Potential Use of Wearable Inertial Sensors to Assess and Train Deep Cervical Flexors: A Feasibility Study with Real Time Synchronization of Kinematic and Pressure Data during the Craniocervical Flexion Test

The aim of the study was to develop a novel real-time, computer-based synchronization system to continuously record pressure and craniocervical flexion ROM (range of motion) during the CCFT (craniocervical flexion test) in order to assess its feasibility for measuring and discriminating the values o...

Descripción completa

Detalles Bibliográficos
Autores principales: Bocos-Corredor, Elena, Pérez-Fernández, Tomás, Perez-Dominguez, Raquel, Liébana, Sonia, Armijo-Olivo, Susan, Raya, Rafael, Martin-Pintado-Zugasti, Aitor
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10141233/
https://www.ncbi.nlm.nih.gov/pubmed/37112252
http://dx.doi.org/10.3390/s23083911
_version_ 1785033344031916032
author Bocos-Corredor, Elena
Pérez-Fernández, Tomás
Perez-Dominguez, Raquel
Liébana, Sonia
Armijo-Olivo, Susan
Raya, Rafael
Martin-Pintado-Zugasti, Aitor
author_facet Bocos-Corredor, Elena
Pérez-Fernández, Tomás
Perez-Dominguez, Raquel
Liébana, Sonia
Armijo-Olivo, Susan
Raya, Rafael
Martin-Pintado-Zugasti, Aitor
author_sort Bocos-Corredor, Elena
collection PubMed
description The aim of the study was to develop a novel real-time, computer-based synchronization system to continuously record pressure and craniocervical flexion ROM (range of motion) during the CCFT (craniocervical flexion test) in order to assess its feasibility for measuring and discriminating the values of ROM between different pressure levels. This was a descriptive, observational, cross-sectional, feasibility study. Participants performed a full-range craniocervical flexion and the CCFT. During the CCFT, a pressure sensor and a wireless inertial sensor simultaneously registered data of pressure and ROM. A web application was developed using HTML and NodeJS technologies. Forty-five participants successfully finished the study protocol (20 males, 25 females; 32 (11.48) years). ANOVAs showed large effect significant interactions between pressure levels and the percentage of full craniocervical flexion ROM when considering the 6 pressure reference levels of the CCFT (p < 0.001; η(2) = 0.697), 11 pressure levels separated by 1 mmHg (p < 0.001; η(2) = 0.683), and 21 pressure levels separated by 0.5 mmHg (p < 0.001; η(2) = 0.671). The novel time synchronizing system seems a feasible option to provide real-time monitoring of both pressure and ROM, which could serve as reference targets to further investigate the potential use of inertial sensor technology to assess or train deep cervical flexors.
format Online
Article
Text
id pubmed-10141233
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-101412332023-04-29 Potential Use of Wearable Inertial Sensors to Assess and Train Deep Cervical Flexors: A Feasibility Study with Real Time Synchronization of Kinematic and Pressure Data during the Craniocervical Flexion Test Bocos-Corredor, Elena Pérez-Fernández, Tomás Perez-Dominguez, Raquel Liébana, Sonia Armijo-Olivo, Susan Raya, Rafael Martin-Pintado-Zugasti, Aitor Sensors (Basel) Article The aim of the study was to develop a novel real-time, computer-based synchronization system to continuously record pressure and craniocervical flexion ROM (range of motion) during the CCFT (craniocervical flexion test) in order to assess its feasibility for measuring and discriminating the values of ROM between different pressure levels. This was a descriptive, observational, cross-sectional, feasibility study. Participants performed a full-range craniocervical flexion and the CCFT. During the CCFT, a pressure sensor and a wireless inertial sensor simultaneously registered data of pressure and ROM. A web application was developed using HTML and NodeJS technologies. Forty-five participants successfully finished the study protocol (20 males, 25 females; 32 (11.48) years). ANOVAs showed large effect significant interactions between pressure levels and the percentage of full craniocervical flexion ROM when considering the 6 pressure reference levels of the CCFT (p < 0.001; η(2) = 0.697), 11 pressure levels separated by 1 mmHg (p < 0.001; η(2) = 0.683), and 21 pressure levels separated by 0.5 mmHg (p < 0.001; η(2) = 0.671). The novel time synchronizing system seems a feasible option to provide real-time monitoring of both pressure and ROM, which could serve as reference targets to further investigate the potential use of inertial sensor technology to assess or train deep cervical flexors. MDPI 2023-04-12 /pmc/articles/PMC10141233/ /pubmed/37112252 http://dx.doi.org/10.3390/s23083911 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bocos-Corredor, Elena
Pérez-Fernández, Tomás
Perez-Dominguez, Raquel
Liébana, Sonia
Armijo-Olivo, Susan
Raya, Rafael
Martin-Pintado-Zugasti, Aitor
Potential Use of Wearable Inertial Sensors to Assess and Train Deep Cervical Flexors: A Feasibility Study with Real Time Synchronization of Kinematic and Pressure Data during the Craniocervical Flexion Test
title Potential Use of Wearable Inertial Sensors to Assess and Train Deep Cervical Flexors: A Feasibility Study with Real Time Synchronization of Kinematic and Pressure Data during the Craniocervical Flexion Test
title_full Potential Use of Wearable Inertial Sensors to Assess and Train Deep Cervical Flexors: A Feasibility Study with Real Time Synchronization of Kinematic and Pressure Data during the Craniocervical Flexion Test
title_fullStr Potential Use of Wearable Inertial Sensors to Assess and Train Deep Cervical Flexors: A Feasibility Study with Real Time Synchronization of Kinematic and Pressure Data during the Craniocervical Flexion Test
title_full_unstemmed Potential Use of Wearable Inertial Sensors to Assess and Train Deep Cervical Flexors: A Feasibility Study with Real Time Synchronization of Kinematic and Pressure Data during the Craniocervical Flexion Test
title_short Potential Use of Wearable Inertial Sensors to Assess and Train Deep Cervical Flexors: A Feasibility Study with Real Time Synchronization of Kinematic and Pressure Data during the Craniocervical Flexion Test
title_sort potential use of wearable inertial sensors to assess and train deep cervical flexors: a feasibility study with real time synchronization of kinematic and pressure data during the craniocervical flexion test
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10141233/
https://www.ncbi.nlm.nih.gov/pubmed/37112252
http://dx.doi.org/10.3390/s23083911
work_keys_str_mv AT bocoscorredorelena potentialuseofwearableinertialsensorstoassessandtraindeepcervicalflexorsafeasibilitystudywithrealtimesynchronizationofkinematicandpressuredataduringthecraniocervicalflexiontest
AT perezfernandeztomas potentialuseofwearableinertialsensorstoassessandtraindeepcervicalflexorsafeasibilitystudywithrealtimesynchronizationofkinematicandpressuredataduringthecraniocervicalflexiontest
AT perezdominguezraquel potentialuseofwearableinertialsensorstoassessandtraindeepcervicalflexorsafeasibilitystudywithrealtimesynchronizationofkinematicandpressuredataduringthecraniocervicalflexiontest
AT liebanasonia potentialuseofwearableinertialsensorstoassessandtraindeepcervicalflexorsafeasibilitystudywithrealtimesynchronizationofkinematicandpressuredataduringthecraniocervicalflexiontest
AT armijoolivosusan potentialuseofwearableinertialsensorstoassessandtraindeepcervicalflexorsafeasibilitystudywithrealtimesynchronizationofkinematicandpressuredataduringthecraniocervicalflexiontest
AT rayarafael potentialuseofwearableinertialsensorstoassessandtraindeepcervicalflexorsafeasibilitystudywithrealtimesynchronizationofkinematicandpressuredataduringthecraniocervicalflexiontest
AT martinpintadozugastiaitor potentialuseofwearableinertialsensorstoassessandtraindeepcervicalflexorsafeasibilitystudywithrealtimesynchronizationofkinematicandpressuredataduringthecraniocervicalflexiontest