Response Surface Methodology for Optimization of Hydrogel-Forming Microneedles as Rapid and Efficient Transdermal Microsampling Tools
Microneedles (MNs) have shown a great potential for the microsampling of dermal interstitial fluid (ISF) in a minimally invasive manner for point-of-care testing (POCT). The swelling properties of hydrogel-forming microneedles (MNs) allow for passive extraction of ISF. Surface response approaches, i...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10137625/ https://www.ncbi.nlm.nih.gov/pubmed/37102918 http://dx.doi.org/10.3390/gels9040306 |
_version_ | 1785032511310528512 |
---|---|
author | Leanpolchareanchai, Jiraporn Nuchtavorn, Nantana |
author_facet | Leanpolchareanchai, Jiraporn Nuchtavorn, Nantana |
author_sort | Leanpolchareanchai, Jiraporn |
collection | PubMed |
description | Microneedles (MNs) have shown a great potential for the microsampling of dermal interstitial fluid (ISF) in a minimally invasive manner for point-of-care testing (POCT). The swelling properties of hydrogel-forming microneedles (MNs) allow for passive extraction of ISF. Surface response approaches, including Box-Behnken design (BBD), central composite design (CCD), and optimal discrete design, were employed for the optimization of hydrogel film by studying the effects of independent variables (i.e., the amount of hyaluronic acid, Gantrez(TM) S-97, and pectin) on the swelling property. The optimal discrete model was selected to predict the appropriate variables, due to the good fit of the experimental data and the model validity. The analysis of variance (ANOVA) of the model demonstrated p-value < 0.0001, R(2) = 0.9923, adjusted R(2) = 0.9894, and predicted R(2) = 0.9831. Finally, the predicted film formulation containing 2.75% w/w hyaluronic acid, 1.321% w/w Gantrez(TM) S-97, and 1.246% w/w pectin was used for further fabrication of MNs (525.4 ± 3.8 µm height and 157.4 ± 2.0 µm base width), which possessed 1508.2 ± 66.2% swelling, with 124.6 ± 7.4 µL of collection volume, and could withstand thumb pressure. Moreover, almost 50% of MNs achieved a skin insertion depth of approx. 400 µm, with 71.8 ± 3.2% to 78.3 ± 2.6% recoveries. The developed MNs show a promising prospect in microsample collection, which would be beneficial for POCT. |
format | Online Article Text |
id | pubmed-10137625 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-101376252023-04-28 Response Surface Methodology for Optimization of Hydrogel-Forming Microneedles as Rapid and Efficient Transdermal Microsampling Tools Leanpolchareanchai, Jiraporn Nuchtavorn, Nantana Gels Article Microneedles (MNs) have shown a great potential for the microsampling of dermal interstitial fluid (ISF) in a minimally invasive manner for point-of-care testing (POCT). The swelling properties of hydrogel-forming microneedles (MNs) allow for passive extraction of ISF. Surface response approaches, including Box-Behnken design (BBD), central composite design (CCD), and optimal discrete design, were employed for the optimization of hydrogel film by studying the effects of independent variables (i.e., the amount of hyaluronic acid, Gantrez(TM) S-97, and pectin) on the swelling property. The optimal discrete model was selected to predict the appropriate variables, due to the good fit of the experimental data and the model validity. The analysis of variance (ANOVA) of the model demonstrated p-value < 0.0001, R(2) = 0.9923, adjusted R(2) = 0.9894, and predicted R(2) = 0.9831. Finally, the predicted film formulation containing 2.75% w/w hyaluronic acid, 1.321% w/w Gantrez(TM) S-97, and 1.246% w/w pectin was used for further fabrication of MNs (525.4 ± 3.8 µm height and 157.4 ± 2.0 µm base width), which possessed 1508.2 ± 66.2% swelling, with 124.6 ± 7.4 µL of collection volume, and could withstand thumb pressure. Moreover, almost 50% of MNs achieved a skin insertion depth of approx. 400 µm, with 71.8 ± 3.2% to 78.3 ± 2.6% recoveries. The developed MNs show a promising prospect in microsample collection, which would be beneficial for POCT. MDPI 2023-04-06 /pmc/articles/PMC10137625/ /pubmed/37102918 http://dx.doi.org/10.3390/gels9040306 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Leanpolchareanchai, Jiraporn Nuchtavorn, Nantana Response Surface Methodology for Optimization of Hydrogel-Forming Microneedles as Rapid and Efficient Transdermal Microsampling Tools |
title | Response Surface Methodology for Optimization of Hydrogel-Forming Microneedles as Rapid and Efficient Transdermal Microsampling Tools |
title_full | Response Surface Methodology for Optimization of Hydrogel-Forming Microneedles as Rapid and Efficient Transdermal Microsampling Tools |
title_fullStr | Response Surface Methodology for Optimization of Hydrogel-Forming Microneedles as Rapid and Efficient Transdermal Microsampling Tools |
title_full_unstemmed | Response Surface Methodology for Optimization of Hydrogel-Forming Microneedles as Rapid and Efficient Transdermal Microsampling Tools |
title_short | Response Surface Methodology for Optimization of Hydrogel-Forming Microneedles as Rapid and Efficient Transdermal Microsampling Tools |
title_sort | response surface methodology for optimization of hydrogel-forming microneedles as rapid and efficient transdermal microsampling tools |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10137625/ https://www.ncbi.nlm.nih.gov/pubmed/37102918 http://dx.doi.org/10.3390/gels9040306 |
work_keys_str_mv | AT leanpolchareanchaijiraporn responsesurfacemethodologyforoptimizationofhydrogelformingmicroneedlesasrapidandefficienttransdermalmicrosamplingtools AT nuchtavornnantana responsesurfacemethodologyforoptimizationofhydrogelformingmicroneedlesasrapidandefficienttransdermalmicrosamplingtools |