Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity
Vibratory stimulation may improve post-stroke symptoms such as spasticity; however, current studies are limited by the large, clinic-based apparatus used to apply this stimulation. A wearable device could provide vibratory stimulation in a mobile form, enabling further study of this technique. An in...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10139869/ https://www.ncbi.nlm.nih.gov/pubmed/35552152 http://dx.doi.org/10.1109/TNSRE.2022.3174808 |
_version_ | 1785033041664540672 |
---|---|
author | Seim, Caitlyn E. Ritter, Brandon Starner, Thad E. Flavin, Kara Lansberg, Maarten G. Okamura, Allison M. |
author_facet | Seim, Caitlyn E. Ritter, Brandon Starner, Thad E. Flavin, Kara Lansberg, Maarten G. Okamura, Allison M. |
author_sort | Seim, Caitlyn E. |
collection | PubMed |
description | Vibratory stimulation may improve post-stroke symptoms such as spasticity; however, current studies are limited by the large, clinic-based apparatus used to apply this stimulation. A wearable device could provide vibratory stimulation in a mobile form, enabling further study of this technique. An initial device, the vibrotactile stimulation (VTS) Glove, was deployed in an eight-week clinical study in which sixteen individuals with stroke used the device for several hours daily. Participants reported wearing the glove during activities such as church, social events, and dining out. However, 69% of participants struggled to extend or insert their fingers to don the device. In a follow-up study, eight individuals with stroke evaluated new VTS device prototypes in a three-round iterative design study with the aims of creating the next generation of VTS devices and understanding features that influence interaction with a wearable device by individuals with impaired upper-limb function. Interviews and interaction tasks were used to define actionable design revisions between each round of evaluation. Our analysis identified six new themes from participants regarding device designs: hand supination is challenging, separate finger attachments inhibit fit and use, fingers may be flexed or open, fabric coverage impacts comfort, a reduced concern for social comfort, and the affected hand is infrequently used. Straps that wrap around the arm and fixtures on the anterior arm were other challenging features. We discuss potential accommodations for these challenges, as well as social comfort. New VTS device designs are presented and were donned in an average time of 48 seconds. |
format | Online Article Text |
id | pubmed-10139869 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
record_format | MEDLINE/PubMed |
spelling | pubmed-101398692023-04-28 Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity Seim, Caitlyn E. Ritter, Brandon Starner, Thad E. Flavin, Kara Lansberg, Maarten G. Okamura, Allison M. IEEE Trans Neural Syst Rehabil Eng Article Vibratory stimulation may improve post-stroke symptoms such as spasticity; however, current studies are limited by the large, clinic-based apparatus used to apply this stimulation. A wearable device could provide vibratory stimulation in a mobile form, enabling further study of this technique. An initial device, the vibrotactile stimulation (VTS) Glove, was deployed in an eight-week clinical study in which sixteen individuals with stroke used the device for several hours daily. Participants reported wearing the glove during activities such as church, social events, and dining out. However, 69% of participants struggled to extend or insert their fingers to don the device. In a follow-up study, eight individuals with stroke evaluated new VTS device prototypes in a three-round iterative design study with the aims of creating the next generation of VTS devices and understanding features that influence interaction with a wearable device by individuals with impaired upper-limb function. Interviews and interaction tasks were used to define actionable design revisions between each round of evaluation. Our analysis identified six new themes from participants regarding device designs: hand supination is challenging, separate finger attachments inhibit fit and use, fingers may be flexed or open, fabric coverage impacts comfort, a reduced concern for social comfort, and the affected hand is infrequently used. Straps that wrap around the arm and fixtures on the anterior arm were other challenging features. We discuss potential accommodations for these challenges, as well as social comfort. New VTS device designs are presented and were donned in an average time of 48 seconds. 2022 2022-05-17 /pmc/articles/PMC10139869/ /pubmed/35552152 http://dx.doi.org/10.1109/TNSRE.2022.3174808 Text en https://creativecommons.org/licenses/by/4.0/This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Seim, Caitlyn E. Ritter, Brandon Starner, Thad E. Flavin, Kara Lansberg, Maarten G. Okamura, Allison M. Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity |
title | Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity |
title_full | Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity |
title_fullStr | Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity |
title_full_unstemmed | Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity |
title_short | Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity |
title_sort | design of a wearable vibrotactile stimulation device for individuals with upper-limb hemiparesis and spasticity |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10139869/ https://www.ncbi.nlm.nih.gov/pubmed/35552152 http://dx.doi.org/10.1109/TNSRE.2022.3174808 |
work_keys_str_mv | AT seimcaitlyne designofawearablevibrotactilestimulationdeviceforindividualswithupperlimbhemiparesisandspasticity AT ritterbrandon designofawearablevibrotactilestimulationdeviceforindividualswithupperlimbhemiparesisandspasticity AT starnerthade designofawearablevibrotactilestimulationdeviceforindividualswithupperlimbhemiparesisandspasticity AT flavinkara designofawearablevibrotactilestimulationdeviceforindividualswithupperlimbhemiparesisandspasticity AT lansbergmaarteng designofawearablevibrotactilestimulationdeviceforindividualswithupperlimbhemiparesisandspasticity AT okamuraallisonm designofawearablevibrotactilestimulationdeviceforindividualswithupperlimbhemiparesisandspasticity |