Cargando…

Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection

Background: Radiological high-resolution computed tomography-based evaluation of cochlear implant candidates’ cochlear duct length (CDL) has become the method of choice for electrode array selection. The aim of the present study was to evaluate if MRI-based data match CT-based data and if this impac...

Descripción completa

Detalles Bibliográficos
Autores principales: Thomas, Jan Peter, Klein, Hannah, Haubitz, Imme, Dazert, Stefan, Völter, Christiane
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10142378/
https://www.ncbi.nlm.nih.gov/pubmed/37109019
http://dx.doi.org/10.3390/jpm13040633
_version_ 1785033599074959360
author Thomas, Jan Peter
Klein, Hannah
Haubitz, Imme
Dazert, Stefan
Völter, Christiane
author_facet Thomas, Jan Peter
Klein, Hannah
Haubitz, Imme
Dazert, Stefan
Völter, Christiane
author_sort Thomas, Jan Peter
collection PubMed
description Background: Radiological high-resolution computed tomography-based evaluation of cochlear implant candidates’ cochlear duct length (CDL) has become the method of choice for electrode array selection. The aim of the present study was to evaluate if MRI-based data match CT-based data and if this impacts on electrode array choice. Methods: Participants were 39 children. CDL, length at two turns, diameters, and height of the cochlea were determined via CT and MRI by three raters using tablet-based otosurgical planning software. Personalized electrode array length, angular insertion depth (AID), intra- and interrater differences, and reliability were calculated. Results: Mean intrarater difference of CT- versus MRI-based CDL was 0.528 ± 0.483 mm without significant differences. Individual length at two turns differed between 28.0 mm and 36.6 mm. Intrarater reliability between CT versus MRI measurements was high (intra-class correlation coefficient (ICC): 0.929–0.938). Selection of the optimal electrode array based on CT and MRI matched in 90.1% of cases. Mean AID was 629.5° based on the CT and 634.6° based on the MRI; this is not a significant difference. ICC of the mean interrater reliability was 0.887 for the CT-based evaluation and 0.82 for the MRI-based evaluation. Conclusion: MRI-based CDL measurement shows a low intrarater difference and a high interrater reliability and is therefore suitable for personalized electrode array selection.
format Online
Article
Text
id pubmed-10142378
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-101423782023-04-29 Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection Thomas, Jan Peter Klein, Hannah Haubitz, Imme Dazert, Stefan Völter, Christiane J Pers Med Article Background: Radiological high-resolution computed tomography-based evaluation of cochlear implant candidates’ cochlear duct length (CDL) has become the method of choice for electrode array selection. The aim of the present study was to evaluate if MRI-based data match CT-based data and if this impacts on electrode array choice. Methods: Participants were 39 children. CDL, length at two turns, diameters, and height of the cochlea were determined via CT and MRI by three raters using tablet-based otosurgical planning software. Personalized electrode array length, angular insertion depth (AID), intra- and interrater differences, and reliability were calculated. Results: Mean intrarater difference of CT- versus MRI-based CDL was 0.528 ± 0.483 mm without significant differences. Individual length at two turns differed between 28.0 mm and 36.6 mm. Intrarater reliability between CT versus MRI measurements was high (intra-class correlation coefficient (ICC): 0.929–0.938). Selection of the optimal electrode array based on CT and MRI matched in 90.1% of cases. Mean AID was 629.5° based on the CT and 634.6° based on the MRI; this is not a significant difference. ICC of the mean interrater reliability was 0.887 for the CT-based evaluation and 0.82 for the MRI-based evaluation. Conclusion: MRI-based CDL measurement shows a low intrarater difference and a high interrater reliability and is therefore suitable for personalized electrode array selection. MDPI 2023-04-04 /pmc/articles/PMC10142378/ /pubmed/37109019 http://dx.doi.org/10.3390/jpm13040633 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Thomas, Jan Peter
Klein, Hannah
Haubitz, Imme
Dazert, Stefan
Völter, Christiane
Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection
title Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection
title_full Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection
title_fullStr Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection
title_full_unstemmed Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection
title_short Intra- and Interrater Reliability of CT- versus MRI-Based Cochlear Duct Length Measurement in Pediatric Cochlear Implant Candidates and Its Impact on Personalized Electrode Array Selection
title_sort intra- and interrater reliability of ct- versus mri-based cochlear duct length measurement in pediatric cochlear implant candidates and its impact on personalized electrode array selection
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10142378/
https://www.ncbi.nlm.nih.gov/pubmed/37109019
http://dx.doi.org/10.3390/jpm13040633
work_keys_str_mv AT thomasjanpeter intraandinterraterreliabilityofctversusmribasedcochlearductlengthmeasurementinpediatriccochlearimplantcandidatesanditsimpactonpersonalizedelectrodearrayselection
AT kleinhannah intraandinterraterreliabilityofctversusmribasedcochlearductlengthmeasurementinpediatriccochlearimplantcandidatesanditsimpactonpersonalizedelectrodearrayselection
AT haubitzimme intraandinterraterreliabilityofctversusmribasedcochlearductlengthmeasurementinpediatriccochlearimplantcandidatesanditsimpactonpersonalizedelectrodearrayselection
AT dazertstefan intraandinterraterreliabilityofctversusmribasedcochlearductlengthmeasurementinpediatriccochlearimplantcandidatesanditsimpactonpersonalizedelectrodearrayselection
AT volterchristiane intraandinterraterreliabilityofctversusmribasedcochlearductlengthmeasurementinpediatriccochlearimplantcandidatesanditsimpactonpersonalizedelectrodearrayselection