Cargando…

An Electrochemical o-Phthalaldehyde Sensor Using a Modified Disposable Screen-Printed Electrode with Polyacrylate Hydrogel for Concentration Verification of Clinical Disinfectant

The study proposes an o-phthalaldehyde (OPA) sensor for rapid and reliable detection of OPA in healthcare disinfection practices, based on a hydrogel-modified screen-printed carbon electrode strip. The hydrogel film, which contains glycine and N-acetylcysteine, reacts with OPA to produce a reductive...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Richie L. C., Hsieh, Bo-Chuan, Lin, Jia-Sin, Cheng, Tzong-Jih
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10136433/
https://www.ncbi.nlm.nih.gov/pubmed/37185560
http://dx.doi.org/10.3390/bios13040485
_version_ 1785032216691081216
author Chen, Richie L. C.
Hsieh, Bo-Chuan
Lin, Jia-Sin
Cheng, Tzong-Jih
author_facet Chen, Richie L. C.
Hsieh, Bo-Chuan
Lin, Jia-Sin
Cheng, Tzong-Jih
author_sort Chen, Richie L. C.
collection PubMed
description The study proposes an o-phthalaldehyde (OPA) sensor for rapid and reliable detection of OPA in healthcare disinfection practices, based on a hydrogel-modified screen-printed carbon electrode strip. The hydrogel film, which contains glycine and N-acetylcysteine, reacts with OPA to produce a reductive isoindole derivative. The derivative is then oxidized for OPA determination using cyclic voltammetry. The proposed sensor achieves an optimal detection time of 20–30 s and requires only a small analyte volume of 5 µL. It exhibits good precision (10%) and sensitivity (3.3 μA/cm(2) mM) in a phosphate-buffered solution (pH 7.6), with excellent linearity (R(2) > 0.97) and precision (<3%) in the detection range (0.2–0.6%) required for clinical OPA solutions. Moreover, the sensor demonstrates good concentration verification of Cidex-OPA disinfection in healthcare institutes, with high sensitivity (18.28 μA/cm(2) mM) and precision around the minimum effective concentration (0.3%). Overall, the proposed sensor offers a promising and practical solution for accurate and reliable OPA detection in clinical disinfection practices.
format Online
Article
Text
id pubmed-10136433
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-101364332023-04-28 An Electrochemical o-Phthalaldehyde Sensor Using a Modified Disposable Screen-Printed Electrode with Polyacrylate Hydrogel for Concentration Verification of Clinical Disinfectant Chen, Richie L. C. Hsieh, Bo-Chuan Lin, Jia-Sin Cheng, Tzong-Jih Biosensors (Basel) Article The study proposes an o-phthalaldehyde (OPA) sensor for rapid and reliable detection of OPA in healthcare disinfection practices, based on a hydrogel-modified screen-printed carbon electrode strip. The hydrogel film, which contains glycine and N-acetylcysteine, reacts with OPA to produce a reductive isoindole derivative. The derivative is then oxidized for OPA determination using cyclic voltammetry. The proposed sensor achieves an optimal detection time of 20–30 s and requires only a small analyte volume of 5 µL. It exhibits good precision (10%) and sensitivity (3.3 μA/cm(2) mM) in a phosphate-buffered solution (pH 7.6), with excellent linearity (R(2) > 0.97) and precision (<3%) in the detection range (0.2–0.6%) required for clinical OPA solutions. Moreover, the sensor demonstrates good concentration verification of Cidex-OPA disinfection in healthcare institutes, with high sensitivity (18.28 μA/cm(2) mM) and precision around the minimum effective concentration (0.3%). Overall, the proposed sensor offers a promising and practical solution for accurate and reliable OPA detection in clinical disinfection practices. MDPI 2023-04-17 /pmc/articles/PMC10136433/ /pubmed/37185560 http://dx.doi.org/10.3390/bios13040485 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chen, Richie L. C.
Hsieh, Bo-Chuan
Lin, Jia-Sin
Cheng, Tzong-Jih
An Electrochemical o-Phthalaldehyde Sensor Using a Modified Disposable Screen-Printed Electrode with Polyacrylate Hydrogel for Concentration Verification of Clinical Disinfectant
title An Electrochemical o-Phthalaldehyde Sensor Using a Modified Disposable Screen-Printed Electrode with Polyacrylate Hydrogel for Concentration Verification of Clinical Disinfectant
title_full An Electrochemical o-Phthalaldehyde Sensor Using a Modified Disposable Screen-Printed Electrode with Polyacrylate Hydrogel for Concentration Verification of Clinical Disinfectant
title_fullStr An Electrochemical o-Phthalaldehyde Sensor Using a Modified Disposable Screen-Printed Electrode with Polyacrylate Hydrogel for Concentration Verification of Clinical Disinfectant
title_full_unstemmed An Electrochemical o-Phthalaldehyde Sensor Using a Modified Disposable Screen-Printed Electrode with Polyacrylate Hydrogel for Concentration Verification of Clinical Disinfectant
title_short An Electrochemical o-Phthalaldehyde Sensor Using a Modified Disposable Screen-Printed Electrode with Polyacrylate Hydrogel for Concentration Verification of Clinical Disinfectant
title_sort electrochemical o-phthalaldehyde sensor using a modified disposable screen-printed electrode with polyacrylate hydrogel for concentration verification of clinical disinfectant
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10136433/
https://www.ncbi.nlm.nih.gov/pubmed/37185560
http://dx.doi.org/10.3390/bios13040485
work_keys_str_mv AT chenrichielc anelectrochemicalophthalaldehydesensorusingamodifieddisposablescreenprintedelectrodewithpolyacrylatehydrogelforconcentrationverificationofclinicaldisinfectant
AT hsiehbochuan anelectrochemicalophthalaldehydesensorusingamodifieddisposablescreenprintedelectrodewithpolyacrylatehydrogelforconcentrationverificationofclinicaldisinfectant
AT linjiasin anelectrochemicalophthalaldehydesensorusingamodifieddisposablescreenprintedelectrodewithpolyacrylatehydrogelforconcentrationverificationofclinicaldisinfectant
AT chengtzongjih anelectrochemicalophthalaldehydesensorusingamodifieddisposablescreenprintedelectrodewithpolyacrylatehydrogelforconcentrationverificationofclinicaldisinfectant
AT chenrichielc electrochemicalophthalaldehydesensorusingamodifieddisposablescreenprintedelectrodewithpolyacrylatehydrogelforconcentrationverificationofclinicaldisinfectant
AT hsiehbochuan electrochemicalophthalaldehydesensorusingamodifieddisposablescreenprintedelectrodewithpolyacrylatehydrogelforconcentrationverificationofclinicaldisinfectant
AT linjiasin electrochemicalophthalaldehydesensorusingamodifieddisposablescreenprintedelectrodewithpolyacrylatehydrogelforconcentrationverificationofclinicaldisinfectant
AT chengtzongjih electrochemicalophthalaldehydesensorusingamodifieddisposablescreenprintedelectrodewithpolyacrylatehydrogelforconcentrationverificationofclinicaldisinfectant