Cargando…

Aortic Dilatation in Pediatric Patients with Bicuspid Aortic Valve: How the Choice of Nomograms May Change Prevalence

Background: Aortic dilation (AoD) is commonly reported in patients with bicuspid aortic valve (BAV) and has been related to flow abnormalities and genetic predisposition. AoD-related complications are reported to be extremely rare in children. Conversely, an overestimate of AoD related to body size...

Descripción completa

Detalles Bibliográficos
Autores principales: Spaziani, Gaia, Bonanni, Francesca, Girolami, Francesca, Bennati, Elena, Calabri, Giovanni Battista, Di Filippo, Chiara, Porcedda, Giulio, Passantino, Silvia, Nistri, Stefano, Olivotto, Iacopo, Favilli, Silvia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10137718/
https://www.ncbi.nlm.nih.gov/pubmed/37189592
http://dx.doi.org/10.3390/diagnostics13081490
_version_ 1785032534334111744
author Spaziani, Gaia
Bonanni, Francesca
Girolami, Francesca
Bennati, Elena
Calabri, Giovanni Battista
Di Filippo, Chiara
Porcedda, Giulio
Passantino, Silvia
Nistri, Stefano
Olivotto, Iacopo
Favilli, Silvia
author_facet Spaziani, Gaia
Bonanni, Francesca
Girolami, Francesca
Bennati, Elena
Calabri, Giovanni Battista
Di Filippo, Chiara
Porcedda, Giulio
Passantino, Silvia
Nistri, Stefano
Olivotto, Iacopo
Favilli, Silvia
author_sort Spaziani, Gaia
collection PubMed
description Background: Aortic dilation (AoD) is commonly reported in patients with bicuspid aortic valve (BAV) and has been related to flow abnormalities and genetic predisposition. AoD-related complications are reported to be extremely rare in children. Conversely, an overestimate of AoD related to body size may lead to excess diagnoses and negatively impact quality of life and an active lifestyle. In the present study, we compared the diagnosis performance of the newly introduced Q-score (based on a machine-learning algorithm) versus the traditional Z-score in a large consecutive pediatric cohort with BAV. Materials and methods: Prevalence and progression of AoD were evaluated in 281 pediatric patients ages > 5 and < 18 years at first observation, 249 of whom had isolated BAV and 32 had BAV associated with aortic coarctation (CoA–BAV). An additional group of 24 pediatric patients with isolated CoA was considered. Measurements were made at the level of the aortic annulus, Valsalva sinuses, sinotubular aorta, and proximal ascending aorta. Both Z-scores using traditional nomograms and the new Q-score were calculated at baseline and at followup (mean 4.5 years). Results: A dilation of the proximal ascending aorta was suggested by traditional nomograms (Z-score > 2) in 31.2% of patients with isolated BAV and 18.5% with CoA–BAV at baseline and in 40.7% and 33.3%, respectively, at followup. No significant dilation was found in patients with isolated CoA. Using the new Q-score calculator, ascending aorta dilation was detected in 15.4% of patients with BAV and 18.5% with CoA–BAV at baseline and in 15.8% and 3.7%, respectively, at followup. AoD was significantly related to the presence and degree of aortic stenosis (AS) but not to aortic regurgitation (AR). No AoD-related complications occurred during the followup. Conclusions: Our data confirm the presence of ascending aorta dilation in a consistent subgroup of pediatric patients with isolated BAV, with progression during followup, while AoD was less common when CoA was associated with BAV. A positive correlation was found with the prevalence and degree of AS, but not with AR. Finally, the nomograms used may significantly influence the prevalence of AoD, especially in children, with a possible overestimation by traditional nomograms. This concept requires prospective validation in long-term followup.
format Online
Article
Text
id pubmed-10137718
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-101377182023-04-28 Aortic Dilatation in Pediatric Patients with Bicuspid Aortic Valve: How the Choice of Nomograms May Change Prevalence Spaziani, Gaia Bonanni, Francesca Girolami, Francesca Bennati, Elena Calabri, Giovanni Battista Di Filippo, Chiara Porcedda, Giulio Passantino, Silvia Nistri, Stefano Olivotto, Iacopo Favilli, Silvia Diagnostics (Basel) Article Background: Aortic dilation (AoD) is commonly reported in patients with bicuspid aortic valve (BAV) and has been related to flow abnormalities and genetic predisposition. AoD-related complications are reported to be extremely rare in children. Conversely, an overestimate of AoD related to body size may lead to excess diagnoses and negatively impact quality of life and an active lifestyle. In the present study, we compared the diagnosis performance of the newly introduced Q-score (based on a machine-learning algorithm) versus the traditional Z-score in a large consecutive pediatric cohort with BAV. Materials and methods: Prevalence and progression of AoD were evaluated in 281 pediatric patients ages > 5 and < 18 years at first observation, 249 of whom had isolated BAV and 32 had BAV associated with aortic coarctation (CoA–BAV). An additional group of 24 pediatric patients with isolated CoA was considered. Measurements were made at the level of the aortic annulus, Valsalva sinuses, sinotubular aorta, and proximal ascending aorta. Both Z-scores using traditional nomograms and the new Q-score were calculated at baseline and at followup (mean 4.5 years). Results: A dilation of the proximal ascending aorta was suggested by traditional nomograms (Z-score > 2) in 31.2% of patients with isolated BAV and 18.5% with CoA–BAV at baseline and in 40.7% and 33.3%, respectively, at followup. No significant dilation was found in patients with isolated CoA. Using the new Q-score calculator, ascending aorta dilation was detected in 15.4% of patients with BAV and 18.5% with CoA–BAV at baseline and in 15.8% and 3.7%, respectively, at followup. AoD was significantly related to the presence and degree of aortic stenosis (AS) but not to aortic regurgitation (AR). No AoD-related complications occurred during the followup. Conclusions: Our data confirm the presence of ascending aorta dilation in a consistent subgroup of pediatric patients with isolated BAV, with progression during followup, while AoD was less common when CoA was associated with BAV. A positive correlation was found with the prevalence and degree of AS, but not with AR. Finally, the nomograms used may significantly influence the prevalence of AoD, especially in children, with a possible overestimation by traditional nomograms. This concept requires prospective validation in long-term followup. MDPI 2023-04-20 /pmc/articles/PMC10137718/ /pubmed/37189592 http://dx.doi.org/10.3390/diagnostics13081490 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Spaziani, Gaia
Bonanni, Francesca
Girolami, Francesca
Bennati, Elena
Calabri, Giovanni Battista
Di Filippo, Chiara
Porcedda, Giulio
Passantino, Silvia
Nistri, Stefano
Olivotto, Iacopo
Favilli, Silvia
Aortic Dilatation in Pediatric Patients with Bicuspid Aortic Valve: How the Choice of Nomograms May Change Prevalence
title Aortic Dilatation in Pediatric Patients with Bicuspid Aortic Valve: How the Choice of Nomograms May Change Prevalence
title_full Aortic Dilatation in Pediatric Patients with Bicuspid Aortic Valve: How the Choice of Nomograms May Change Prevalence
title_fullStr Aortic Dilatation in Pediatric Patients with Bicuspid Aortic Valve: How the Choice of Nomograms May Change Prevalence
title_full_unstemmed Aortic Dilatation in Pediatric Patients with Bicuspid Aortic Valve: How the Choice of Nomograms May Change Prevalence
title_short Aortic Dilatation in Pediatric Patients with Bicuspid Aortic Valve: How the Choice of Nomograms May Change Prevalence
title_sort aortic dilatation in pediatric patients with bicuspid aortic valve: how the choice of nomograms may change prevalence
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10137718/
https://www.ncbi.nlm.nih.gov/pubmed/37189592
http://dx.doi.org/10.3390/diagnostics13081490
work_keys_str_mv AT spazianigaia aorticdilatationinpediatricpatientswithbicuspidaorticvalvehowthechoiceofnomogramsmaychangeprevalence
AT bonannifrancesca aorticdilatationinpediatricpatientswithbicuspidaorticvalvehowthechoiceofnomogramsmaychangeprevalence
AT girolamifrancesca aorticdilatationinpediatricpatientswithbicuspidaorticvalvehowthechoiceofnomogramsmaychangeprevalence
AT bennatielena aorticdilatationinpediatricpatientswithbicuspidaorticvalvehowthechoiceofnomogramsmaychangeprevalence
AT calabrigiovannibattista aorticdilatationinpediatricpatientswithbicuspidaorticvalvehowthechoiceofnomogramsmaychangeprevalence
AT difilippochiara aorticdilatationinpediatricpatientswithbicuspidaorticvalvehowthechoiceofnomogramsmaychangeprevalence
AT porceddagiulio aorticdilatationinpediatricpatientswithbicuspidaorticvalvehowthechoiceofnomogramsmaychangeprevalence
AT passantinosilvia aorticdilatationinpediatricpatientswithbicuspidaorticvalvehowthechoiceofnomogramsmaychangeprevalence
AT nistristefano aorticdilatationinpediatricpatientswithbicuspidaorticvalvehowthechoiceofnomogramsmaychangeprevalence
AT olivottoiacopo aorticdilatationinpediatricpatientswithbicuspidaorticvalvehowthechoiceofnomogramsmaychangeprevalence
AT favillisilvia aorticdilatationinpediatricpatientswithbicuspidaorticvalvehowthechoiceofnomogramsmaychangeprevalence