Cargando…

Risk Factors Associated with Intraoperative Iatrogenic Fracture in Patients Undergoing Intramedullary Nailing for Atypical Femoral Fractures with Marked Anterior and Lateral Bowing

Background and objectives: Iatrogenic fractures are potential complications during intramedullary (IM) nailing for atypical femoral fractures (AFFs). The risk factors associated with iatrogenic fractures remain unclear, although excessive femoral bowing and osteoporosis are hypothesized to be contri...

Descripción completa

Detalles Bibliográficos
Autores principales: Joo, Yong Bum, Jeon, Yoo Sun, Lee, Woo Yong, Chung, Hyung Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10143868/
https://www.ncbi.nlm.nih.gov/pubmed/37109693
http://dx.doi.org/10.3390/medicina59040735
_version_ 1785033962803953664
author Joo, Yong Bum
Jeon, Yoo Sun
Lee, Woo Yong
Chung, Hyung Jin
author_facet Joo, Yong Bum
Jeon, Yoo Sun
Lee, Woo Yong
Chung, Hyung Jin
author_sort Joo, Yong Bum
collection PubMed
description Background and objectives: Iatrogenic fractures are potential complications during intramedullary (IM) nailing for atypical femoral fractures (AFFs). The risk factors associated with iatrogenic fractures remain unclear, although excessive femoral bowing and osteoporosis are hypothesized to be contributing factors. The present study aimed to determine the risk factors for the occurrence of iatrogenic fractures during IM nailing in patients with AFFs. Materials and Methods: This retrospective cross-sectional study evaluated 95 patients with AFF (all female; age range: 49–87 years) who underwent IM nailing between June 2008 and December 2017. The patients were divided into two groups: Group I (with iatrogenic fracture: n = 20) and Group II (without iatrogenic fracture: n = 75). Background characteristics were retrieved from medical records and radiographic measurements were obtained. Univariate and multivariate logistic regression analyses were performed to identify risk factors for the occurrence of intraoperative iatrogenic fractures. Receiver operating curve (ROC) analysis was conducted to determine a cut-off value for the prediction of iatrogenic fracture occurrence. Results: Iatrogenic fractures occurred in 20 (21.1%) patients. The two groups exhibited no significant differences regarding age and other background characteristics. Group I exhibited significantly lower mean femoral bone mineral density (BMD) and significantly greater mean lateral and anterior femoral bowing angles than Group II (all p < 0.05). There were no significant differences in AFF location, nonunion, and IM nail diameter, length, or nail entry point between the two groups. In the univariate analysis, femoral BMD and lateral bowing of the femur differed significantly between the two groups. On multivariate analysis, only lateral bowing of the femur remained significantly associated with iatrogenic fracture occurrence. The ROC analysis determined a cut-off value of 9.3° in lateral bowing of the femur for prediction of iatrogenic fracture occurrence during IM nailing for AFF treatment. Conclusions: The lateral bowing angle of the femur is an important predictive factor for intraoperative iatrogenic fracture occurrence in patients undergoing IM nailing for AFF treatment.
format Online
Article
Text
id pubmed-10143868
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-101438682023-04-29 Risk Factors Associated with Intraoperative Iatrogenic Fracture in Patients Undergoing Intramedullary Nailing for Atypical Femoral Fractures with Marked Anterior and Lateral Bowing Joo, Yong Bum Jeon, Yoo Sun Lee, Woo Yong Chung, Hyung Jin Medicina (Kaunas) Article Background and objectives: Iatrogenic fractures are potential complications during intramedullary (IM) nailing for atypical femoral fractures (AFFs). The risk factors associated with iatrogenic fractures remain unclear, although excessive femoral bowing and osteoporosis are hypothesized to be contributing factors. The present study aimed to determine the risk factors for the occurrence of iatrogenic fractures during IM nailing in patients with AFFs. Materials and Methods: This retrospective cross-sectional study evaluated 95 patients with AFF (all female; age range: 49–87 years) who underwent IM nailing between June 2008 and December 2017. The patients were divided into two groups: Group I (with iatrogenic fracture: n = 20) and Group II (without iatrogenic fracture: n = 75). Background characteristics were retrieved from medical records and radiographic measurements were obtained. Univariate and multivariate logistic regression analyses were performed to identify risk factors for the occurrence of intraoperative iatrogenic fractures. Receiver operating curve (ROC) analysis was conducted to determine a cut-off value for the prediction of iatrogenic fracture occurrence. Results: Iatrogenic fractures occurred in 20 (21.1%) patients. The two groups exhibited no significant differences regarding age and other background characteristics. Group I exhibited significantly lower mean femoral bone mineral density (BMD) and significantly greater mean lateral and anterior femoral bowing angles than Group II (all p < 0.05). There were no significant differences in AFF location, nonunion, and IM nail diameter, length, or nail entry point between the two groups. In the univariate analysis, femoral BMD and lateral bowing of the femur differed significantly between the two groups. On multivariate analysis, only lateral bowing of the femur remained significantly associated with iatrogenic fracture occurrence. The ROC analysis determined a cut-off value of 9.3° in lateral bowing of the femur for prediction of iatrogenic fracture occurrence during IM nailing for AFF treatment. Conclusions: The lateral bowing angle of the femur is an important predictive factor for intraoperative iatrogenic fracture occurrence in patients undergoing IM nailing for AFF treatment. MDPI 2023-04-09 /pmc/articles/PMC10143868/ /pubmed/37109693 http://dx.doi.org/10.3390/medicina59040735 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Joo, Yong Bum
Jeon, Yoo Sun
Lee, Woo Yong
Chung, Hyung Jin
Risk Factors Associated with Intraoperative Iatrogenic Fracture in Patients Undergoing Intramedullary Nailing for Atypical Femoral Fractures with Marked Anterior and Lateral Bowing
title Risk Factors Associated with Intraoperative Iatrogenic Fracture in Patients Undergoing Intramedullary Nailing for Atypical Femoral Fractures with Marked Anterior and Lateral Bowing
title_full Risk Factors Associated with Intraoperative Iatrogenic Fracture in Patients Undergoing Intramedullary Nailing for Atypical Femoral Fractures with Marked Anterior and Lateral Bowing
title_fullStr Risk Factors Associated with Intraoperative Iatrogenic Fracture in Patients Undergoing Intramedullary Nailing for Atypical Femoral Fractures with Marked Anterior and Lateral Bowing
title_full_unstemmed Risk Factors Associated with Intraoperative Iatrogenic Fracture in Patients Undergoing Intramedullary Nailing for Atypical Femoral Fractures with Marked Anterior and Lateral Bowing
title_short Risk Factors Associated with Intraoperative Iatrogenic Fracture in Patients Undergoing Intramedullary Nailing for Atypical Femoral Fractures with Marked Anterior and Lateral Bowing
title_sort risk factors associated with intraoperative iatrogenic fracture in patients undergoing intramedullary nailing for atypical femoral fractures with marked anterior and lateral bowing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10143868/
https://www.ncbi.nlm.nih.gov/pubmed/37109693
http://dx.doi.org/10.3390/medicina59040735
work_keys_str_mv AT jooyongbum riskfactorsassociatedwithintraoperativeiatrogenicfractureinpatientsundergoingintramedullarynailingforatypicalfemoralfractureswithmarkedanteriorandlateralbowing
AT jeonyoosun riskfactorsassociatedwithintraoperativeiatrogenicfractureinpatientsundergoingintramedullarynailingforatypicalfemoralfractureswithmarkedanteriorandlateralbowing
AT leewooyong riskfactorsassociatedwithintraoperativeiatrogenicfractureinpatientsundergoingintramedullarynailingforatypicalfemoralfractureswithmarkedanteriorandlateralbowing
AT chunghyungjin riskfactorsassociatedwithintraoperativeiatrogenicfractureinpatientsundergoingintramedullarynailingforatypicalfemoralfractureswithmarkedanteriorandlateralbowing