Cargando…

Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity

Vibratory stimulation may improve post-stroke symptoms such as spasticity; however, current studies are limited by the large, clinic-based apparatus used to apply this stimulation. A wearable device could provide vibratory stimulation in a mobile form, enabling further study of this technique. An in...

Descripción completa

Detalles Bibliográficos
Autores principales: Seim, Caitlyn E., Ritter, Brandon, Starner, Thad E., Flavin, Kara, Lansberg, Maarten G., Okamura, Allison M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10139869/
https://www.ncbi.nlm.nih.gov/pubmed/35552152
http://dx.doi.org/10.1109/TNSRE.2022.3174808
_version_ 1785033041664540672
author Seim, Caitlyn E.
Ritter, Brandon
Starner, Thad E.
Flavin, Kara
Lansberg, Maarten G.
Okamura, Allison M.
author_facet Seim, Caitlyn E.
Ritter, Brandon
Starner, Thad E.
Flavin, Kara
Lansberg, Maarten G.
Okamura, Allison M.
author_sort Seim, Caitlyn E.
collection PubMed
description Vibratory stimulation may improve post-stroke symptoms such as spasticity; however, current studies are limited by the large, clinic-based apparatus used to apply this stimulation. A wearable device could provide vibratory stimulation in a mobile form, enabling further study of this technique. An initial device, the vibrotactile stimulation (VTS) Glove, was deployed in an eight-week clinical study in which sixteen individuals with stroke used the device for several hours daily. Participants reported wearing the glove during activities such as church, social events, and dining out. However, 69% of participants struggled to extend or insert their fingers to don the device. In a follow-up study, eight individuals with stroke evaluated new VTS device prototypes in a three-round iterative design study with the aims of creating the next generation of VTS devices and understanding features that influence interaction with a wearable device by individuals with impaired upper-limb function. Interviews and interaction tasks were used to define actionable design revisions between each round of evaluation. Our analysis identified six new themes from participants regarding device designs: hand supination is challenging, separate finger attachments inhibit fit and use, fingers may be flexed or open, fabric coverage impacts comfort, a reduced concern for social comfort, and the affected hand is infrequently used. Straps that wrap around the arm and fixtures on the anterior arm were other challenging features. We discuss potential accommodations for these challenges, as well as social comfort. New VTS device designs are presented and were donned in an average time of 48 seconds.
format Online
Article
Text
id pubmed-10139869
institution National Center for Biotechnology Information
language English
publishDate 2022
record_format MEDLINE/PubMed
spelling pubmed-101398692023-04-28 Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity Seim, Caitlyn E. Ritter, Brandon Starner, Thad E. Flavin, Kara Lansberg, Maarten G. Okamura, Allison M. IEEE Trans Neural Syst Rehabil Eng Article Vibratory stimulation may improve post-stroke symptoms such as spasticity; however, current studies are limited by the large, clinic-based apparatus used to apply this stimulation. A wearable device could provide vibratory stimulation in a mobile form, enabling further study of this technique. An initial device, the vibrotactile stimulation (VTS) Glove, was deployed in an eight-week clinical study in which sixteen individuals with stroke used the device for several hours daily. Participants reported wearing the glove during activities such as church, social events, and dining out. However, 69% of participants struggled to extend or insert their fingers to don the device. In a follow-up study, eight individuals with stroke evaluated new VTS device prototypes in a three-round iterative design study with the aims of creating the next generation of VTS devices and understanding features that influence interaction with a wearable device by individuals with impaired upper-limb function. Interviews and interaction tasks were used to define actionable design revisions between each round of evaluation. Our analysis identified six new themes from participants regarding device designs: hand supination is challenging, separate finger attachments inhibit fit and use, fingers may be flexed or open, fabric coverage impacts comfort, a reduced concern for social comfort, and the affected hand is infrequently used. Straps that wrap around the arm and fixtures on the anterior arm were other challenging features. We discuss potential accommodations for these challenges, as well as social comfort. New VTS device designs are presented and were donned in an average time of 48 seconds. 2022 2022-05-17 /pmc/articles/PMC10139869/ /pubmed/35552152 http://dx.doi.org/10.1109/TNSRE.2022.3174808 Text en https://creativecommons.org/licenses/by/4.0/This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Seim, Caitlyn E.
Ritter, Brandon
Starner, Thad E.
Flavin, Kara
Lansberg, Maarten G.
Okamura, Allison M.
Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity
title Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity
title_full Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity
title_fullStr Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity
title_full_unstemmed Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity
title_short Design of a Wearable Vibrotactile Stimulation Device for Individuals With Upper-Limb Hemiparesis and Spasticity
title_sort design of a wearable vibrotactile stimulation device for individuals with upper-limb hemiparesis and spasticity
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10139869/
https://www.ncbi.nlm.nih.gov/pubmed/35552152
http://dx.doi.org/10.1109/TNSRE.2022.3174808
work_keys_str_mv AT seimcaitlyne designofawearablevibrotactilestimulationdeviceforindividualswithupperlimbhemiparesisandspasticity
AT ritterbrandon designofawearablevibrotactilestimulationdeviceforindividualswithupperlimbhemiparesisandspasticity
AT starnerthade designofawearablevibrotactilestimulationdeviceforindividualswithupperlimbhemiparesisandspasticity
AT flavinkara designofawearablevibrotactilestimulationdeviceforindividualswithupperlimbhemiparesisandspasticity
AT lansbergmaarteng designofawearablevibrotactilestimulationdeviceforindividualswithupperlimbhemiparesisandspasticity
AT okamuraallisonm designofawearablevibrotactilestimulationdeviceforindividualswithupperlimbhemiparesisandspasticity