Cargando…

Mandibular Reconstruction after Resection of Ameloblastoma by Custom-Made CAD/CAM Mandibular Titanium Prosthesis: Two Case Reports, Finite Element Analysis and Discussion of the Technique

Virtual surgical planning for CAD/CAM mandibular reconstruction by titanium prosthesis was recently reported for resected cases. Even if some advantages are evident, difficulties that may arise for TMJ function after reconstruction originate from prosthesis contamination through oral mucosa dehiscen...

Descripción completa

Detalles Bibliográficos
Autores principales: Cortese, Antonio, Spirito, Francesca, Claudio, Pier Paolo, Lo Muzio, Lorenzo, Ruggiero, Alessandro, Gargiulo, Maurizio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10137091/
https://www.ncbi.nlm.nih.gov/pubmed/37185484
http://dx.doi.org/10.3390/dj11040106
_version_ 1785032375965581312
author Cortese, Antonio
Spirito, Francesca
Claudio, Pier Paolo
Lo Muzio, Lorenzo
Ruggiero, Alessandro
Gargiulo, Maurizio
author_facet Cortese, Antonio
Spirito, Francesca
Claudio, Pier Paolo
Lo Muzio, Lorenzo
Ruggiero, Alessandro
Gargiulo, Maurizio
author_sort Cortese, Antonio
collection PubMed
description Virtual surgical planning for CAD/CAM mandibular reconstruction by titanium prosthesis was recently reported for resected cases. Even if some advantages are evident, difficulties that may arise for TMJ function after reconstruction originate from prosthesis contamination through oral mucosa dehiscence. In these two cases reported of mandibular reconstruction after resection of ameloblastoma by custom-made CAD/CAM titanium prosthesis, the procedures were aimed to preserve the TMJ glenoid cavity and articular disc avoiding functional problems for hemi-mandibular resections that included the condyle (as in case #1) or with condylar preservation (as in case #2) and avoiding intraoral incisions in both cases. The entire surgical planning and prosthetic fabrication were explained with specifications and the sequence of the surgical procedure. Finite elements analysis (FEA) was performed to check the force distribution and efficacy of the prosthetic device (case 1 with hemi-mandibular resection and rehabilitation). Although successful in these two cases, surgical reconstruction of the mandibular defect after resection by a CAD-CAM custom-made prosthesis still shows some drawbacks and failure risks. Several advantages of this technique and the surgical success in these two cases were presented, but limitations and side effects must be considered when cases are selected.
format Online
Article
Text
id pubmed-10137091
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-101370912023-04-28 Mandibular Reconstruction after Resection of Ameloblastoma by Custom-Made CAD/CAM Mandibular Titanium Prosthesis: Two Case Reports, Finite Element Analysis and Discussion of the Technique Cortese, Antonio Spirito, Francesca Claudio, Pier Paolo Lo Muzio, Lorenzo Ruggiero, Alessandro Gargiulo, Maurizio Dent J (Basel) Case Report Virtual surgical planning for CAD/CAM mandibular reconstruction by titanium prosthesis was recently reported for resected cases. Even if some advantages are evident, difficulties that may arise for TMJ function after reconstruction originate from prosthesis contamination through oral mucosa dehiscence. In these two cases reported of mandibular reconstruction after resection of ameloblastoma by custom-made CAD/CAM titanium prosthesis, the procedures were aimed to preserve the TMJ glenoid cavity and articular disc avoiding functional problems for hemi-mandibular resections that included the condyle (as in case #1) or with condylar preservation (as in case #2) and avoiding intraoral incisions in both cases. The entire surgical planning and prosthetic fabrication were explained with specifications and the sequence of the surgical procedure. Finite elements analysis (FEA) was performed to check the force distribution and efficacy of the prosthetic device (case 1 with hemi-mandibular resection and rehabilitation). Although successful in these two cases, surgical reconstruction of the mandibular defect after resection by a CAD-CAM custom-made prosthesis still shows some drawbacks and failure risks. Several advantages of this technique and the surgical success in these two cases were presented, but limitations and side effects must be considered when cases are selected. MDPI 2023-04-20 /pmc/articles/PMC10137091/ /pubmed/37185484 http://dx.doi.org/10.3390/dj11040106 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Case Report
Cortese, Antonio
Spirito, Francesca
Claudio, Pier Paolo
Lo Muzio, Lorenzo
Ruggiero, Alessandro
Gargiulo, Maurizio
Mandibular Reconstruction after Resection of Ameloblastoma by Custom-Made CAD/CAM Mandibular Titanium Prosthesis: Two Case Reports, Finite Element Analysis and Discussion of the Technique
title Mandibular Reconstruction after Resection of Ameloblastoma by Custom-Made CAD/CAM Mandibular Titanium Prosthesis: Two Case Reports, Finite Element Analysis and Discussion of the Technique
title_full Mandibular Reconstruction after Resection of Ameloblastoma by Custom-Made CAD/CAM Mandibular Titanium Prosthesis: Two Case Reports, Finite Element Analysis and Discussion of the Technique
title_fullStr Mandibular Reconstruction after Resection of Ameloblastoma by Custom-Made CAD/CAM Mandibular Titanium Prosthesis: Two Case Reports, Finite Element Analysis and Discussion of the Technique
title_full_unstemmed Mandibular Reconstruction after Resection of Ameloblastoma by Custom-Made CAD/CAM Mandibular Titanium Prosthesis: Two Case Reports, Finite Element Analysis and Discussion of the Technique
title_short Mandibular Reconstruction after Resection of Ameloblastoma by Custom-Made CAD/CAM Mandibular Titanium Prosthesis: Two Case Reports, Finite Element Analysis and Discussion of the Technique
title_sort mandibular reconstruction after resection of ameloblastoma by custom-made cad/cam mandibular titanium prosthesis: two case reports, finite element analysis and discussion of the technique
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10137091/
https://www.ncbi.nlm.nih.gov/pubmed/37185484
http://dx.doi.org/10.3390/dj11040106
work_keys_str_mv AT corteseantonio mandibularreconstructionafterresectionofameloblastomabycustommadecadcammandibulartitaniumprosthesistwocasereportsfiniteelementanalysisanddiscussionofthetechnique
AT spiritofrancesca mandibularreconstructionafterresectionofameloblastomabycustommadecadcammandibulartitaniumprosthesistwocasereportsfiniteelementanalysisanddiscussionofthetechnique
AT claudiopierpaolo mandibularreconstructionafterresectionofameloblastomabycustommadecadcammandibulartitaniumprosthesistwocasereportsfiniteelementanalysisanddiscussionofthetechnique
AT lomuziolorenzo mandibularreconstructionafterresectionofameloblastomabycustommadecadcammandibulartitaniumprosthesistwocasereportsfiniteelementanalysisanddiscussionofthetechnique
AT ruggieroalessandro mandibularreconstructionafterresectionofameloblastomabycustommadecadcammandibulartitaniumprosthesistwocasereportsfiniteelementanalysisanddiscussionofthetechnique
AT gargiulomaurizio mandibularreconstructionafterresectionofameloblastomabycustommadecadcammandibulartitaniumprosthesistwocasereportsfiniteelementanalysisanddiscussionofthetechnique