Compact Back-End Electronics with Temperature Compensation and Efficient Data Management for In Situ SiPM-Based Radiation Detection

A compact back-end interface for silicon photomultipliers (SiPMs) implementing Zener diode-based temperature compensation has been developed for the remote detection of beta and gamma radiation. Remote detection is facilitated by the development of an efficient data management system utilising MySQL...

Descripción completa

Detalles Bibliográficos
Autores principales: Dixon, Nile E. J., Monk, Stephen D., Graham, James, Cheneler, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10141715/
https://www.ncbi.nlm.nih.gov/pubmed/37112392
http://dx.doi.org/10.3390/s23084053
_version_ 1785033445228937216
author Dixon, Nile E. J.
Monk, Stephen D.
Graham, James
Cheneler, David
author_facet Dixon, Nile E. J.
Monk, Stephen D.
Graham, James
Cheneler, David
author_sort Dixon, Nile E. J.
collection PubMed
description A compact back-end interface for silicon photomultipliers (SiPMs) implementing Zener diode-based temperature compensation has been developed for the remote detection of beta and gamma radiation. Remote detection is facilitated by the development of an efficient data management system utilising MySQL database storage for recording periodic spectra data for wireless access over a private Wi-Fi network. A trapezoidal peak shaping algorithm has been implemented on an FPGA for the continuous conversation of pulses from the SiPM, signifying the detection of a radiological particle, into spectra. This system has been designed to fit within a 46 mm cylindrical diameter for in situ characterization, and can be attached to one or more SiPMs used in conjunction with a range of scintillators. LED blink tests have been used to optimise the trapezoidal shaper coefficients to maximise the resolution of the recorded spectra. Experiments with an array of SiPMs integrated with a NaI(Tl) scintillator exposed to sealed sources of Co-60, Cs-137, Na-22 and Am-241 have shown that the detector achieves a peak efficiency of 27.09 ± 0.13% for a gamma peak at 59.54 keV produced by Am-241, and a minimum energy resolution (Delta E/E) of 4.27 ± 1.16% for the 1332.5 keV gamma peak from Co-60.
format Online
Article
Text
id pubmed-10141715
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-101417152023-04-29 Compact Back-End Electronics with Temperature Compensation and Efficient Data Management for In Situ SiPM-Based Radiation Detection Dixon, Nile E. J. Monk, Stephen D. Graham, James Cheneler, David Sensors (Basel) Article A compact back-end interface for silicon photomultipliers (SiPMs) implementing Zener diode-based temperature compensation has been developed for the remote detection of beta and gamma radiation. Remote detection is facilitated by the development of an efficient data management system utilising MySQL database storage for recording periodic spectra data for wireless access over a private Wi-Fi network. A trapezoidal peak shaping algorithm has been implemented on an FPGA for the continuous conversation of pulses from the SiPM, signifying the detection of a radiological particle, into spectra. This system has been designed to fit within a 46 mm cylindrical diameter for in situ characterization, and can be attached to one or more SiPMs used in conjunction with a range of scintillators. LED blink tests have been used to optimise the trapezoidal shaper coefficients to maximise the resolution of the recorded spectra. Experiments with an array of SiPMs integrated with a NaI(Tl) scintillator exposed to sealed sources of Co-60, Cs-137, Na-22 and Am-241 have shown that the detector achieves a peak efficiency of 27.09 ± 0.13% for a gamma peak at 59.54 keV produced by Am-241, and a minimum energy resolution (Delta E/E) of 4.27 ± 1.16% for the 1332.5 keV gamma peak from Co-60. MDPI 2023-04-17 /pmc/articles/PMC10141715/ /pubmed/37112392 http://dx.doi.org/10.3390/s23084053 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dixon, Nile E. J.
Monk, Stephen D.
Graham, James
Cheneler, David
Compact Back-End Electronics with Temperature Compensation and Efficient Data Management for In Situ SiPM-Based Radiation Detection
title Compact Back-End Electronics with Temperature Compensation and Efficient Data Management for In Situ SiPM-Based Radiation Detection
title_full Compact Back-End Electronics with Temperature Compensation and Efficient Data Management for In Situ SiPM-Based Radiation Detection
title_fullStr Compact Back-End Electronics with Temperature Compensation and Efficient Data Management for In Situ SiPM-Based Radiation Detection
title_full_unstemmed Compact Back-End Electronics with Temperature Compensation and Efficient Data Management for In Situ SiPM-Based Radiation Detection
title_short Compact Back-End Electronics with Temperature Compensation and Efficient Data Management for In Situ SiPM-Based Radiation Detection
title_sort compact back-end electronics with temperature compensation and efficient data management for in situ sipm-based radiation detection
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10141715/
https://www.ncbi.nlm.nih.gov/pubmed/37112392
http://dx.doi.org/10.3390/s23084053
work_keys_str_mv AT dixonnileej compactbackendelectronicswithtemperaturecompensationandefficientdatamanagementforinsitusipmbasedradiationdetection
AT monkstephend compactbackendelectronicswithtemperaturecompensationandefficientdatamanagementforinsitusipmbasedradiationdetection
AT grahamjames compactbackendelectronicswithtemperaturecompensationandefficientdatamanagementforinsitusipmbasedradiationdetection
AT chenelerdavid compactbackendelectronicswithtemperaturecompensationandefficientdatamanagementforinsitusipmbasedradiationdetection