Cargando…
An Engineering Method for Resonant Microcantilever Using Double-Channel Excitation and Signal Acquisition Based on LabVIEW
Resonant microcantilevers have the advantages of ultra-high heating rates, analysis speed, ultra-low power consumption, temperature programming, and trace sample analysis when applied in TGA. However, the current single-channel testing system for resonant microcantilevers can only detect one sample...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10142883/ https://www.ncbi.nlm.nih.gov/pubmed/37421056 http://dx.doi.org/10.3390/mi14040823 |
_version_ | 1785033718995353600 |
---|---|
author | Wang, Shanlai Cao, Zhi Zhang, Xiaoyang Yu, Haitao Yao, Lei |
author_facet | Wang, Shanlai Cao, Zhi Zhang, Xiaoyang Yu, Haitao Yao, Lei |
author_sort | Wang, Shanlai |
collection | PubMed |
description | Resonant microcantilevers have the advantages of ultra-high heating rates, analysis speed, ultra-low power consumption, temperature programming, and trace sample analysis when applied in TGA. However, the current single-channel testing system for resonant microcantilevers can only detect one sample at a time, and need two program heating tests to obtain the thermogravimetric curve of a sample. In many cases, it is desirable to obtain the thermogravimetric curve of a sample with a single-program heating test and to simultaneously detect multiple microcantilevers for testing multiple samples. To address this issue, this paper proposes a dual-channel testing method, where a microcantilever is used as a control group and another microcantilever is used as an experimental group, to obtain the thermal weight curve of the sample in a single program temperature ramp test. With the help of the LabVIEW’s convenient parallel running method, the functionality of simultaneously detecting two microcantilevers is achieved. Experimental validation showed that this dual-channel testing system can obtain the thermogravimetric curve of a sample with a single program heating test and detect two types of samples simultaneously. |
format | Online Article Text |
id | pubmed-10142883 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-101428832023-04-29 An Engineering Method for Resonant Microcantilever Using Double-Channel Excitation and Signal Acquisition Based on LabVIEW Wang, Shanlai Cao, Zhi Zhang, Xiaoyang Yu, Haitao Yao, Lei Micromachines (Basel) Article Resonant microcantilevers have the advantages of ultra-high heating rates, analysis speed, ultra-low power consumption, temperature programming, and trace sample analysis when applied in TGA. However, the current single-channel testing system for resonant microcantilevers can only detect one sample at a time, and need two program heating tests to obtain the thermogravimetric curve of a sample. In many cases, it is desirable to obtain the thermogravimetric curve of a sample with a single-program heating test and to simultaneously detect multiple microcantilevers for testing multiple samples. To address this issue, this paper proposes a dual-channel testing method, where a microcantilever is used as a control group and another microcantilever is used as an experimental group, to obtain the thermal weight curve of the sample in a single program temperature ramp test. With the help of the LabVIEW’s convenient parallel running method, the functionality of simultaneously detecting two microcantilevers is achieved. Experimental validation showed that this dual-channel testing system can obtain the thermogravimetric curve of a sample with a single program heating test and detect two types of samples simultaneously. MDPI 2023-04-07 /pmc/articles/PMC10142883/ /pubmed/37421056 http://dx.doi.org/10.3390/mi14040823 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wang, Shanlai Cao, Zhi Zhang, Xiaoyang Yu, Haitao Yao, Lei An Engineering Method for Resonant Microcantilever Using Double-Channel Excitation and Signal Acquisition Based on LabVIEW |
title | An Engineering Method for Resonant Microcantilever Using Double-Channel Excitation and Signal Acquisition Based on LabVIEW |
title_full | An Engineering Method for Resonant Microcantilever Using Double-Channel Excitation and Signal Acquisition Based on LabVIEW |
title_fullStr | An Engineering Method for Resonant Microcantilever Using Double-Channel Excitation and Signal Acquisition Based on LabVIEW |
title_full_unstemmed | An Engineering Method for Resonant Microcantilever Using Double-Channel Excitation and Signal Acquisition Based on LabVIEW |
title_short | An Engineering Method for Resonant Microcantilever Using Double-Channel Excitation and Signal Acquisition Based on LabVIEW |
title_sort | engineering method for resonant microcantilever using double-channel excitation and signal acquisition based on labview |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10142883/ https://www.ncbi.nlm.nih.gov/pubmed/37421056 http://dx.doi.org/10.3390/mi14040823 |
work_keys_str_mv | AT wangshanlai anengineeringmethodforresonantmicrocantileverusingdoublechannelexcitationandsignalacquisitionbasedonlabview AT caozhi anengineeringmethodforresonantmicrocantileverusingdoublechannelexcitationandsignalacquisitionbasedonlabview AT zhangxiaoyang anengineeringmethodforresonantmicrocantileverusingdoublechannelexcitationandsignalacquisitionbasedonlabview AT yuhaitao anengineeringmethodforresonantmicrocantileverusingdoublechannelexcitationandsignalacquisitionbasedonlabview AT yaolei anengineeringmethodforresonantmicrocantileverusingdoublechannelexcitationandsignalacquisitionbasedonlabview AT wangshanlai engineeringmethodforresonantmicrocantileverusingdoublechannelexcitationandsignalacquisitionbasedonlabview AT caozhi engineeringmethodforresonantmicrocantileverusingdoublechannelexcitationandsignalacquisitionbasedonlabview AT zhangxiaoyang engineeringmethodforresonantmicrocantileverusingdoublechannelexcitationandsignalacquisitionbasedonlabview AT yuhaitao engineeringmethodforresonantmicrocantileverusingdoublechannelexcitationandsignalacquisitionbasedonlabview AT yaolei engineeringmethodforresonantmicrocantileverusingdoublechannelexcitationandsignalacquisitionbasedonlabview |