Cargando…

A Three-Dimensional (3D) Evaluation Unveiling if the Anterior Mandible Is Truly a Safe Zone for Implant Placement

Background Dental implants are increasingly being used in the rehabilitation of the edentulous areas in the maxilla and mandible. The anterior mandible is considered a safe zone for implant placement, but clinicians often find it challenging to control bleeding in this area. This is due to the prese...

Descripción completa

Detalles Bibliográficos
Autores principales: Vyas, Rutvi, Tadinada, Aditya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10139677/
https://www.ncbi.nlm.nih.gov/pubmed/37122981
http://dx.doi.org/10.7759/cureus.38084
_version_ 1785032997647417344
author Vyas, Rutvi
Tadinada, Aditya
author_facet Vyas, Rutvi
Tadinada, Aditya
author_sort Vyas, Rutvi
collection PubMed
description Background Dental implants are increasingly being used in the rehabilitation of the edentulous areas in the maxilla and mandible. The anterior mandible is considered a safe zone for implant placement, but clinicians often find it challenging to control bleeding in this area. This is due to the presence of the sublingual artery, which can be of varying dimensions and can cause severe bleeding. This can be of higher significance in patients with high or uncontrolled blood pressure and in patients on blood thinners like Aspirin or Coumadin where establishing a clot can be difficult. With newer guidelines recommending that medication be discontinued only a few hours before surgery and that bleeding be managed locally, this issue has become even more challenging. With three-dimensional (3D) imaging using cone beam computed tomography (CBCT) becoming more common for implant planning, the presence of the sublingual artery can be evaluated and incorporated into the treatment plan. The objective of this study is to evaluate the 3D location of the sublingual artery in the edentulous anterior mandible of CBCT scans of patients referred for dental implant therapy. Methodology A total of 50 de-identified CBCT scans with an edentulous anterior mandible referred for dental implant therapy were evaluated for this study. Cross-sectional images were generated using a CBCT reconstruction program INVIVO-5 (Anatomage, San Jose, CA, USA). After the sublingual artery was localized, measurement was conducted from a standardized point on the alveolar crest to the artery’s entry point on the lingual aspect. Measurements were also obtained from the terminal point of the artery’s course to the buccal cortical plate. Alveolar crest can either resorb or be subjected to alveoloplasty during implant placement, similar measurements were also done from a standardized point on the inferior cortical border of the mandible to the artery’s entry points on the lingual aspect. Two oral and maxillofacial radiologists conducted all measurements. Results It was found that the median value of the sublingual artery from the alveolar crest to the level of entry (V1) was 6.78, the vertical measurement of the artery coursing into the alveolar bone was ~4.03 mm (V2), the vertical measurement of the artery’s position within the alveolar bone at the terminal point form the crest was ~11.71 (V3), and the inferior vertical measurement from the course of the artery to the inferior border of the mandible was 9.60 mm. The artery extended about ~8.3 mm within the alveolar bone from the lingual cortex (H1), and the artery was located about 4.97 mm away from the buccal cortex (H2). Cronbach’s Alpha test showed high interoperator reliability.  Conclusions In this retrospective study, the sublingual artery was noted to be at a critical location in the potential implant site. A site-specific evaluation using CBCT can help in localizing and avoiding perforation of the sublingual artery.
format Online
Article
Text
id pubmed-10139677
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-101396772023-04-28 A Three-Dimensional (3D) Evaluation Unveiling if the Anterior Mandible Is Truly a Safe Zone for Implant Placement Vyas, Rutvi Tadinada, Aditya Cureus Anatomy Background Dental implants are increasingly being used in the rehabilitation of the edentulous areas in the maxilla and mandible. The anterior mandible is considered a safe zone for implant placement, but clinicians often find it challenging to control bleeding in this area. This is due to the presence of the sublingual artery, which can be of varying dimensions and can cause severe bleeding. This can be of higher significance in patients with high or uncontrolled blood pressure and in patients on blood thinners like Aspirin or Coumadin where establishing a clot can be difficult. With newer guidelines recommending that medication be discontinued only a few hours before surgery and that bleeding be managed locally, this issue has become even more challenging. With three-dimensional (3D) imaging using cone beam computed tomography (CBCT) becoming more common for implant planning, the presence of the sublingual artery can be evaluated and incorporated into the treatment plan. The objective of this study is to evaluate the 3D location of the sublingual artery in the edentulous anterior mandible of CBCT scans of patients referred for dental implant therapy. Methodology A total of 50 de-identified CBCT scans with an edentulous anterior mandible referred for dental implant therapy were evaluated for this study. Cross-sectional images were generated using a CBCT reconstruction program INVIVO-5 (Anatomage, San Jose, CA, USA). After the sublingual artery was localized, measurement was conducted from a standardized point on the alveolar crest to the artery’s entry point on the lingual aspect. Measurements were also obtained from the terminal point of the artery’s course to the buccal cortical plate. Alveolar crest can either resorb or be subjected to alveoloplasty during implant placement, similar measurements were also done from a standardized point on the inferior cortical border of the mandible to the artery’s entry points on the lingual aspect. Two oral and maxillofacial radiologists conducted all measurements. Results It was found that the median value of the sublingual artery from the alveolar crest to the level of entry (V1) was 6.78, the vertical measurement of the artery coursing into the alveolar bone was ~4.03 mm (V2), the vertical measurement of the artery’s position within the alveolar bone at the terminal point form the crest was ~11.71 (V3), and the inferior vertical measurement from the course of the artery to the inferior border of the mandible was 9.60 mm. The artery extended about ~8.3 mm within the alveolar bone from the lingual cortex (H1), and the artery was located about 4.97 mm away from the buccal cortex (H2). Cronbach’s Alpha test showed high interoperator reliability.  Conclusions In this retrospective study, the sublingual artery was noted to be at a critical location in the potential implant site. A site-specific evaluation using CBCT can help in localizing and avoiding perforation of the sublingual artery. Cureus 2023-04-24 /pmc/articles/PMC10139677/ /pubmed/37122981 http://dx.doi.org/10.7759/cureus.38084 Text en Copyright © 2023, Vyas et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Anatomy
Vyas, Rutvi
Tadinada, Aditya
A Three-Dimensional (3D) Evaluation Unveiling if the Anterior Mandible Is Truly a Safe Zone for Implant Placement
title A Three-Dimensional (3D) Evaluation Unveiling if the Anterior Mandible Is Truly a Safe Zone for Implant Placement
title_full A Three-Dimensional (3D) Evaluation Unveiling if the Anterior Mandible Is Truly a Safe Zone for Implant Placement
title_fullStr A Three-Dimensional (3D) Evaluation Unveiling if the Anterior Mandible Is Truly a Safe Zone for Implant Placement
title_full_unstemmed A Three-Dimensional (3D) Evaluation Unveiling if the Anterior Mandible Is Truly a Safe Zone for Implant Placement
title_short A Three-Dimensional (3D) Evaluation Unveiling if the Anterior Mandible Is Truly a Safe Zone for Implant Placement
title_sort three-dimensional (3d) evaluation unveiling if the anterior mandible is truly a safe zone for implant placement
topic Anatomy
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10139677/
https://www.ncbi.nlm.nih.gov/pubmed/37122981
http://dx.doi.org/10.7759/cureus.38084
work_keys_str_mv AT vyasrutvi athreedimensional3devaluationunveilingiftheanteriormandibleistrulyasafezoneforimplantplacement
AT tadinadaaditya athreedimensional3devaluationunveilingiftheanteriormandibleistrulyasafezoneforimplantplacement
AT vyasrutvi threedimensional3devaluationunveilingiftheanteriormandibleistrulyasafezoneforimplantplacement
AT tadinadaaditya threedimensional3devaluationunveilingiftheanteriormandibleistrulyasafezoneforimplantplacement