Effectiveness of a Self-Decontaminating Coating Containing Usnic Acid in Reducing Environmental Microbial Load in Tertiary-Care Hospitals

Surfaces have been implicated in the transmission of pathogens in hospitals. This study aimed to assess the effectiveness of an usnic-acid-containing self-decontaminating coating in reducing microbial surface contamination in tertiary-care hospitals. Samples were collected from surfaces 9 days befor...

Descripción completa

Detalles Bibliográficos
Autores principales: Maltezou, Helena C., Papamichalopoulos, Nikolaos, Horefti, Elina, Tseroni, Maria, Karapanou, Amalia, Gamaletsou, Maria N., Veneti, Lamprini, Ioannidis, Anastasios, Panagiotou, Marina, Dimitroulia, Evangelia, Vasilogiannakopoulos, Antonios, Angelakis, Emmanouil, Chatzipanagiotou, Stylianos, Sipsas, Nikolaos V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10138069/
https://www.ncbi.nlm.nih.gov/pubmed/37107716
http://dx.doi.org/10.3390/ijerph20085434
Descripción
Sumario:Surfaces have been implicated in the transmission of pathogens in hospitals. This study aimed to assess the effectiveness of an usnic-acid-containing self-decontaminating coating in reducing microbial surface contamination in tertiary-care hospitals. Samples were collected from surfaces 9 days before coating application, and 3, 10, and 21 days after its application (phases 1, 2, 3, and 4, respectively). Samples were tested for bacteria, fungi, and SARS-CoV2. In phase 1, 53/69 (76.8%) samples tested positive for bacteria, 9/69 (13.0%) for fungi, and 10/139 (7.2%) for SARS-CoV-2. In phase 2, 4/69 (5.8%) samples tested positive for bacteria, while 69 and 139 samples were negative for fungi and SARS-CoV-2, respectively. In phase 3, 3/69 (4.3%) samples were positive for bacteria, 1/139 (0.7%) samples tested positive for SARS-CoV-2, while 69 samples were negative for fungi. In phase 4, 1/69 (1.4%) tested positive for bacteria, while no fungus or SARS-CoV-2 were detected. After the coating was applied, the bacterial load was reduced by 87% in phase 2 (RR = 0.132; 95% CI: 0.108–0.162); 99% in phase 3 (RR = 0.006; 95% CI: 0.003–0.015); and 100% in phase 4 (RR = 0.001; 95% CI: 0.000–0.009). These data indicate that the usnic-acid-containing coating was effective in eliminating bacterial, fungal, and SARS-CoV-2 contamination on surfaces in hospitals.Our findings support the benefit ofan usnic-acid-containing coating in reducing the microbial load on healthcare surfaces.