023-04-28 Reliability of Retinal Layer Annotation with a Novel, High-Resolution Optical Coherence Tomography Device: A Comparative Study von der Emde, Leon Saßmannshausen, Marlene Morelle, Olivier Rennen, Geena Holz, Frank G. Wintergerst, Maximilian W. M. Ach, Thomas Bioengineering (Basel) Article Optical coherence tomography (OCT) enables in vivo diagnostics of individual retinal layers in the living human eye. However, improved imaging resolution could aid diagnosis and monitoring of retinal diseases and identify potential new imaging biomarkers. The investigational high-resolution OCT platform (High-Res OCT; 853 nm central wavelength, 3 µm axial-resolution) has an improved axial resolution by shifting the central wavelength and increasing the light source bandwidth compared to a conventional OCT device (880 nm central wavelength, 7 µm axial-resolution). To assess the possible benefit of a higher resolution, we compared the retest reliability of retinal layer annotation from conventional and High-Res OCT, evaluated the use of High-Res OCT in patients with age-related macular degeneration (AMD), and assessed differences of both devices on subjective image quality. Thirty eyes of 30 patients with early/intermediate AMD (iAMD; mean age 75 ± 8 years) and 30 eyes of 30 age-similar subjects without macular changes (62 ± 17 years) underwent identical OCT imaging on both devices. Inter- and intra-reader reliability were analyzed for manual retinal layer annotation using EyeLab. Central OCT B-scans were graded for image quality by two graders and a mean-opinion-score (MOS) was formed and evaluated. Inter- and intra-reader reliability were higher for High-Res OCT (greatest benefit for inter-reader reliability: ganglion cell layer; for intra-reader reliability: retinal nerve fiber layer). High-Res OCT was significantly associated with an improved MOS (MOS 9/8, Z-value = 5.4, p < 0.01) mainly due to improved subjective resolution (9/7, Z-Value 6.2, p < 0.01). The retinal pigment epithelium drusen complex showed a trend towards improved retest reliability in High-Res OCT in iAMD eyes but without statistical significance. Improved axial resolution of the High-Res OCT benefits retest reliability of retinal layer annotation and improves perceived image quality and resolution. Automated image analysis algorithms could also benefit from the increased image resolution. MDPI 2023-03-31 /pmc/articles/PMC10136209/ /pubmed/37106625 http://dx.doi.org/10.3390/bioengineering10040438 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
von der Emde, Leon
Saßmannshausen, Marlene
Morelle, Olivier
Rennen, Geena
Holz, Frank G.
Wintergerst, Maximilian W. M.
Ach, Thomas
Reliability of Retinal Layer Annotation with a Novel, High-Resolution Optical Coherence Tomography Device: A Comparative Study
title Reliability of Retinal Layer Annotation with a Novel, High-Resolution Optical Coherence Tomography Device: A Comparative Study
title_full Reliability of Retinal Layer Annotation with a Novel, High-Resolution Optical Coherence Tomography Device: A Comparative Study
title_fullStr Reliability of Retinal Layer Annotation with a Novel, High-Resolution Optical Coherence Tomography Device: A Comparative Study
title_full_unstemmed Reliability of Retinal Layer Annotation with a Novel, High-Resolution Optical Coherence Tomography Device: A Comparative Study
title_short Reliability of Retinal Layer Annotation with a Novel, High-Resolution Optical Coherence Tomography Device: A Comparative Study
title_sort reliability of retinal layer annotation with a novel, high-resolution optical coherence tomography device: a comparative study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10136209/
https://www.ncbi.nlm.nih.gov/pubmed/37106625
http://dx.doi.org/10.3390/bioengineering10040438
work_keys_str_mv AT vonderemdeleon reliabilityofretinallayerannotationwithanovelhighresolutionopticalcoherencetomographydeviceacomparativestudy
AT saßmannshausenmarlene reliabilityofretinallayerannotationwithanovelhighresolutionopticalcoherencetomographydeviceacomparativestudy
AT morelleolivier reliabilityofretinallayerannotationwithanovelhighresolutionopticalcoherencetomographydeviceacomparativestudy
AT rennengeena reliabilityofretinallayerannotationwithanovelhighresolutionopticalcoherencetomographydeviceacomparativestudy
AT holzfrankg reliabilityofretinallayerannotationwithanovelhighresolutionopticalcoherencetomographydeviceacomparativestudy
AT wintergerstmaximilianwm reliabilityofretinallayerannotationwithanovelhighresolutionopticalcoherencetomographydeviceacomparativestudy
AT achthomas reliabilityofretinallayerannotationwithanovelhighresolutionopticalcoherencetomographydeviceacomparativestudy