Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection
Background: Radiological high-resolution computed tomography-based evaluation of cochlear implant candidates’ cochlear duct length (CDL) has become the method of choice for electrode array selection. The aim of the present study was to evaluate if MRI-based data match CT-based data and if this impac...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10142378/ https://www.ncbi.nlm.nih.gov/pubmed/37109019 http://dx.doi.org/10.3390/jpm13040633 |
_version_ | 1785033599074959360 |
---|---|
author | Thomas, Jan Peter Klein, Hannah Haubitz, Imme Dazert, Stefan Völter, Christiane |
author_facet | Thomas, Jan Peter Klein, Hannah Haubitz, Imme Dazert, Stefan Völter, Christiane |
author_sort | Thomas, Jan Peter |
collection | PubMed |
description | Background: Radiological high-resolution computed tomography-based evaluation of cochlear implant candidates’ cochlear duct length (CDL) has become the method of choice for electrode array selection. The aim of the present study was to evaluate if MRI-based data match CT-based data and if this impacts on electrode array choice. Methods: Participants were 39 children. CDL, length at two turns, diameters, and height of the cochlea were determined via CT and MRI by three raters using tablet-based otosurgical planning software. Personalized electrode array length, angular insertion depth (AID), intra- and interrater differences, and reliability were calculated. Results: Mean intrarater difference of CT- versus MRI-based CDL was 0.528 ± 0.483 mm without significant differences. Individual length at two turns differed between 28.0 mm and 36.6 mm. Intrarater reliability between CT versus MRI measurements was high (intra-class correlation coefficient (ICC): 0.929–0.938). Selection of the optimal electrode array based on CT and MRI matched in 90.1% of cases. Mean AID was 629.5° based on the CT and 634.6° based on the MRI; this is not a significant difference. ICC of the mean interrater reliability was 0.887 for the CT-based evaluation and 0.82 for the MRI-based evaluation. Conclusion: MRI-based CDL measurement shows a low intrarater difference and a high interrater reliability and is therefore suitable for personalized electrode array selection. |
format | Online Article Text |
id | pubmed-10142378 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-101423782023-04-29 Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection Thomas, Jan Peter Klein, Hannah Haubitz, Imme Dazert, Stefan Völter, Christiane J Pers Med Article Background: Radiological high-resolution computed tomography-based evaluation of cochlear implant candidates’ cochlear duct length (CDL) has become the method of choice for electrode array selection. The aim of the present study was to evaluate if MRI-based data match CT-based data and if this impacts on electrode array choice. Methods: Participants were 39 children. CDL, length at two turns, diameters, and height of the cochlea were determined via CT and MRI by three raters using tablet-based otosurgical planning software. Personalized electrode array length, angular insertion depth (AID), intra- and interrater differences, and reliability were calculated. Results: Mean intrarater difference of CT- versus MRI-based CDL was 0.528 ± 0.483 mm without significant differences. Individual length at two turns differed between 28.0 mm and 36.6 mm. Intrarater reliability between CT versus MRI measurements was high (intra-class correlation coefficient (ICC): 0.929–0.938). Selection of the optimal electrode array based on CT and MRI matched in 90.1% of cases. Mean AID was 629.5° based on the CT and 634.6° based on the MRI; this is not a significant difference. ICC of the mean interrater reliability was 0.887 for the CT-based evaluation and 0.82 for the MRI-based evaluation. Conclusion: MRI-based CDL measurement shows a low intrarater difference and a high interrater reliability and is therefore suitable for personalized electrode array selection. MDPI 2023-04-04 /pmc/articles/PMC10142378/ /pubmed/37109019 http://dx.doi.org/10.3390/jpm13040633 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Thomas, Jan Peter Klein, Hannah Haubitz, Imme Dazert, Stefan Völter, Christiane Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection |
title | Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection |
title_full | Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection |
title_fullStr | Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection |
title_full_unstemmed | Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection |
title_short | Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection |
title_sort | intra- and interrater reliability of ct- versus mri-based cochlear duct length measurement in pediatric cochlear implant candidates and its impact on personalized electrode array selection |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10142378/ https://www.ncbi.nlm.nih.gov/pubmed/37109019 http://dx.doi.org/10.3390/jpm13040633 |
work_keys_str_mv | AT thomasjanpeter intraandinterraterreliabilityofctversusmribasedcochlearductlengthmeasurementinpediatriccochlearimplantcandidatesanditsimpactonpersonalizedelectrodearrayselection AT kleinhannah intraandinterraterreliabilityofctversusmribasedcochlearductlengthmeasurementinpediatriccochlearimplantcandidatesanditsimpactonpersonalizedelectrodearrayselection AT haubitzimme intraandinterraterreliabilityofctversusmribasedcochlearductlengthmeasurementinpediatriccochlearimplantcandidatesanditsimpactonpersonalizedelectrodearrayselection AT dazertstefan intraandinterraterreliabilityofctversusmribasedcochlearductlengthmeasurementinpediatriccochlearimplantcandidatesanditsimpactonpersonalizedelectrodearrayselection AT volterchristiane intraandinterraterreliabilityofctversusmribasedcochlearductlengthmeasurementinpediatriccochlearimplantcandidatesanditsimpactonpersonalizedelectrodearrayselection |