Cargando…
Robot-Assisted Epiretinal Membrane Peeling: A Prospective Assessment of Pre- and Intra-Operative Times and of Surgeons’ Subjective Perceptions
Purpose: The Preceyes Surgical System (PSS) is a robotic assistive device that may enhance surgical precision. This study assessed pre- and intra-operative times and surgeons’ perceptions of robot-assisted epiretinal membrane peeling (RA-MP). Methods: We analyzed the time requirement of three main t...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10141075/ https://www.ncbi.nlm.nih.gov/pubmed/37109104 http://dx.doi.org/10.3390/jcm12082768 |
_version_ | 1785033305801883648 |
---|---|
author | Turgut, Ferhat Somfai, Gábor Márk Heussen, Florian M. Eberle, Alexander de Smet, Marc D. Becker, Matthias D. |
author_facet | Turgut, Ferhat Somfai, Gábor Márk Heussen, Florian M. Eberle, Alexander de Smet, Marc D. Becker, Matthias D. |
author_sort | Turgut, Ferhat |
collection | PubMed |
description | Purpose: The Preceyes Surgical System (PSS) is a robotic assistive device that may enhance surgical precision. This study assessed pre- and intra-operative times and surgeons’ perceptions of robot-assisted epiretinal membrane peeling (RA-MP). Methods: We analyzed the time requirement of three main tasks: the preparation of the PSS (I), patient preparation (II), and surgery (III). Following surgery, the surgeons were asked questions about their experience. Results: RA-MP was performed in nine eyes of nine patients. Task I required an average time of 12.3 min, initially taking 15 min but decreasing to 6 min in the last surgery. Task II showed a mean time of 47.2 (range of 36–65) min. Task III had a mean time of 72.4 (range of 57–100) min. A mean time of 27.9 (range of 9–46) min was necessary for RA-MP. The responses to the questionnaire revealed a trend towards increasing ease and reduced stress as familiarity with the PSS increased. Conclusions: A substantial reduction in pre- and intra-operative times, decreasing to a total of 115 min, was demonstrated. RA-MP was positively anticipated by the surgeons and led to no hand or arm strain while being more complex than manual MP. |
format | Online Article Text |
id | pubmed-10141075 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-101410752023-04-29 Robot-Assisted Epiretinal Membrane Peeling: A Prospective Assessment of Pre- and Intra-Operative Times and of Surgeons’ Subjective Perceptions Turgut, Ferhat Somfai, Gábor Márk Heussen, Florian M. Eberle, Alexander de Smet, Marc D. Becker, Matthias D. J Clin Med Article Purpose: The Preceyes Surgical System (PSS) is a robotic assistive device that may enhance surgical precision. This study assessed pre- and intra-operative times and surgeons’ perceptions of robot-assisted epiretinal membrane peeling (RA-MP). Methods: We analyzed the time requirement of three main tasks: the preparation of the PSS (I), patient preparation (II), and surgery (III). Following surgery, the surgeons were asked questions about their experience. Results: RA-MP was performed in nine eyes of nine patients. Task I required an average time of 12.3 min, initially taking 15 min but decreasing to 6 min in the last surgery. Task II showed a mean time of 47.2 (range of 36–65) min. Task III had a mean time of 72.4 (range of 57–100) min. A mean time of 27.9 (range of 9–46) min was necessary for RA-MP. The responses to the questionnaire revealed a trend towards increasing ease and reduced stress as familiarity with the PSS increased. Conclusions: A substantial reduction in pre- and intra-operative times, decreasing to a total of 115 min, was demonstrated. RA-MP was positively anticipated by the surgeons and led to no hand or arm strain while being more complex than manual MP. MDPI 2023-04-07 /pmc/articles/PMC10141075/ /pubmed/37109104 http://dx.doi.org/10.3390/jcm12082768 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Turgut, Ferhat Somfai, Gábor Márk Heussen, Florian M. Eberle, Alexander de Smet, Marc D. Becker, Matthias D. Robot-Assisted Epiretinal Membrane Peeling: A Prospective Assessment of Pre- and Intra-Operative Times and of Surgeons’ Subjective Perceptions |
title | Robot-Assisted Epiretinal Membrane Peeling: A Prospective Assessment of Pre- and Intra-Operative Times and of Surgeons’ Subjective Perceptions |
title_full | Robot-Assisted Epiretinal Membrane Peeling: A Prospective Assessment of Pre- and Intra-Operative Times and of Surgeons’ Subjective Perceptions |
title_fullStr | Robot-Assisted Epiretinal Membrane Peeling: A Prospective Assessment of Pre- and Intra-Operative Times and of Surgeons’ Subjective Perceptions |
title_full_unstemmed | Robot-Assisted Epiretinal Membrane Peeling: A Prospective Assessment of Pre- and Intra-Operative Times and of Surgeons’ Subjective Perceptions |
title_short | Robot-Assisted Epiretinal Membrane Peeling: A Prospective Assessment of Pre- and Intra-Operative Times and of Surgeons’ Subjective Perceptions |
title_sort | robot-assisted epiretinal membrane peeling: a prospective assessment of pre- and intra-operative times and of surgeons’ subjective perceptions |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10141075/ https://www.ncbi.nlm.nih.gov/pubmed/37109104 http://dx.doi.org/10.3390/jcm12082768 |
work_keys_str_mv | AT turgutferhat robotassistedepiretinalmembranepeelingaprospectiveassessmentofpreandintraoperativetimesandofsurgeonssubjectiveperceptions AT somfaigabormark robotassistedepiretinalmembranepeelingaprospectiveassessmentofpreandintraoperativetimesandofsurgeonssubjectiveperceptions AT heussenflorianm robotassistedepiretinalmembranepeelingaprospectiveassessmentofpreandintraoperativetimesandofsurgeonssubjectiveperceptions AT eberlealexander robotassistedepiretinalmembranepeelingaprospectiveassessmentofpreandintraoperativetimesandofsurgeonssubjectiveperceptions AT desmetmarcd robotassistedepiretinalmembranepeelingaprospectiveassessmentofpreandintraoperativetimesandofsurgeonssubjectiveperceptions AT beckermatthiasd robotassistedepiretinalmembranepeelingaprospectiveassessmentofpreandintraoperativetimesandofsurgeonssubjectiveperceptions |